• 제목/요약/키워드: On-Line Application

검색결과 2,202건 처리시간 0.031초

HVAC에 의한 On-line, Off-line PD 모니터링 (On-line and Off-line Partial Discharge Monitoring System with HVAC Testing)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

두께가 다른 두 용접판재 성형에 있어서 블랭크 설계 및 용접선 이동에 대한 유한요소법의 역추적기법 적용 (Application of the Backward Tracing Scheme of Finite Element Method to Tailored Blank Design and Welding Line Movement in Sheet Metal Forming)

  • 구태완;최한호;강범수
    • 소성∙가공
    • /
    • 제9권5호
    • /
    • pp.453-462
    • /
    • 2000
  • Tailor-welded blanks are used for forming of automobile structural skin components. The main objective of this study is to achieve weight and cost reduction in manufacturing of components. For successful application of tailor-welded blanks, design of initial welded blanks and prediction of the welding line movement are critical. The utilization of the backward tracing scheme of the finite element method shows to be desirable in design of initial welded blanks for net-shape production and in prediction of the welding line movement. First the design of the initial blank in forming of welded thick sheet with isotropy is tried, and it appears successful in obtaining a net-shape stamping product. Based on the first trial approach, the backward tracing scheme is applied to anisotropic tailored blanks. The welding line movement is also discussed.

  • PDF

애니메이션 캐릭터를 이용한 토들러복 디자인 연구 - 아기공룡 둘리를 중심으로 - (Design Development for Toddler Apparel Line using Animation Characters - Focusing on ″Little Dinosaur Dooly″ -)

  • 하승연;이연희
    • 복식문화연구
    • /
    • 제12권1호
    • /
    • pp.104-120
    • /
    • 2004
  • Animation character market in Korea has been dominated by licensed characters (e.g., Walt Disney′s) of which market share is 80%. While market share for Korean characters such as "Mashimaro" and "Little Dinosaur Dooly" is increasing, the application of such characters to fashion products is still limited. For the development of the Korean character market, application of original animation characters should be applied to various fashion products. The main purpose of this study was to design toddler apparel line using "Little Dinosaur Dooly," one of the most popular domestic animation characters. The design focus is the green color of Dooly because the color is the distinctive concept of the brand. Results of the study indicated that developing toddler apparel line with a Korean animation character was a meaningful attempt, as imported licensed characters were dominant in domestic fashion market. The key differentiating factor was the use of green color. In addition, use of various supporting characters, namely Dooly′s friends, demonstrated potential line extension forming animation character groups similar to Warner Brothers′"Looney Tunes."

  • PDF

Open-Short 방식의 임피던스 측정에 의한 분포정수의 보정 (A LOSSY LINE DISTRIBUTED PARAMETERS CALCULATION USING DATA OF OPEN-SHORT IMPEDANCE MEASURING METHOD)

  • ;조기연;변영복;서정일;김은수;김태진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2553-2555
    • /
    • 1999
  • The paper contains design formulas and an execution algorithm for calculation of distributed parameters as well as wave and impedance parameters of a uniform transmission line using data of the line input impedance measurements by the OPEN-SHORT method. In difference from published before works on the OPEN-SHORT method application for line parameters determination, in which the lines with small losses are considered /1-3/, the obtained formulas allow to calculate parameters of transmission lines with arbitrary losses. It opens new possibilities of the OPEN-SHORT method utilization for development and application of the probe - type lossy dielectric media parameters meters based on transmission lines, including probe-type moisture material meters.

  • PDF

철도종합시험선 구축 필요성 (Establishment of Railway Test Line - focusing on the needs & plan)

  • 문제우;김태욱;이명석;정장용;김종태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.776-781
    • /
    • 2008
  • In this paper, comments on the needs of establishment of railway test line - capable of mid and long term performance evaluation of vehicle/infra/electricity/signal component/system - are described. Based on the previous studies, national/social/economic needs, the states of similar lines of foreign countries, concept of test line, and basic application plan are summarized. Especially, core things needed to the establishment of test line are commented.

  • PDF

점적 급액 방식에서의 양액 공급량 예측 프로그램의 개발 (Development of A Computer Simulation Program of Emitter Discharges for Trickle Application)

  • 오길근;류관희;홍순호
    • Journal of Biosystems Engineering
    • /
    • 제20권4호
    • /
    • pp.390-396
    • /
    • 1995
  • This study was conducted to develop a computer simulation program for trickle application of nutrient solution. A computer simulation program using finite element method was developed to evaluate discharges of emitters on trickle application. The uniformity of application for two different lateral line lengths and three application methods was evaluated by the computer simulation program. The results of this study are as follows. 1. A computer simulation program was developed to determine emitter discharges from a trickle application system and pressures at emitter positions by finite element method and to design a uniform trickle application system. 2. The simulation program developed was verified by experiment. The root mean square error between experimental data and simulated data was 1.1% on the average discharge and it was found that the computer simulation program was an effective tool for the design of a trickle application system of nutrient solution. 3. The uniformity of trickle application system was evaluated for three different methods of supplying nutrient solution with different lateral line lengths. The best uniformity was obtained from the method, which supplies nutrient solution from both ends alternatively for the same period of time.

  • PDF

시계열 데이터를 이용한 새로운 온라인 미소신호안정도 평가 방법과 적용 (A New Method for Assessing On-line Small-signal Stability and its Application)

  • 김동준;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.387-389
    • /
    • 2006
  • This paper describes new on-line small signal stability assessment and its application using the time series simulated phasor measurement data. Using FFT technique and optimization method, the suggested method can effectively identify all of mode frequencies involved in measured data and calculate the damping ratio with accuracy.

  • PDF

원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구 (A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants)

  • 이승표;김진회
    • 한국압력기기공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

수산소 혼합가스를 이용한 선상가열 특성 (The Characteristics of Line Heating Using Hydrox Gas)

  • 김홍건;곽이구
    • 한국생산제조학회지
    • /
    • 제20권4호
    • /
    • pp.407-411
    • /
    • 2011
  • The technology of line heating has evolved in various methods. Among them, fossil fuels like ethylene gas and LPG(Liquid Petroleum Gas) are widely used due to their simple utility. In the meantime, the technology implementing high frequency for line heating has also been developed continually, but its manufacturing technology or application includes lots of problems by now. One of the main characteristics of line heating using conventional technolob'Y is the quenching effect followed by heating process. On the other hand, hydrox gas which is mixed by hydrogen and oxygen is a prominent candidate for an application without above shortcomings. Especially, it is found that line heating using hydrox gas is tremendously effective taking low cost as well as low noise. In this paper, a small cell with high efficiency which can minimize installing space is developed to deal with the problem installing in narrow place. Experiments to prove the validation, efficiency and effectiveness is carried out by characterizing in the line heating of steel. It is found that the energy saving of using hydrox gas for line heating is significant and that the deviation performance is reduced by 78~89%. Furthermore, the noise is also reduced as amount of 18.3% though the heating time is not too different.

송전선용 비접촉식 커플러의 설계와 적용연구 (Study on Design and Application of an Inductive Coupler for Power Transmission Line)

  • 김현식;이동철;김민호;이진;오영우;민병훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.234-239
    • /
    • 2010
  • An inductive coupler, which feeds communication to the electric power transmission line, is required to establish Power Line Communication(PLC). The electro-magnetic property of magnetic core and design technology for coupler are very important to manufacture an inductive coupler for power transmission line. The magnetic core with superior electro-magnetic property was manufactured by using nanocrystalline alloy and an inductive coupler, which can operate at the maximum 2,000 A current, was designed and manufactured by establishment of current saturation, signal out winding, and electromagnetic simulation in this study. Communication speed of 14 Mbps in 600 meter communication distance of the real electric power transmission line was obtained by using the inductive coupler and application possibility of the inductive coupler for the electric power transmission line was certified.