• 제목/요약/키워드: On-Line Dynamic Security Assessment

검색결과 8건 처리시간 0.019초

온라인 과도안정도 평가를 위한 새로운 불안정모드 선정 알고리즘 (A New Algorithm for Unstable Mode Decision in the On-line Transient Stability Assessment)

  • 장동환;김정우;전영환
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1123-1128
    • /
    • 2008
  • The necessity of online dynamic security assessment is getting apparent under Electricity Market environments, as operation of power system is exposed to more various operating conditions. For on-line dynamic security assessment, fast transient stability analysis tool is required for contingency selection. The TEF(Transient Energy Function) method is a good candidate for this purpose. The clustering of critical generators is crucial for the precise and fast calculation of energy margin. In this paper, we propose a new method for fast decision of mode of instability by using stability indices and energy margin. The method is a new version of our previous paper.[1] Case studies are showing very promising results.

전력계통 동태 안전성 평가에 코호넨 신경망 적용 연구 (An Application of Kohonen Neural Networks to Dynamic Security Assessment)

  • 이광호;박영문;김광원;박준호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.253-258
    • /
    • 2000
  • This paper presents an application of Kohonen neural networks to assess the dynamic security of power systems. The dynamic security assessment(DSA) is an important factor in power system operation, but conventional techniques have not achieved the desired speed and accuracy. The critical clearing time(CCT) is an attribute which provides significant information about the quality of the post-fault system behaviour. The function of Kohonen networks is a mapping of the pre-fault system conditions into the neurons based on the CCTs. The power flow on each line is used as the input data, and an activated output neuron has information of the CCT of each contingency. The trajectory of the activated neurons during load changes can be used in on-line DSA efficiently. The applicability of the proposed method is demonstrated using a 9-bus example.

  • PDF

안정도 지수와 에너지 마진을 이용한 불안정 발전기의 clustering 법 (A Novel Method for Clustering Critical Generator by using Stability Indices and Energy Margin)

  • 장동환;정연재;전영환;남해곤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.441-448
    • /
    • 2005
  • On-line dynamic security assessment is becoming more and more important for the stable operation of power systems as load level increases. The necessity is getting apparent under Electricity Market environments, as operation of power system is exposed to more various operating conditions. For on-line dynamic security assessment, fast transient stability analysis tool is required for contingency selection. The TEF(Transient Energy Function) method is a good candidate for this purpose. The clustering of critical generators is crucial for the precise and fast calculation of energy margin. In this paper, we propose a new method for fast decision of mode of instability by using stability indices. Case study shows very promising results.

선로조류를 이용한 전력계통 동태 안전성 평가 연구 (A Study on Dynamic Security Assessment by using the Data of Line Power Flows)

  • 이광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권2호
    • /
    • pp.107-114
    • /
    • 1999
  • This paper presents an application of artificial neural networks(ANN) to assess the dynamic security of power systems. The basic role of ANN is to provide assessment of the system's stability based on training samples from off-line analysi. The critical clearing time(CCT) is an attribute which provides significant information about the quality of the post-fault system behaviour. The function of ANN is a mapping of the pre-fault, fault-on, and post-fault system conditions into the CCT's. In previous work, a feed forward neural network is used to learn this mapping by using the generation outputs during the fault as the input data. However, it takes significant calculation time to make the input data through the network reduction at a fault as the input data. However, it takes significant calculation time to make the input data through the network reduction at a fault considered. In order to enhance the speed of security assessment, the bus data and line powers are used as the input data of the ANN in thil paper. Test results show that the proposed neural networks have the reasonable accuracy and can be used in on-line security assenssment efficiently.

  • PDF

온라인 동적 안전도평가 시스템의 개발 (Development of On-line Dynamic Security Assessment System)

  • 남해곤;송성근;심관식;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.73-76
    • /
    • 2001
  • This paper presents a new systematic contingency selection, screening and ranking method for on-line transient security assessment. Transient stability of a particular generator is influenced most by fault near it. Fault at the transmission lines adjacent to the generators are selected as contingency. Two screening methods are developed using the sensitivity of modal synchronizing torque coefficient and computing an approximate critical clearing time(CCT) without time simulation. The first method, which considers only synchronizing power, may mislead in some cases since it does not consider the acceleration power. The approximate CCT method, which consider both the acceleration and deceleration power, worked well. Finally the Single Machine Equivalent(SIME) method is implemented using IPLAN of PSS/E for detailed stability analysis.

  • PDF

전력계통의 미소신호안정도 상정사고 해석 (Contingency Analysis for Small Signal Stability of Power Systems)

  • 심관식;김용구;문채주
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.127-137
    • /
    • 2003
  • 논문에서는 대규모 계통의 미소신호안전도 평가 및 해석을 위해 고유치 감도/perturbation 이론에 근거한 상정사고 지표를 제안하였으며 이를 실제 계통에 적용한 결과를 기술하였다. 선로정수와 제어기점수에 대한 미소신호 안정도 상정사고 지표를 제시하였고 이로부터 심각한 저주파진동 문제를 발생할 수 있는 파라메타들을 선택하였다. 또한 각 발전기의 발전량 증감에 대한 고유치 변화로부터 미소신호안정도 상정사고를 일으킬 수 있는 발전기들을 선택하였다. 이 논문에서는 모든 결과들을 2000년 KEPCO 실계통의 시간영역해석과 비교 검증하여 제안한 미소신호안정도 상정사고 해석법이 정확함을 확인하였다.

온라인 과도안정도 판정을 위한 상정사고 고속 스크리닝 알고리즘 개발 (A Fast Screening Algorithm for On-Line Transient Stability Assessment)

  • 이종석;양정대;이병준;권세혁;남해곤;추진부;이경극;윤상현;박병철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권5호
    • /
    • pp.225-233
    • /
    • 2001
  • SIME(SIngle Machine Equivalent) method has been recognized as a useful tool to determine transient stability of power systems. In this paper, SIME method is used to develop the KEPCO transient stability assessment (TSA) tool. A new screening algorithm that can be implemented in SIME method is proposed. The salient feature of the proposed screening algorithm is as follows. First, critical generators are identified by a new index in the early stage of the time domain simulation. Thus, computational time required to find OMIB(One Machine Infinite Bus) can be reduced significantly. Second, clustering critical machines can be performed even in very stable cases. It enables to be avoid extra calculation of time trajectory that is needed in SIME for classifying the stable cases. Finally, using power-angle trajectory and subdividing contingency classification have improved the screening capability. This algorithm is applied to the fast TSA of the KEPCO system.

  • PDF

안정도 지수와 에너지 마진을 이용한 불안정 발전기의 clustering 법 (A Novel Method of Clustering Critical Generator by using Stability Indices and Energy Function)

  • 장동환;정연재;전영환;남해곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.136-139
    • /
    • 2005
  • On-line dynamic security assessment is becoming more and more important for the stable operation of power systems as load level increases. The necessity is getting apparent under Electricity Market environments due to more various operating conditions. Fast transient stability analysis tool is required for contingency selection. The TEF(Transient Energy Function) method is a good candidate for this purpose. The clustering of critical generators is crucial for the precise and fast calculation of energy margin. In this paper, we propose a new method for fast decision of mode of instability by using stability indices. Case study shows very promising results.

  • PDF