• Title/Summary/Keyword: One Scan Method

Search Result 297, Processing Time 0.028 seconds

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.

A New Driving Scheme for Reduction of Addressing time and its Dispersion in AC PDP

  • Lee, Sung-Hyun;Kim, Dong-Hyun;Park, Cha-Soo;Park, Chung-Hoo;Ryu, Jae-Hwa
    • Journal of Information Display
    • /
    • v.2 no.2
    • /
    • pp.39-44
    • /
    • 2001
  • The conditions of the wall charges and priming particles in a unit discharge cell in AC PDP seriously affect the addressing discharge characteristics in the driving method with ramped setup pulse. Moreover, the discharge conditions at the end of the scan line may be different from the first scan line because of the difference of about 1ms address time. Consequently, the addressing time and its dispersion may be different for any two discharge cells that lead to misfiring and the increase in the total addressing time. In order to improve the addressing time and its dispersion, we have applied different addressing voltage at each cell such as progressively increase pulse voltage instead of constant one. As a result, the addressing time and its dispersion of all cells were improved by about 30% compared with the conventional driving method.

  • PDF

A New Algorithm of License Plate Location

  • Jin, Dan;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.108-110
    • /
    • 2004
  • Automatic license plate recognition (LPR) is one of the critical techniques of the intelligent transportation system (ITS), in which license plate location plays an important role. In this paper, through surveying the international existing techniques, a new method for locating license plate is proposed: utilize row scan method to locate up and down boundary of the plate; and based on the location of up and down boundary, take advantage of the feature of plate area to locate left and right boundary of the plate. The tests of using the proposed algorithms have been conducted. The experimental results show that the proposed approaches are reasonable and accurate.

  • PDF

Implementation of Ultrasonic Immersion Technique for Babbitt Metal Debonding in Turbine Bearing (초음파 수침법을 이용한 터빈베어링 Babbitt금속 박리 검사 기술)

  • Jung, Gye-Jo;Park, Sang-Ki;Cho, Yong-Sang;Park, Byung-Cheol;Kil, Doo-Song
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.348-353
    • /
    • 2004
  • This study is aimed for the implementation of ultrasonic method to assess the reliability of turbine bearings. A modified ultrasonic immersion technique was carried out in both laboratory experiment and field application. From the laboratory results, we confirmed that the condition of interface layer between the babbitt and base metal be monitored by the C-Scan. The C-scan image by the ultrasonic immersion test can be used successfully to observe the condition of interface layer. The testing with a focused transducer provides a promising approach for estimating the extent of the damaged region and observing the interface layer effectively. The difference of the ultrasonic reflection ratio between the bonding and debonding area at the interface layer is one of the key parameters for assessing the extent of the damaged area; additionally, the reflection amplitude exhibits a favorable correlation with the overall damage level. The technique developed in this study was applied to the inspection of the turbine bearings at several power plants in Korea whereby the applicability in the field can be ascertained.

Study on Tensile Properties of AlSi10Mg produced by Selective Laser Melting (SLM 공정 기법으로 제작한 AlSi10Mg 인장특성에 관한 연구)

  • Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.25-31
    • /
    • 2018
  • Selective Laser Melting is one of the representative 3D printing techniques for handling metal materials. The main factors influencing the characteristics of structures fabricated by the SLM method include the build-up angle of structures, laser power, laser scan speed, and scan spacing. In this study, the tensile properties of AlSi10Mg alloys were investigated by considering the build-up angle of tensile test specimens, laser scanning speed and scan spacing as variables. The yield stress, tensile strength, and elongation were considered as tensile properties. From the test results, it was confirmed that the yield stress values were lowered in the order of 0, 45, and 90 based on the manufacturing direction of the tensile specimen. The maximum yield stress value was obtained at 1870 mm / min based on the laser scan speed. The yield stress size decreased with decreasing scan speed. Based on the laser scan spacing, as the value increases, the yield stress increases, but the variation is smaller than the other test criteria. The tendency of the tensile strength and elongation variation depending on the test conditions was difficult to understand.

The Usefulness of Measurement of Whole Body Count in Assessing Bone Marrow Metastasis in Cancer Patients with Increased Periarticular Bone Uptake on Follow-up Bone Scan: A Comparison with Bone Marrow Scan (암환자의 추적 골스캔에서 관절주위 섭취증가시 전신골섭취계수 측정이 골수전이 평가에 도움이 되는가-골수스캔과의 비교)

  • Jin, Seong-Chan;Choi, Yun-Young;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.428-436
    • /
    • 2003
  • Purpose: Increased periarticular uptake could be associated with peripheral bone marrow expansion in cancer patients with axial bone marrow metastasis. We compared bone scan and bone marrow scan to investigate whether the increased whole body count in patients with increased periarticular uptake on bone scan is useful in the diagnosis of axial marrow metastasis, and evaluate the role of additional bone marrow scan in these cases. Materials and methods: Twelve patients with malignant diseases who showed increased periarticular uptake on bone scan were included. Whole body count was measured on bone scan and it is considered to be increased when the count is more than twice of other patients. Bone marrow scan was taken within 3-7 days. Results: Five hematologic malignancy, 3 stomach cancer, 2 breast cancer, 1 prostate cancer and 1 lung cacner were included. All three patients with increased whole body count on bone scan showed axial marrow suppression and peripheral marrow expansion. Eight of 9 patients without increased whole body count showed axial marrow suppression and peripheral marrow expansion. One turned out to be blastic crisis of chronic myelogeneous leukemia, and seven showed normal axial marrow with peripheral marrow expansion in chronic anemia of malignancy. The last one without increased whole body count showed normal bone marrow scan finding. Conclusion: Increased whole body count on bone scan could be a clue to axial bone marrow metastasis in cancer patients with increased periarticular uptake, and bone marrow scan is a valuable method for differential diagnosis in these cases.

A study on Computer-controlled Ultrasonic Scanning Device (컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구)

  • Huh, H.;Park, C.S.;Hong, S.S.;Park, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

A selective sparse coding based fast super-resolution method for a side-scan sonar image (선택적 sparse coding 기반 측면주사 소나 영상의 고속 초해상도 복원 알고리즘)

  • Park, Jaihyun;Yang, Cheoljong;Ku, Bonwha;Lee, Seungho;Kim, Seongil;Ko, Hanseok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.1
    • /
    • pp.12-20
    • /
    • 2018
  • Efforts have been made to reconstruct low-resolution underwater images to high-resolution ones by using the image SR (Super-Resolution) method, all to improve efficiency when acquiring side-scan sonar images. As side-scan sonar images are similar with the optical images with respect to exploiting 2-dimensional signals, conventional image restoration methods for optical images can be considered as a solution. One of the most typical super-resolution methods for optical image is a sparse coding and there are studies for verifying applicability of sparse coding method for underwater images by analyzing sparsity of underwater images. Sparse coding is a method that obtains recovered signal from input signal by linear combination of dictionary and sparse coefficients. However, it requires huge computational load to accurately estimate sparse coefficients. In this study, a sparse coding based underwater image super-resolution method is applied while a selective reconstruction method for object region is suggested to reduce the processing time. For this method, this paper proposes an edge detection and object and non object region classification method for underwater images and combine it with sparse coding based image super-resolution method. Effectiveness of the proposed method is verified by reducing the processing time for image reconstruction over 32 % while preserving same level of PSNR (Peak Signal-to-Noise Ratio) compared with conventional method.

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

Frequent Patterns Mining using only one-time Database Scan (한 번의 데이터베이스 탐색에 의한 빈발항목집합 탐색)

  • Chai, Duck-Jin;Jin, Long;Lee, Yong-Mi;Hwang, Bu-Hyun;Ryu, Keun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.15D no.1
    • /
    • pp.15-22
    • /
    • 2008
  • In this paper, we propose an efficient algorithm using only one-time database scan. The proposed algorithm creates the bipartite graph which indicates relationship of large items and transactions including the large items. And then we can find large itemsets using the bipartite graph. The bipartite graph is generated when database is scanned to find large items. We can't easily find transactions which include large items in the large database. In the bipartite graph, large items and transactions are linked each other. So, we can trace the transactions which include large items through the link information. Therefore the bipartite graph is a indexed database which indicates inclusion relationship of large items and transactions. We can fast find large itemsets because proposed method conducts only one-time database scan and scans indexed the bipartite graph. Also, it don't generate candidate itemsets.