• Title/Summary/Keyword: Ondol Surface Temperature

Search Result 30, Processing Time 0.028 seconds

A Study on the Heat Pump-Latent Heat Storage Type (열펌프-잠열축열 온돌 시스템 연구)

  • 송현갑;박문수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.385-390
    • /
    • 2001
  • The Ondol system using both air-to-water heat pump and PCM(Phase Change Material) was constructed, and the effects of ambient air temperature on COP(Coefficient of Performance) of heat pump, the amount of heat supplied to the Ondol in the heating process, the heat storage in the PCM and the variation of Ondol room temperature were analyzed. The results from this study could be summarized as follows: 1. The COP of the heat pump (3 PS) was in proportion to the ambient air temperature. 2. When the ambient air temperature was varied between -10$^{\circ}C$ and -7$^{\circ}C$, the air temperature in the Ondol room was maintained between 16$^{\circ}C$ and 22$^{\circ}C$. As the results, it was certified that the heat pump-latent heat storage type Ondol system could be a comfortable residential heating system in the winter. 3. The maximum radiation and convection heat transfer from Ondol surface was 206.2 kJ/㎥hr and 82.6 kJ/㎥hr respectively. As the results, it could be confirmed that the radiation was major heat transfer mechanism for the Ondol room heating.

  • PDF

Thermoregulatory Responses in the Elderly and the Young under the Ondol System (온돌난방에서 노인과 청년의 피부온 반응 비교)

  • 정유정;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.149-158
    • /
    • 1998
  • The purpose of this study was to investigate the effect of age on the human thermoregulatory responses and to obtain the basic information of the Korean thermophysiological characteristics under the traditional Korean floor heating system-Ondol. The participants consisted of 10 elderly women, 4 elderly men(over 65 years), 10 young women and 5 young men(in twenties). They were exposed to temperature-controlled Ondol room(20$\pm$1$^{\circ}C$, 50$\pm$5%R.H., floor surface temperature: 30$\pm$1$^{\circ}C$) for 60 minutes and wore the same experimental clothing. The postures were performed sitting and supine on the floor. In each pose, rectal temperature, skin.temperature of 10 areas, mean skin temperature, clothing microclimate, body fat were measured. The results were as follows; 1. The rectal temperature gradually decreased and mean skin temperature gradually increased in young and old groups in both supine and sitting pose on heated Ondol floor for 60 minutes. 2. Rectal temperature was different in each pose. The rectal temperature decreased 0.1$^{\circ}C$ in both groups under the condition of sitting and decreased 0.2'c in elderly group under the condition of supine. In supine pose, elderly group was more declined than young group. Mean skin temperature increased 0.5$^{\circ}C$ in both poses, both groups.

  • PDF

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 -)

  • Sone, Hyun-Kap;Ryon, Young-Sun
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.13-28
    • /
    • 1995
  • In this study, the history of Korean traditional Ondol was investigated and the latent heat materials and bioceramics were selected to develop the latent heat storage-bioceramics Ondol system based on the Korean traditional Ondol(sensible heat storage type), and the thermal characteristics of Ondol were analyzed experimentally The results could be summarized as follows; 1. Korean traditional Ondol has been originated in "Whaduk" which had been utilized continuously for about $2{\times}10^6$ years from the Old Stone Age to the Bronze Age, and Korean traditional Ondol using in these days has been utilized for about 976 years from the Koryu Dynasty to the Modern Ages. 2. $Na_2SO_4{\cdot}10H_2O(SSD)$ was selected as latent heat material for the latent heat storage Ondol. 3. Ondol unit was filled with the latent heat material of 0.63 kg and the dimension of Ondol unit was $400mm{\times}400mm{\times}27mm(width{\t\imes}depth{\times}height)$. 4. The comfortable surface temperature($23{\sim}29^{\circ}C$) of the latent heat storage Ondol was lasted 5 hours at the room temperature of $16{\sim}18^{\circ}C$, whereas that of sensible heat storage Ondol was lasted only 1.0 hours in the same conditions. 5. For the thermal effect of bioceramics, the Ondol air temperature i.n case of bioceramics treatment on the pannel was higher than that of without bioceramics treatment.

  • PDF

Ondol Heating System Using Heat Pump - Comparison of Energy Consumption between the Heat Pump and the Oil Boiler - (열펌프를 이용한 온돌 난방 시스템 - 열펌프와 석유보일러의 소요에너지 비교 -)

  • 김현철;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.351-358
    • /
    • 1999
  • In these days, we are faced to a couple of difficult problems, the one is the unstable price of the energy due to the shortage of fossil fuel resources and the other is the serious environmental pollution from the excessive consumption of fossil fuel. In order to save the thermal energy for the house heating, in this study the heat pump using the natural thermal energy resources was provided for Ondol heating and the thermal energy consumption of the heat was compared to that of oil boiler. The results could be summarized as follows: 1. In the Ondol room the temperature difference between the Ondol surface and room air was about 5∼$10^{\circ}C$ in accordance with the ambient temperature. 2. The Ondol room heating efficiency of the heat pump with compressor of 2PS was the highest at the water flow rate of 200 l/h. 3. The energy saving rate of the heat pump to the oil boiler for heating the Ondol system was 19.3%. 4. The Ondol heating cost of the heat pump was less 20.6% than that of oil boiler when oil price was 478 won/l.

  • PDF

A Study on the Korean Ondol-System Application in Apartment Houses (공동주택의 한국형 온돌시스템 적용에 관한 연구)

  • Ahn, Min-Hee;Choi, Chang-Ho;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.860-865
    • /
    • 2006
  • The traditional Korean Ondol System that is a radiant floor heating system was made as warm floor and cool indoor temperature. Nowaday, Ondol is developed as the hydronic floor heating system. But unbalance of floor temperature and indoor temperature is occurred bocause strengthen thermal insulation and airtightness in building changes thermal performance. To solve these problems, we examine actual indoor environment of heating system methods in existing apartments and present the new method of floor heating system. The existing heating system made definite indoor temperatures but floor temperatures that is $22^{\circ}C-26^{\circ}C$ was maintained. To solve these problems, we adopted the differential heating system which made warm area and cool area. A differential heating system was made different pitches of heating pipe in single zone and ratio of warm area to cool area is 1 to 2. As a result of experiments, warm area temperature is $40.7^{\circ}C$, cool area temperature is $36.1^{\circ}C$. A difference of temperature between both area is 4K. A distribution of indoor vertical temperature is similar to both warm area and cool area.

  • PDF

Experimental Study on the Thermal Characteristics in Ondol Heating Systems (온돌난방주택의 난방방식별 열 특성에 관한 실험연구)

  • 윤정숙
    • Journal of the Korean housing association
    • /
    • v.1 no.1
    • /
    • pp.91-102
    • /
    • 1990
  • The aim of this study is to discover thermal characteristics of Ondol heating systems. The housing subjected was categorized into detached single family houses and apartments, reinforced concrete and brick structures, intermittent and continous heating system, and the space subjected was bedroom. In order to understand the thermal characteristics of each floor heating systems, the vertical distribution of indoor temperature and the distribution of surface temperature on the floor were measured. The vertical distribution of indoor temperature except the measurement point 1 largely showed average temperature distribution, and the temperature of the measurement point 1 in the housing surveyed showed the highest temperature in the house "sample A" because of the radiation heating from the floor of the Ondol room. As the result of the measurement, the thermal characteristics of each heating system were more stable distribution in apartments of R.C structure.structure.

  • PDF

An Experimental Study on the Thermal Efficiency of the Ondol House Beating System (온돌의 열효율에 관한 실험적 연구)

  • Bae soonhoon;Kang Shin-Hyoung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.3
    • /
    • pp.183-190
    • /
    • 1975
  • Most Korean houses are heated by the Ondol heating system. There has been, however, no reasonable design procedure availabe yet for the system. The conventional design should be improved to have auniform floor surface. temperature distribution and to have a high thermal efficiency. Thermal efficiencies of the ondol were defined and the method of experimentation was studied. An experiment, using a life-size model which was well insulated, was performed to observe the variation in thermal efficiency as the length of fuel burning time was varied.

  • PDF

A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구)

  • 임재한;여명석;양인호;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

A Study on the Application of the Radiant Floor Cooling System in Residential Building (주거 건물의 복사냉방시스템 적용에 관한 연구)

  • 임재한;여명석;김광우
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.73-82
    • /
    • 2004
  • The objective of this study is to demonstrate the potential of radiant cooling systems using Ondol as an alternative cooling system in residential buildings. For this purpose, computer simulation and model experiments have been performed for the system performance analysis regarding comfort, floor surface condensation, and supply water temperature. The results of this study is the following: In radiant floor cooling system, room air temperatures were maintained within the set temperature range of $\pm$1$^{\circ}C$ without any discomfort condition. And taking into account only the condensation occurrence, it was possible to achieve radiant floor cooling for a period of about 77% of the total cooling period in weather condition of Seoul. The minimum supply water temperature is about 15$^{\circ}C$, so renewable energy system such as ground heat exchange system can be used as an alternative in cooling source. Also, floor surface condensation can be prevented by integrating with the dehumidification system.

A Study on Bedclimate, Physiological Responces and Subjective Sensations of Bedquilts During Sleeping on Ondol in Summer (여름철 온돌에서 취침시 이불종류에 따른 침상기후와 인체반응 연구)

  • Kweon Soo Ae;Lee Soon Won;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.3 s.43
    • /
    • pp.285-298
    • /
    • 1992
  • In this study, bedclimate was investigated depending on various bedquilts used oin ondol in summer. The environmental room condition was maintained at 26: $1^{\circ}C,\;75{\pm}3\%$ R.H., while the ondol surface was kept at $25{\pm}1^{\circ}C$ without heating. The types of bedquilts were hemp, cotton, quilt made of polyester padding with polyester/cotton cover. Two healthy young women were subjected for seven hours' sleep with two replications for this study. The results are as follows. 1) The range of the temperature under the mattress ($25.2\~32.4^{\circ}C$) was lower than that of the temperature on the mattress ($28.8\~35.5^{\circ}C$), or that of the temperature inside the bedquilts ($30.3\~34.4^{\circ}C$). The humidity inside the bedquilts increased during sleeping, and the range of R.H. was $58\~80\%$. 2) The ranges of bedclimate which subjects feel comfortable were $30.5\~33.8^{\circ}C$ on the mattress, $31.0\~34.9^{\circ}C$, $61\~74\%$ R.H. inside the bedquilts. At this range, the mean skin temper-ature of the subjects was $34.3^{\circ}C\~35.2^{\circ}C$. 3) When there was no heating, the weight of the bedding increased during sleeping, and the weight increase was largest in the case of mattress. 4) There were correlations among the skin temperature of three points of the body (abdomen, thigh, foot) and the temperature and R.H. inside the bedquilt. 5) The effect of the type of bedquilts on the microclimate and physiolosical responses were significant. 6) Generally, when there was no heating, the body heat was transferred to the ondol floor, in summer, heat was transferred mostly through the mattress.

  • PDF