• Title/Summary/Keyword: On-line estimation

Search Result 980, Processing Time 0.065 seconds

A Study on the Stress Analysis and Parameters of Bucking in Spherical Shell (반 구형 각의 좌굴현상에 대한 응력해석 및 영향인자에 관한 연구)

  • Kim, Yeong-Su;An, Du-Seong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.2
    • /
    • pp.142-150
    • /
    • 1985
  • In this paper, stress distribution were given in consideration of bending effects in hemi-spherical shell and a modified equation of buckling load was represented with implicating the effects of plastic deformations and shape parameters. Especially, the distributions of shell near it's vertex were analyzed numerically, according to several cases of loading. For the sake of more good estimation of plastic dissipating energy, we used the yield-line method from plate theory. The modified criterion of bucking, P super(*) sub(cr), that was suggested in this study, was applied to SUS 302 stain-less steel hemi-spherical shell which had it's Poisson's ratio and Young's modulus with 0.33 and 19700 kg/mm$^2$. From some experiments and comparisons with other results, 재 suggested the critical buckling-load-equation with P super(*) sub(cr)=2E super(*).(t super(2)/a super(2)).{3(1-ν super(*2)} and computed the buckling initiation load with this equation. Because these result from modified criterion have more coincidence than previous one, we prospect this equation can be magnified it's utilities to the other materials.

  • PDF

Development and transcription estimation of an automotive interior plastic part(HD Switch Panel) with no glossy etching pattern (무광부식 패턴을 갖는 자동차 내장부품인 HD Switch Panel의 제조 및 전사성 평가)

  • Kim, Young-Kyun;Kim, Dong-Hak;Son, Young-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3280-3286
    • /
    • 2009
  • In this paper, we designed and manufactured HD Switch Panel parts with micro-etched pattern. By using CAE analysis, we could predict weld-line positions and the amount of shrinkage during injection molding process. We measured the temperature distribution of the mold surface so that we could optimize the processing conditions such as mold temperature. In order to increase the transcription of micro-etched pattern, we applied the E-Mold technology and evaluated the effect of mold temperature on the surface quality. We concluded that the etched pattern was improved(more than 2.5$\to$1.5~1.7) through the measurement of surface gloss and the observation of both SEM and SPM images.

Generalized Formula for Active Earth Pressure Estimation with Inclined Retaining Wall (점착력을 고려한 배면 경사 옹벽에서의 주동토압 산정 공식)

  • Kim, Woncheul;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.5
    • /
    • pp.71-81
    • /
    • 2008
  • Active earth pressure formula, which can consider the effects of ground surface inclination, inclination of inside retaining wall face, wall friction, line load, uniform load, soil cohesion and adhesion, was derived based on the force equilibrium principle. In order to verify the accuracy of this proposed formula, the calculated active earth pressures by the proposed formula were compared with those of graphical solutions. Also, the active earth pressures determined by the proposed formula were compared with those by Coulomb's, Rankine's and Mazindrani's solution under specific conditions. The results matched quite well not only with the graphical solutions but also with those by three other methods. Also, the trend of active earth pressures by the proposed formula were corresponded with results of experimental study by Fang, et al. It can be concluded that this generalized formula not only can overcome the limitations of Rankine's, Coulomb's and Mazindrani's active earth pressure formula but also can consider the external loading conditions.

  • PDF

Estimation of the zone of excavation disturbance around tunnels, using resistivity and acoustic tomography

  • Suzuki Koichi;Nakata Eiji;Minami Masayuki;Hibino Etsuhisa;Tani Tomonori;Sakakibara Jyunichi;Yamada Naouki
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.62-69
    • /
    • 2004
  • The objective of this study is to estimate the distribution of a zone disturbed by excavation (EDZ) around tunnels that have been excavated at about 500 m depth in pre-Tertiary hard sedimentary rock. One of the most important tasks is to evaluate changes in the dynamic stability and permeability of the rock around the tunnels, by investigating the properties of the rock after the excavation. We performed resistivity and acoustic tomography using two boreholes, 5 m in length, drilled horizontally from the wall of a tunnel in pre-Tertiary hard conglomerate. By these methods, we detected a low-resistivity and low-velocity zone 1 m in thickness around the wall of the tunnel. The resulting profiles were verified by permeability and evaporation tests performed at the same boreholes. This anomalous zone matched a high-permeability zone caused by open fractures. Next, we performed resistivity monitoring along annular survey lines in a tunnel excavated in pre-Tertiary hard shale by a tunnel-boring machine (TBM). We detected anomalous zones in 2D resistivity profiles surrounding the tunnel. A low-resistivity zone 1 m in thickness was detected around the tunnel when one year had passed after the excavation. However, two years later, the resistivity around the tunnel had increased in a portion, about 30 cm in thickness, of this zone. To investigate this change, we studied the relationship between groundwater flow from the surroundings and evaporation from the wall around the tunnel. These features were verified by the relationship between the resistivity and porosity of rocks obtained by laboratory tests on core samples. Furthermore, the profiles matched well with highly permeable zones detected by permeability and evaporation tests at a horizontal borehole drilled near the survey line. We conclude that the anomalous zones in these profiles indicate the EDZ around the tunnel.

Estimation of Carbonation and Service Life of Box Culvert for Power Transmission Line (박스형 전력구의 콘크리트 탄산화에 의한 잔존수명 예측)

  • Woo, Sang Kyun;Lee, Yun;Yi, Seong Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.116-121
    • /
    • 2012
  • The construction of underground structures such as box culverts for electric power transmission is increasing more and more, and the life extension of these structures is very important. Carbonation-induced corrosion in concrete may often occur in a high carbon dioxide environment. In this study, the risk of carbonation of two concrete box culverts in an urban area was evaluated by measuring the carbonation rate and concrete cover depth. Then, the carbonation-free service life at the depth of the steel was calculated, based on in situ information, by the Monte Carlo simulation. The service life of box culvert due to carbonation was estimated over 250 years via Monte Carlo simulation.

The Sensitivity Analysis and Safety Evaluations of Cable Stayed Bridges Based on Probabilistic Finite Element Method (확률유한요소해석에 의한 사장교의 민감도 분석 및 안전성 평가)

  • Han, Sung-Ho;Cho, Tae-Jun;Bang, Myung-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.141-152
    • /
    • 2007
  • Considering uncertainties of random input data, it is more reasonable to use probabilistic method than the conventional deterministic method for the design of structures or for the assessment of the responses of structures, which are designed as safe even under extreme loads. Therefore, to assess the quantitative effects of the constructed cable stayed bridge by the input random variables, a sensitivity analysis is studied. Using perturbation method, an analysis program is developed for the iterative probabilistic finite element analyses and sensitivity analyses of the cable stayed bridge, except the initial shape analysis. Monte-Carlo Simulations were used for the verification of the developed program. The results of sensitivity analysis shows the governing effects of external loads. Because the results also provide the sensitive effects of the stiffness of members and the magnitudes of prestressing force of cables, the developed

Study on Characteristics of Visual-Perception by Presence of Object in Exhibition Hall (전시공간 홀에서 대상체의 유무에 따른 시지각 특성 연구)

  • Choi, Gae-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.6
    • /
    • pp.106-115
    • /
    • 2017
  • This study has analysed the characteristics of observation by presence of objects in exhibition spaces through eye-tracking. The area with prevailing observation by the change of observation time with visual-perception response to the presence of objects has been analyzed to figure out the mechanism of sensibility estimation which can take place while the visual-perception is being estimated in spaces. Research results are able to ascertain that First, it was very characteristic that the signs right and left were observed more when there were no objects while when there were objects they were observed prevailingly. Second, the characteristics by section when there were any objects showed that there were more high observation scale I (more than 1000ms). When there were any objects with the number of areas where all the participants prevailed commonly, the scale was more, also. Third, in the process of acquiring any visual-perception information in spaces, the element of landmark can be regarded as a control point for space cognition, where the objects (people) became landmark when there were the objects but the signs became landmark when there were no objects. Fourth, the polynomial trend line of the changes to prevailing observation frequency by observation time shows that there was a gradual average value in general when there were any objects and then after the time range[8] the prevailing observation frequency increased. Without any objects, after a particular time range the value sharply dropped along with the increase of observation time because no objects to be observed prevailingly couln't be seen. The gradual average value means that some elements in the space were prevailingly observed all the time.

Application of Geophysical Exploration Technique to the Identification of Active Weak Zones in Large Scale Mountainous Region (대규모 산지지반 활동연약대 규명을 위한 지구물리탐사기법의 활용 연구)

  • Shin, Hyung Ohk;Kim, Man-Il;Yoon, Wang Joong
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.3
    • /
    • pp.162-170
    • /
    • 2018
  • The purpose of this study is to understand the ground change of large scale mountainous region and to estimate the active weak zone using geophysical exploration (electrical resistivity and refraction seismic explorations) in large scale deep landslide area located in Wanjugun, Jeollabukdo. We also analyzed the characteristics of deep landslides occurred in metamorphic rocks region and confirmed the approximate scale. As a result of comparative analysis of N-value by standard penetration test (SPT), low resistivity anomaly, and tension crack identified from field investigation, a discontinuity in soil layer was estimated at 10 ~ 15 m below the surface. Based on this results, the distribution pattern of active weak zone was confirmed between the discontinuity in soil layer and estimation line of bedrock.

Analysis of the temporal stratification variation pattern in Mikawa Bay, Japan (일본 미카와만의 시간적인 성층변화 양상 분석)

  • Cho, Hong-Yeon;Cho, Bong-Sik
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.3
    • /
    • pp.171-180
    • /
    • 2010
  • Analysis on the temporal variation of the stratification is carried out by using the continuous water temperature and salinity data observed in the coastal monitoring buoy in Mikawa Bay, Japan. The main analysis results are as follows. The stratification pattern have an obvious and dominant 1-year period variation and the occurrence frequency (days) are exponentially decreased as the stratification intensity (SI) defined as the density difference between surface and bottom layers linearly increases. The frequency distribution function of the SI is presumably close to the log-normal function type or exponential function type. From the water temperature and salinity scatter diagram analysis, the line and loop type patterns are shown in the bottom and surface layers, respectively. In addition, the analysis of the SI estimation show that the error bound in case of using the weekly-monitoring data is about 4.45 times greater than that in case of using the continuous (daily) monitoring data.

Anticorrosive Monitoring and Complex Diagnostics of Corrosion-Technical Condition of Main Oil Pipelines in Russia

  • Kosterina, M.;Artemeva, S.;Komarov, M.;Vjunitsky, I.;Pritula, V.
    • Corrosion Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.208-211
    • /
    • 2008
  • Safety operation of main pipelines is primarily provided by anticorrosive monitoring. Anticorrosive monitoring of oil pipeline transportation objects is based on results of complex corrosion inspections, analysis of basic data including design data, definition of a corrosion residual rate and diagnostic of general equipment's technical condition. All the abovementioned arrangements are regulated by normative documents. For diagnostics of corrosion-technical condition of oil pipeline transportation objects one presently uses different methods such as in-line inspection using devices with ultrasonic, magnetic or another detector, acoustic-emission diagnostics, electrometric survey, general external corrosion diagnostics and cameral processing of obtained data. Results of a complex of diagnostics give a possibility: $\cdot$ to arrange a pipeline's sectors according to a degree of corrosion danger; $\cdot$ to check up true condition of pipeline's metal; $\cdot$ to estimate technical condition and working ability of a system of anticorrosive protection. However such a control of corrosion technical condition of a main pipeline creates the appearance of estimation of a true degree of protection of an object if values of protective potential with resistive component are taken into consideration only. So in addition to corrosive technical diagnostics one must define a true residual corrosion rate taking into account protective action of electrochemical protection and true protection of a pipeline one must at times. Realized anticorrosive monitoring enables to take a reasonable decision about further operation of objects according to objects' residual life, variation of operation parameters, repair and dismantlement of objects.