• Title/Summary/Keyword: On-pump

Search Result 3,843, Processing Time 0.036 seconds

Thrust Estimation Acting on Rotor of LOX Pump for Liquid Rocket Engine (액체로켓엔진용 산화제펌프 회전체의 하중 예측)

  • Kim, Dae-Jin;Choi, Chang-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.6
    • /
    • pp.98-104
    • /
    • 2015
  • Excessive thrust acting on the rotor of pump can cause the damage of pump or the decrease of pump lifetime. Therefore, for ensuring the safety of LOX pump of a liquid rocket engine, the thrust of pump rotor is estimated by similarity tests. Axial thrust is indirectly measured by an axial thrust measurement unit positioned outside pump. Radial thrust is calculated based on pressure distribution of volute scroll. As a result, axial and radial thrust are increased when the flowrate of pump decreases. However, both thrusts do not affect the stability of pump rotor since their values are not large.

Electrophysiological study on the presence of the electrogenic Na pump of the mouse unfertilized eggs (Mouse 미수정란에서의 electrogenic Na pump 활동여부에 관한 연구)

  • Hong, Seong-geun
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.3
    • /
    • pp.245-251
    • /
    • 1989
  • In order to manifest the presence of Na-K pump and its property on the unfertilized egg membranes of mouse, membrane potential was recorded under the physiological condition (at $37^{\circ}C$ and 4mM $Ca^{2+}$). After an induction of superovulation, the fresh eggs with zona pellucida were collected from mouse oviduct. Transient hyperpolarization as pump action was recorded after the switch into the high potassium perfusate (15mM $K^+$) from K-free perfusate, and the difference between membrane potential observed just before the perfusion of high potassium solution and the maximal membrane potenlial during the perfusion of high potassium solution was regard as pump activities. The results observed were as follows, 1. Resting mombrane potential was depolarized under the treatment of $10^{-5}M$ ouabain. 2. Pump activities of the unfertilized mouse eggs were $-3.38{\pm}0.61mV$ ($Mean{\pm}SD$, n=6), recorded as transient hyperpolarization due to the electrogenic property. 3. Pump activities were blocked by both treatment of $10^{-5}M$ ouabain and perfusion of Nafree solution, while increased by high $Na^+$ (300mM) perfusion ($-7.45{\pm}0.75mV$, n =2). 4. Hyperpolarization due to pump activity was not altered by $Mn^{2+}$. 5. Above results confirm the presence of ouabain-sensitive Na-K pump, which affected the membrane potential directly, on the unfertilized egg membranes of mouse.

  • PDF

Influence of Circualr Casing on the Performance of Very Low Specific Speed Centrifugal Pump (원형케이싱이 극저비속도 원심펌프의 성능에 미치는 영향)

  • Choi, Young-Do;Kagawa, Shusaku;Kurokawa, Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.1 s.34
    • /
    • pp.32-39
    • /
    • 2006
  • Recently, according to the trend of small size in scale and high speed in rotation of turbomachinery, very low specific speed centrifugal pump is taking a growing interest because the pump is characterized by high head and low flow rate with convenience of manufacturing and maintenance compared with conventional positive displacement pump. However, the efficiency of the very low specific speed centrifugal pump drops rapidly with the decrease of specific speed. The purpose of this study is nor only to examine the influence of casing type on the performance of centrifugal pump in the range of very low specific speed but also to determine the proper casing type for the improvement of pump performance. The results show that circular casing is suitable for the centrifugal pump in the range of very low specific speed and the influence of impeller configuration on the pump performance is very small. Radial thrust in the circular and volute casings is considerably small in the range of very low specific speed.

Air Influx Characteristics of Turbo Pumps (공기 유입시의 터보펌프 특성)

  • Kim, You-Taek;Nam, Cheong-Do;Kang, Ho-Keun;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.43-48
    • /
    • 2004
  • A screw-type centrifugal pump was manufactured to carry solids primarily and its impeller has a wide flow passage. However, the effect of flow passage shape on delay of the choke due to entrained air has not been clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For that reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that loss of pump head from single-phase flow to the choke due to air entrainment new the best efficiency point was large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF

An Investigation of the Pump Operating Characteristics as a Novel Control Index for LVAD Control

  • Choi Seongjin;Boston J. Robert;Antaki James F.
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.100-108
    • /
    • 2005
  • This work presents a novel control index to regulate the pump speed of an axial flow blood pump for the left ventricular assist device (LVAD). The control index is based on the characterization of pump operating conditions such as normal or suction status. The pump operating characteristics reveal that a certain pulsatility relationship between the pump pressure difference and the pump flow is a unique index to identify the pump operating status under the diverse pump operating environments.

Effect of Drag Stages Surface Roughness on the Compression Ratio of a TMDP

  • Bianco, Alessandra Dal;Bonmassar, Luca
    • Applied Science and Convergence Technology
    • /
    • v.25 no.6
    • /
    • pp.120-123
    • /
    • 2016
  • The rotor of a turbomolecular drag pump is generally made of an aluminum alloy. Its surface finish is affected by various processes that the rotor itself undergoes during the manufacturing phase. The impact of different surface finishes on the pumping performances of a turbomolecular pump has been mainly investigated by Sawada et al [1]. The present work aims to broaden the previous bibliographic study to the drag stages of a turbomolecular pump by testing the impact of different surface finishes on the compression ratio of the pump. Experimental tests have been made focusing on two processes: the corundum sandblasting and the glass microspheres shot-peening. Both the processes flatten and/or physically remove EDM melted spheres; in particular, blasted surfaces obtained by glass shot-peening are generally smoother than surfaces obtained by corundum sandblasting. In order to characterize the surface texture left by such processes, preliminary surface roughness measurements have been made on the drag rotor disks of several pumps. The experimental tests conducted on both sandblasted and shot-peened rotors confirms previous results obtained on the turbo stages by Sawada et al. [1], showing that the average roughness of the surface has an impact on the compression ratio of the pump; in particular, an increment in the surface roughness causes a corresponding increment in the compression ratio of the pump and vice versa. For the tested pumps, the higher surface roughness gives a factor of increment of about 2 on the measured hydrogen maximum compression ratio of the pump.

The effect of suction pipe leaning angle on the internal flow of pump sump

  • Lee, Youngbum;Kim, Kyung-Yup;Chen, Zhenmu;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.8
    • /
    • pp.849-855
    • /
    • 2015
  • A better flow condition for the intake of pump is provided by the sump pump that connects the forebay to the intake of the pump station. If the suction sump is improperly shaped or sized, air-entraining vortices or submerged vortices may develop. These phenomena may greatly affect pump operation if vortices become sufficiently large. Moreover, any remaining vortices in the pump flow passage may result in an increase in the noise and vibration of the pump. Therefore, the vortices in the pump flow passage must be reduced to achieve good pump sump station performance. In this study, the effect of suction pipe leaning angle on the pump sump's internal flow is investigated. Additionally, a pipe type with an elbow shape is investigated. The results show that the air entraining vortices occur under the condition of a water level ratio H/D = 1.31 for each suction pipe type.

Cavitation in a Shaft-less Double Suction Centrifugal Miniature Pump

  • Zhuang, Baotang;Luo, Xianwu;Zhu, Lei;Wang, Xin;Xu, Hongyuan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.191-198
    • /
    • 2011
  • Based on the consideration that the cavitation would affect the operation stability of miniature pumps, the 3-D turbulent cavitating flow in a test pump was simulated by using a mixed cavitation model and k-${\omega}$ SST turbulence model. In order to investigate the influence of inlet geometry parameters on the cavitation performance of the miniature pump, two more impellers are designed for comparison. Based on the results, the following conclusions are drawn: 1) Cavitation performance of the double suction shaft-less miniature pump having different impeller is equivalent to the centrifugal pump having ordinary size, though the flow passage at impeller inlet is small; 2) The miniature pump having radial impeller can produce much higher pump head, but lower cavitation performance than that having the impeller based on the conventional design method; 3) It is believed that by applying the double suction design, the miniature pump achieved relatively uniform flow pattern upstream the impeller inlet, which is favorable for improving cavitation performance.

Effect of Discharge Electrode Shape of a Barrier Discharge Type Gas Pump on Ionic Wind Generation (장벽 방전형 공기 펌프의 이온풍 발생에 미치는 방전전극 형상의 영향)

  • Hwang, Deok-Hyun;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.994-998
    • /
    • 2009
  • Existing cooling technologies no longer provide adequate heat dissipation due to excessive heat generation caused by the growing component density on electronic devices. An ionic gas pump can be used for the thermal management of micro-electronic devices, since the size of pump can be reduced to a micrometer scale. In addition, the gas pump allows for gas flow control and generation without moving parts. This ideal property of gas pump gives rise to a variety of applications. However, all these applications require maximizing the wind velocity of gas pump. In this study a barrier discharge type gas pump, with a needle-shaped corona electrode instead of a plate-shaped corona electrode, has been investigated by focusing on the corona electrode shape on the wind velocity and wind generation yield. As a result, the enhanced wind velocity and wind generation yield of 1.76 and 3.37 times were obtained with the needle-shaped corona electrode as compared with the plate-shaped corona electrode of the proposed barrier discharge type gas pump.

Air-Water Two-phase Flow Patterns and Pressure Distributions in a Screw-type Centrifugal Pump

  • Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1203-1210
    • /
    • 2004
  • It was reported recently that the pump head degradation near the best efficiency point from single-phase flow to the break-down due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. In this paper, I carried out internal pressure measurements and visualizations, and investigated the various physical phenomena occurring inside a screw-type centrifugal pump operated in air-water two-phase flow. The results could give some characteristics about the degradation of pump performance on air-water two-phase flow.