• Title/Summary/Keyword: On-line절연진단

Search Result 39, Processing Time 0.022 seconds

Study on Development of Insulation Degradation Diagnosis System for Electrical Transformer (변압기 절연열화진단 시스템개발에 관한 고찰)

  • 김이곤;유권종;김서영;조용섭;박봉서;최시영;심상욱
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.139-144
    • /
    • 2001
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defect. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear, it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a magnetic wave and acoustic signal to diagnoses an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System) and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, design of the neuro-fuzzy model that diagnoses an electrical equipment is investigated. Validity of the new method is asserted by numerical simulation.

  • PDF

Development of an On-Line Insulation Diagnosis System when operating a High-Voltage Motor Using a Ceramic Coupler (세라믹 커플러를 이용한 고압 전동기 운전 중 절연 진단 시스템 개발)

  • Se, Il-Soo;Shin, Byoung-Chol;Lee, Sang-Min;Oh, Bong-Keun;Kim, Hyeon-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1440-1442
    • /
    • 2007
  • A high-voltage motor has had many problems due to its frequent startup, standstills and occasions of long period operation. As for a solution to the problem, many advanced countries have developed an on-line insulation diagnosis sensor and a same type of system and put them in use. Recently, even in the domestic market, a ceramic coupler has been developed and attempted to be applied in the field. This paper proposes an on-line insulation diagnosis system when operating a high-voltage motor along with the use of a domestic ceramic coupler. The proposed system is composed with a ceramic sensor, a PDMS-HM, and a Remote Monitoring System. As the result of comparing this system with a PDAS, which is an expensive full A/D method, the reliability of the system has been verified, and furthermore, it is in the process of being commercialized.

  • PDF

Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.

Noise Elimination Algorithm for Detecting Partial Discharge of Generator Stator Winding Considering Relation of Periphery Signals (고압 회전기 고정자 권선의 부분방전 계측 시 주변 신호 관계를 고려한 노이즈 제거기법)

  • Shin, Hee-Sang;Cho, Sung-Min;Kang, Chul;Kang, Dong-Sik;Cho, Kuk-Hee;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.17-24
    • /
    • 2008
  • Recently, the importance of supplying the reliable electric power is increasing. therefore, the importance of diagnosis of power equipments is increasing also. Breaking insulation of stator windings is major cause of faults in high voltage generators. On-line PD (Partial Discharge) detection using Capacitive Coupler at stator windings is used widely to diagnose high voltage generator. However, precise PD(Partial Discharge) detection is impossible if detected signals are mixed with PD and noise signal. In this paper, we analyze detected signals using Capacitive Coupler at 13[kV] hydroelectric generator stator winding and suggest not hardware method but noise elimination algorithm for detecting PD of generator stator winding considering relation of periphery signals.

Study on Development of Insulation Degradation Diagnosis System for Electrical System (전기기기 절연열화진단 시스템개발에 관한 고찰)

  • Kim, Yi-Gon;Yoo, Kwen-Jong;Kim, Seo-Young;Cho, Yong-Sub;Bak, Bong-Seo;Choi, Si-Young;Sim, Sang-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.231-235
    • /
    • 2001
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defect. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear, it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a magnetic wave and acoustic signal to diagnoses an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System) and acquires 2D Patterns from analyzing it. For fettering the noise contained in sensor signals we used ICA algorithms. Using this data design of the neuro-fuzzy model that diagnoses an electrical equipment is investigated. Validity of the new method is asserted by numerical simulation.

  • PDF

UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear (가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법)

  • Song Won-Pyo;Kim Jung-Bae;Kim Min-So;Jung Jae-Ryong;Park Seung-Jae;Ko Heui-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

Detecting Characteristics of Ultrasonics Generated by Partial Discharge in Insulating Oil Using the Optical Fiber Mach-Zehnder Interferometer (광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성)

  • 이상훈;심승환;이광식;김달우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.50-56
    • /
    • 2003
  • It is well known that a partial-discharge(PD) in insulation oil is the source of various physical and chemical phenomena, such as heat, light, gas, chemical transformation, electric current, electromagnetic radiation and ultrasonics. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Ultrasonic-wave detection is a useful method for the diagnosis of the transformer-insulation condition. Conventionally, ulyrasonic waves are detected by Piezo-electric transducer, but we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

The Design of a Sensor for Measuring Partial Discharge Signals in Rotating Machines (부분방전 검출을 위한 저, 고주파용 센서 해석 및 설계)

  • Heo Chang-Geun;Kim Yong-Joo;Kang Dong-Sik;Jung Hyun-Kyo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.6-10
    • /
    • 2004
  • 회전기기의 운전 상태에서 on-line 부분 방전시험은 고정자 권선의 절연상태를 검사, 평가 할 수 있는 중요한 수단으로서 이러한 부분방전시험을 통하여 회전기기 시스템의 사고예방을 위한 진단을 할 수 있다. 기존의 비접촉식 센서인 SSC는 부분방전 측정을 위하여 권선의 웨지 아래에 설치하는 방식으로 개발되어 [1], 설치가 불편하고 Global VPI 방식으로 제작된 소형 회전기에는 설치할 수 없는 단점이 있다. 본 논문에서는 소형 회전기에 사용가능한 저, 고주파용 부분방전 센서를 제안하였다. 웨지 위에 설치 가능한 SSC 형태의 마이크로스트립 센서 및 전송선로 이론을 이용한 2선 평행 전송선로 센서는 값이 싸고 소형 회전기에 설치할 수 있을 정도의 크기를 지니며, 기본적으로 센서의 구조가 고주파 웨이브가이드로서 고주파용 센서로 적합하다. 또한 저주파 신호를 검출하기 위한 센서로 로고우스키 코일 형태의 U 타입 센서는 와전류를 검출하는 센서로서 슬롯 외부에 설치 되어야 한다. 이러한 U 타입 센서와 마이크로스트립 센서 또는 2선 평행 전송선로를 동시에 설치할 경우 저, 고주파를 효과적으로 검출할 수 있다.

  • PDF

Data Acquisition and Statistical Processing of Insulation Resistance for High-Power Cables in Operation (운전 중 고전력 케이블의 절연저항 데이터의 취득과 통계적 처리 방법)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.181-186
    • /
    • 2018
  • With progress in industrialization, facilities for generating, delivering, and receiving high levels of electric power are in great demand. The scale of electric power equipment is increasing in both size and complexity. This has contributed to the development of our modern, high-tech and information-based society. However, if the generation of electric power is suspended due to unexpected accidents at power facilities or power stations, a range of equipment the operations of which are dependent on electric power can be damaged, causing substantial socioeconomic losses in an industrial society. A great deal of time and money would be expended to repair damaged facilities at a power station, causing enormous economic loss. In order to detect the deterioration processes of power cables, and to prevent the destruction of power cables, the operation status of power cables should be monitored on a regular basis. We studied the method in order to improve accuracy and reliability for diagnosising the junction where accident occurs frequently. We present the method of data acquisition and statistical processing.