• 제목/요약/키워드: On-line monitoring system

검색결과 761건 처리시간 0.024초

열연강판의 드릴가공시 공구의 마멸량 검출에 관한 연구 (A Study on the Detection of Tool Wear in Drilling of Hot-rolled High Strength Steel)

  • 신형곤;김태영
    • 한국정밀공학회지
    • /
    • 제18권11호
    • /
    • pp.148-154
    • /
    • 2001
  • Drilling is one of the most important operations in machining industry and usually the most efficient and economical method of cutting a hole in metal. From automobile parts to aircraft components, almost every manufactured product requires that holes are to be drilled for the purpose of assembly, creation of fluid passages, and so on. It is therefore desirable to monitor drill wear and hole quality changes during the hole drilling process. One important aspect in controlling the drilling process is monitoring drill wear status. A drill-wear monitoring system provides information about drill status. With the information, optimum planning for tool change is possible. And drill-wear monitoring system in needed to evaluated drilled hole quality and the wear of drill. Accordingly, this paper deals with an on-line drill wear monitoring system of the detection of tool wear with the computer vision and the area of the drill flank wear is analyzed quantitatively by the system.

  • PDF

고압 전동기 고정자 권선의 절연진단을 위한 운전중 부분방전 측정 시스템 개발 (Development of On-Line Partial Discharge Measuring System for Insulation Diagnosis of High-Voltage Motor Stator Windings)

  • 황돈하;강동식;신병철;이영진;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.481-486
    • /
    • 2006
  • In this paper, a new on-line high-voltage motor monitoring system is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). And this system displays magnitude and phase angle distribution of PD. Sensor, CC (Ceramic Coupler) is used for PD measurement. PD signals are continuously measured and digitized with a A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-232, 422, and TCP/IP. This helps more efficient operation and maintenance of the high-voltage motor.

  • PDF

Real-time Monitoring of Ethernet Passive Optical Network Using Burst-mode FBGs

  • Binh, Nguyen Khac;Choi, Su-il
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.186-192
    • /
    • 2020
  • This paper describes a real-time monitoring system in Ethernet passive optical networks (EPON) that uses burst-mode fiber Bragg grating (FBG) optical sensors. The FBG interrogation unit in the optical line terminal (OLT) transmits the monitoring wavelength to optical network units (ONUs). The FBG sensor unit in each ONU returns a burst-mode monitoring signal to the OLT. As the system applies time division multiple access (TDMA), a uniform Bragg wavelength can be used to monitor the EPON system. The FBG interrogation unit analyzes the received burst-mode monitoring signals and outputs fault information on the ONU branches in EPON. The simulation results show the effectiveness of the proposed monitoring system based on TDMA. In addition, we compared the proposed TDMA-based monitoring system with a WDMA-based monitoring system.

On-line Temperature Monitoring of the GIS Contacts Based on Infrared Sensing Technology

  • Li, Qingmin;Cong, Haoxi;Xing, Jinyuan;Qi, Bo;Li, Chengrong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1385-1393
    • /
    • 2014
  • Gas insulated switchgear (GIS) is widely used in the power systems, however, the contacts overheating of the inside circuit breaker or disconnector may be a potential cause of developing accidents. As the temperature of the contacts cannot be directly acquired due to existence of the metallic shield, an infrared sensor is adopted to directly measure the temperature of the shield and then the contacts temperature can be indirectly obtained by data fitting, based on which the on-line temperature monitoring technology specifically for GIS contacts based on infrared sensing is proposed in this paper. A real GIS test platform is constructed and experimental studies are carried out to account for the influential factors that affect the accuracy of the infrared temperature measurement. A heat transfer model of the GIS module is also developed, together with experimental studies, the nonlinear temperature relationship among the contacts, the metallic shield and the environment based on a neural network algorithm is established. Finally, an integrated on-line temperature monitoring system for the GIS contacts is developed for on-site applications.

ON-line System을 이용한 오존 Precursor의 거동에 대한 연구 (Studies on the Variation of the Ozone Precursors using On-Line Air Monitoring System)

  • 조석주;윤중섭;여인학;이민환;김민영;김신도
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 춘계학술대회 논문집
    • /
    • pp.251-252
    • /
    • 2002
  • 최근 서울시보건환경연구원에서는 국내 최초로 미국의 PAMS(Photochemical Assessment Monitoring Systems) 측정망을 응용한 VOCs 측정망을 구축하여 대기 중 탄화수소를 포함하는 휘발성유기화합물를 측정 운영 중에 있다. VOCs는 그 종류와 발생원이 복잡 다양할 뿐만 아니라 시료의 채집과 분석방법에 여러 가지 기술적인 어려움이 내재한다. (중략)

  • PDF

티타늄 합금의 슬롯가공에서 엔드밀 공구마멸 감시 (Tool wear monitoring of end mill in slot machining of titanium alloy)

  • 하건호;구세진;김정석;양순철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 1995
  • A acoustic emission (AE) sensor has been used to monitor tool were during milling process. The relation between tool wear and AE RMS (Root mean Square) signal was investigated experimentally. A avaliable monitoring index for monitoring toolwear was newly extracted form AE RMS. And on-line monitoring program was developed. The proposed monitoring system has verified experimentally by roughing end milling titanium alloy with TIN coated HSS tool.

  • PDF

사우디아라비아 380kV XLPE Cable의 신뢰성 확보를 위한 온라인 부분방전 모니터링 시스템 구축 (Construction of On-line Partial Discharge Monitoring System for 380kV XLPE Cable in Saudi Arabia)

  • 서인진;이전선;김한중;김종철;김정윤;이현선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.95-96
    • /
    • 2008
  • We constructed an on-line PD monitoring system for the 380kV U/G Cable project at the Riyad 9012 substation in Saudi-arabia. The system will be monitoring the termination of the two 380kV XLPE Cables to prevent unexpected failure of the cable insulation. The system had been tested in the laboratory and on-site for detection of various PD signals and reliability of operation. The system distinguish the existence and nonexistence of the partial discharge and then judge the source of partial discharge using automatic PD pattern recognition software.

  • PDF

Development of On-line Performance Diagnostic Program of a Helicopter Turboshaft Engine

  • Kong, Chang-Duk;Koo, Young-Ju;Kho, Seong-Hee;Ryu, Hye-Ok
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제10권2호
    • /
    • pp.34-42
    • /
    • 2009
  • Gas turbine performance diagnostics is a method for detecting, isolating and quantifying faults in gas turbine gas path components. On-line precise fault diagnosis can promote greatly reliability and availability of gas turbine in real time operation. This work proposes a GUI-type on-line diagnostic program using SIMULINK and Fuzzy-Neuro algorithms for a helicopter turboshaft engine. During development of the diagnostic program, a look-up table type base performance module are used for reducing computer calculating time and a signal generation module for simulating real time performance data. This program is composed of the on-line condition monitoring program to monitor on-line measuring performance condition, the fuzzy inference system to isolate the faults from measuring data and the neural network to quantify the isolated faults. Evaluation of the proposed on-line diagnostic program is performed through application to the helicopter engine health monitoring.

베이지언 기법을 이용한 수계 내의 독성물질 판단 (On-line identification of the toxicological substance in the water system using Baysian technique)

  • 정하규;정종혁;이현욱;권원태;김상길;전숙례
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3122-3127
    • /
    • 2007
  • Water resource can be examined using biological sensors. Algae has been one of the biological sensors used to evaluate and monitor the water pollution. The monitoring system, however, could determine whether the examined water was safe or not. It needs additional expensive chemical test to figure out the cause of the water pollution. In this study, an endeavor is given to identify the toxicant in the water using the shape of the chlorophyll fluorescence induction curve(FIC) from algae using monitoring system. Fundamental curves are obtained from the experiments with specified amount of toxicant. Baysian method is utilized to determine the unknown toxicant in the water by comparing it with the fundamental curves. The results shows that the proposed method works fairly well.

  • PDF

베이지언 기법을 이용한 수계 내의 독성물질 판단 (On-line identification of the toxicological substance in the water system using Baysian technique)

  • 정하규;정종혁;이현욱;권원태;김상길;전숙례
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.73-78
    • /
    • 2008
  • Water resource can be examined using biological sensors. Algae has been one of the biological sensors used to evaluate and to monitor the water pollution. The monitoring system, however, has not been used to determine what kind of the toxicological substance is in the water. It needs additional expensive chemical test to figure out the cause of the water pollution. In this study, an endeavor is made to identify the toxicant in the water using the shape of the chlorophyll fluorescence induction curve(FIC) from algae using monitoring system. Fundamental curves are obtained from the experiments with specified amount of toxicant. Baysian method is utilized to determine the unknown toxicant in the water by comparing it with the fundamental curves. The results shows that the proposed method works fairly well.