• 제목/요약/키워드: On-spot test

검색결과 489건 처리시간 0.034초

차체구조용 SCPI 강도부재의 점용접간격이 압궤특성에 미치는 영향 (Influence of Spot Weld Pitches on Collapse Characteristics of SCPI Vehicle Members)

  • 차천석;박제웅;양인영
    • Journal of Welding and Joining
    • /
    • 제20권6호
    • /
    • pp.78-78
    • /
    • 2002
  • Front-side members are structures with the greatest energy absorbing capability in a front-end collision of vehicles. This paper was performed to analyze initial collapse characteristics of spot welded hat and double hat-shaped section members, which are basic shape of side members, on the shift of flange weld pitches. The impact collapse tests were carried out by using home-made vertical air compression impact testing machine, and impact velocity of hat-shaped section members is 4.17m/sec and that of double hat-shaped section members is 6.54m/sec. In impact collapse tests, the collapsed length of hat-shaped section members was about 45mm and that of double hat-shaped section members was about 50mm. In consideration of these condition, axial static collapse tests(0.00017m/sec) of hat and double hat-shaped section members were carried out by using UTM which was limited displacement, about 50mm. As the experimental results, to obtain the best initial collapse characteristics, it is important that stiffness of vehicle members increases as section shapes change and the progressively folding mode induces by flange welding pitch.

차체구조용 SCP1 강도부재의 점용접간격이 압궤특성에 미치는 영향 (Influence of Spot Weld Pitches on Collapse Characteristics for SCP1 Vehicle Members)

  • 차천석;박제웅;양인영
    • Journal of Welding and Joining
    • /
    • 제20권6호
    • /
    • pp.802-808
    • /
    • 2002
  • Front-side members are structures with the greatest energy absorbing capability in a front-end collision of vehicles. This paper was performed to analyze initial collapse characteristics of spot welded hat and double hat-shaped section members, which are basic shape of side members, on the shift of flange weld pitches. The impact collapse tests were carried out by using home-made vertical air compression impact testing machine, and impact velocity of hat-shaped section members is 4.17m/sec and that of double hat-shaped section members is 6.54m/sec. In impact collapse tests, the collapsed length of hat-shaped section members was about 45mm and that of double hat-shaped section members was about 50mm. In consideration of these condition, axial static collapse tests(0.00017m/sec) of hat and double hat-shaped section members were carried out by using UTM which was limited displacement, about 50mm. As the experimental results, to obtain the best initial collapse characteristics, it is important that stiffness of vehicle members increases as section shapes change and the progressively folding mode induces by flange welding pitch.

화원에 따른 광전식 연기감지기 반응시간 분석 (Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires)

  • 지승욱
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.

First Report of Pyrenophora tritici-repentis in Wheat (Triticum aestivum L.) in Korea and in vitro Selection of an Effective Fungicide

  • Min-Hye Jeong;Eu Ddeum Choi;Seol-Hwa Jang;Sang-Min Kim;Sook-Young Park
    • 한국균학회지
    • /
    • 제51권4호
    • /
    • pp.277-286
    • /
    • 2023
  • Tan spot, caused by Pyrenophora tritici-repentis, is a major foliar disease in wheat worldwide. In April 2021, tan spot symptoms were observed in a commercial wheat field in Suncheon, Jeonnam Province, Korea, with over 5% of the wheat leaves exhibiting symptoms. These symptoms included oval-shaped tan necrosis surrounded by a bright halo. The three representative isolates exhibited irregular mycelial growth on V8-potato dextrose agar and produced pseudothecia. Based on the concatenated sequence datasets of four multi-genes, including the internal transcribed spacer, large subunit ribosomal RNA, glyceraldehyde-3-phosphate dehydrogenase, and RNA polymerase II second-largest subunit genes, phylogenetic analysis revealed that these three isolates clustered in the same clade as P. tritici-repentis. Results of pathogenicity test indicated that the initial symptoms appeared 5 days post-inoculation (dpi), with typical tan spot symptoms developing at 7 dpi. The pathogen was successfully re-isolated from the symptomatic tissues, thus fulfilling Koch's postulates. Furthermore, we selected three fungicides that effectively inhibited the mycelial growth of P. tritici-repentis by more than 90% in vitro. To the best of our knowledge, this is the first report of tan spot disease in wheat in Korea.

SPOT-5 HRG 스테레오 영상으로부터 지형정보 추출 (Extracting Topographic Information from SPOT-5 HRG Stereo Images)

  • 이진덕;이성순;정태식
    • 대한공간정보학회지
    • /
    • 제14권4호통권38호
    • /
    • pp.61-70
    • /
    • 2006
  • 본 논문에서는 SPOT 5호 HRG 스테레오 영상을 이용하여 수치표고모형을 생성하기 위한 사진측량학적 처리과정을 제시하고 수치표고모형 생성을 위한 HRG supermode 영상의 정확도 잠재성을 평가하고자 하였다. 센서모델링을 위하여 광속조정을 행한 후 에피폴라 영상재배열과 영상정합 과정 등을 통하여 수치표면모형을 생성하였다. HRG 영상으로부터 추출된 DEM 성과를 축척 1:5000의 수치지형도로부터 추출된 기준 DEM과 여러 시험구간 상에서 비교하였다. 전체구간 중 5m 미만의 DEM 오차를 나타내는 부분의 비율은 53.8%이었고, 5m를 초과하는 오차부분은 구름, 수역, 건물 등에 의한 영향을 받는 것으로 확인되어 이러한 지역을 제외하고 평가한 정확도는 약 2.5m의 RMSE를 나타내었다. 아울러 추출된 수치표면모형(DSM)을 사용하여 3차원 건물모델과 대상지역 전체의 3차원 가시화 모델을 작성하였다.

  • PDF

Interferon-${\gamma}$ Enzyme-Linked Immunospot Assay in Patients with Tuberculosis and Healthy Adults

  • Kim, Cheol-Hong;Kim, Jong-Yeop;Hwang, Yong Il;Lee, Chang Youl;Choi, Jeong-Hee;Park, Yong-Bum;Jang, Seung-Hun;Woo, Heungjeong;Kim, Dong-Gyu;Lee, Myung Goo;Hyun, In-Gyu;Jung, Ki-Suck;Kim, Hyun Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • 제76권1호
    • /
    • pp.23-29
    • /
    • 2014
  • Background: Interferon-${\gamma}$ assays based on tuberculosis (TB)-specific antigens have been utilized for diagnosing and ruling out latent TB and active TB, but their utility is still limited for TB incidence countries. The aim of this study is to understand the clinical utility of enzyme-linked immunospot (ELISpot) assays among patients with clinically suspected TB and healthy adults in clinical practices and community-based settings. Methods: The ELISpot assays (T SPOT.TB, Oxford Immunotec, UK) were prospectively performed in 202 patients. After excluding those with indeterminate results, 196 were included for analysis: 41 were TB patients, 93 were non-TB patients, and 62 were healthy adults. Results: The sensitivity and negative predictive values of the T SPOT.TB assays for the diagnosis of TB were 87.8% and 89.1%, respectively, among patients with suspected TB. The agreement between the tuberculin skin test (10-mm cutoff) and the T SPOT.TB assay was 66.1% (kappa=0.335) in all participants and 80.0% (kappa=0.412) in TB patients. Among those without TB (n=155), a past history of TB and fibrotic TB scar on chest X-rays were significant factors that yielded positive T SPOT.TB results. There was a significant difference in the magnitude of T SPOT.TB spot counts between TB patients and non-TB patients or healthy adults. Conclusion: The T SPOT.TB assay appeared to be a useful test for the diagnostic exclusion of TB. A positive result, however, should be cautiously interpreted for potential positives among those without active TB in intermediate TB incidence areas.

전기아연 도금 TRIP강판의 저항 점용접 시 연속타점 수명에 미치는 단상 AC와 인버터 DC의 비교 연구 (A Comparative Study of Single-Phase AC and Inverter DC on Electrode Life for Resistance Spot Welded Electrogalvanized Steel Sheets)

  • 손종우;박영도;강문진;김동철
    • 대한금속재료학회지
    • /
    • 제47권12호
    • /
    • pp.834-841
    • /
    • 2009
  • A study on the welding of electrogalvanized TRIP (Transformation-Induced Plasticity) steels was done to compare the life of the electrode and the alloying phenomena on the electrode tip surface using singlephase AC and inverter-DC resistance welding processes. A longer life of the electrode (>200 welds) was achieved using the inverter-DC welding process. The tensile shear strength was higher in the electrode life test when welded with the inverter DC welding machine it maintained a higher value even when the welding nugget diameter was smaller than specified. When spot-welding was conducted using the single-phase AC welding process, a higher wear rate of the electrode was observed compared to that with the inverter-DC process. An alloying layer used to determine the rate of electrode growth showed differences in the metallurgical features of the surface alloying and Zn penetration depending on whether the single-phase AC process or the inverter-DC welding process was used. Moreover, changes in the dynamic resistance during the electrode life test were correlated with the electrode wear (or growth) rate.

용접토우부의 그라인딩에 의한 피로강도 증대효과에 대한 연구 (A Study on the Fatigue Strength Improvement using Weld Toe Burr Grinding)

  • 강성원;김명현;최재영;김화수;백영민
    • Journal of Welding and Joining
    • /
    • 제24권2호
    • /
    • pp.42-47
    • /
    • 2006
  • While it is known that the weld toe grinding method may give 3.4 times of fatigue strength improvement, this improvement may significantly vary according to weld bead shapes and loading modes. Although tremendous interest have been given in improving fatigue strength improvement for ship structures, quantitative results are yet in need. In this context, a series of fatigue tests is carried out for a type of test specimen that are typically found in ship structures. Weld burr grinding is carried out using a electric grinder in order to remove surface defects and improve the weld bead profile. The test results are compared with the same type of test specimen without applying the fatigue improvement technique in order to obtain a quantitative measure of the fatigue strength improvement. On the other hand, both hot spot stress and structural stress methods are employed to compare the effectiveness of the two methods in evaluating the fatigue strength improvement of welded structures.

외부마감재가 부착된 볼트접합 방식 패널링 시스템의 내진성능평가를 위한 진동대 실험 (Shake Table Test on Seismic Performance Evaluation of the Bolted Connection Type Paneling System with Exterior Finish Material)

  • 오상훈;박종원;박해용
    • 한국지진공학회논문집
    • /
    • 제22권1호
    • /
    • pp.23-32
    • /
    • 2018
  • In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.

Xanthomonas fragariae에 의한 딸기 세균성모무늬병 (Angular Leaf Spot of Strawberry Caused by Xanthomonas fragariae)

  • 권진혁;윤혜숙;김정순;심창기;남명현
    • 식물병연구
    • /
    • 제16권1호
    • /
    • pp.97-100
    • /
    • 2010
  • 2009년 진주시 수곡면 딸기 노지재배 육묘 포장과 하동군 옥종면 촉성재배 시설하우스 딸기포장에서 병이 발생하였다. 병징은 잎에 수침상의 작은 반점이 서서히 생기면서 엽맥의 주위에 다각형의 모무늬 병반이 나타나고 노란색의 달무리가 형성하는 것이 특징이다. 병든 잎은 서서히 시들고 암갈색으로 말라 죽는다. YDC 배지 상에서 병원균의 균총은 노란색을 띤 오랜지 색소를 분비하며 둥근 콜로니를 형성하고 단극모를 가지고 있다. 딸기에 접종한 결과 병원성이 잘 나타났다. 이상과 같이 딸기에 발생한 병정, 병원균의 특징 및 병원성을 검정한 결과 Xanthomonas fragariae에 의한 딸기 세균성모무늬병으로 동정하였다.