• Title/Summary/Keyword: On/off cycle

Search Result 371, Processing Time 0.025 seconds

Scheduling of Concurrent Transactions in Broadcasting Environment

  • Al-Qerem, Ahmad;Hamarsheh, Ala;Al-Lahham, Yaser A.;Eleyat, Mujahed
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.4
    • /
    • pp.1655-1673
    • /
    • 2018
  • Mobile computing environment is subject to the constraints of bounded network bandwidth, frequently encountered disconnections, insufficient battery power, and system asymmetry. To meet these constraints and to gain high scalability, data broadcasting has been proposed on data transmission techniques. However, updates made to the database in any broadcast cycle are deferred to the next cycle in order to appear to mobile clients with lower data currency. The main goal of this paper is to enhance the transaction performance processing and database currency. The main approach involves decomposing the main broadcast cycle into a number of sub-cycles, where data items are broadcasted as they were originally sequenced in the main cycle while appearing in the most current versions. A concurrency control method AOCCRBSC is proposed to cope well with the cycle decomposition. The proposed method exploits predeclaration and adapts the AOCCRB method by customizing prefetching, back-off, and partial backward and forward validation techniques. As a result, more than one of the conflicting transactions is allowed to commit at the server in the same broadcast cycle which empowers the processing of both update and read-only transactions and improves data currency.

Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater (심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석)

  • JUNG, H.;HWANG, S.W.;LEE, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

Joint Control of Duty Cycle and Beacon Tracking in IEEE 802.15.4 LR-WPAN (IEEE 802.15.4 저속 WPAN에서 듀티 사이클과 비콘 추적의 통합 제어)

  • Park, Sung-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.9-16
    • /
    • 2016
  • Since most of devices in the IEEE 802.15.4 LR-WPAN are expected to operate on batteries, they must be designed to consume energy in a very conservative way. Two energy conservation algorithms are proposed for the LR-WPAN: DDC (Dynamic Duty Cycle) and DBT (Dynamic Beacon Tracking). The DDC algorithm adjusts duty cycle dynamically depending on channel conditions. The DBT algorithm switches beacon tracking mode on and off adaptively depending on traffic conditions. Combining the two algorithms reduces energy consumption more efficiently for a wide range of input loads, while maintaining frame delivery ratio and average delay at satisfactory levels.

Surface Encoder Based on the Half-shaded Square Patterns (HSSP)

  • Lee, Sang-Heon;Jung, Kwang-Suk;Park, Eui-Sang;Shim, Ki-Bon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.82-84
    • /
    • 2008
  • A surface encoder based on the Half-shaded square pattern (HSSP) is presented. The HSSP working as reference grid is composed of the straight lines which are easy to be fabricated and make measuring time short. Since the periodic cell is separated in ON/OFF by the $45^{\circ}$ straight line, the duration from the starting point of scanning to the first rising edge and the duty cycle of the pulse train vary with respect to the position of the starting point. And the relationship between X and Y position and the duration, and duty cycle is described in the simple linear equation. Therefore, it is possible to measure X and Y position with the measured duration and duty cycle without calculating load. Through the test set-up, the feasibility of the proposed surface encoder was verified. Also the future works for improvement of performance were suggested.

Development of Control Method for Air-Conditioner as the Resources of DLC (직접부하제어자원으로서 에어컨 주기제어 방법론 개발)

  • Doo, Seog-Bae;Kim, Jeoung-Uk;Kim, Hyeong-Jung;Kim, Hoi-Cheol;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.145-147
    • /
    • 2005
  • This paper presents a methodology for satisfying the thermal comfort of Indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. KEPCO(Korea Electric Power Corporation) use the fixed duty cycle control method regardless of the indoor thermal environment. This method has disadvantages that energy saying depends on the set-point value of the Air-Conditioner and DLC has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. A variable duty cycle estimates the PMV(Predict Mean Vote) at the next step with a predicted temperature and humidity coming from the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. The proposed methodology uses the historical real data of Sep. 7th, 2001 from a classroom in seoul to verify the effectiveness of the variable duty cycle method comparing with fixed duty cycle. The result shows that the variable duty cycle reduces the peak demand to 2.6times more than fixed duty cycle and increases the load control ratio by 8% more. Based on the variable duty cycle control algorithm, the effectiveness of DLC is much more improved as compared with the fixed duty cycle.

  • PDF

A Study on the Propensity to Consume and Housing Characteristics According to Life Cycle (생활주기(life cycle)에 따른 소비성향 및 주거관련 특성에 관한 연구)

  • Seo, In-Joo;Jung, Ji-Young;Han, Yeon-Soon
    • Journal of Family Resource Management and Policy Review
    • /
    • v.16 no.1
    • /
    • pp.85-101
    • /
    • 2012
  • This study aims to identify the propensity to consume and housing characteristics according to life cycle as the main independent variable. It also tries to understand the consumption power and housing style of each cycle and analyze whether there are differences between each life cycle, ultimately aiming to match the propensity to consume and housing style with each cycle. For empirical analysis, on and off-line surveys of 488 people were collected and analyzed by cross analysis, factor analysis and analysis of variance. The prime research findings are as follows: First of all, factor analysis on propensity to consume showed four main sub-factors as rational consumption, conspicuous consumption, trend consumption, and status consumption. Secondly, current and preferred housing styles ranked from modern, natural, casual, classic and romantic, which proved that people are currently housed in preferred housing styles. Thirdly, in case of housing-related characteristics of life cycles, the size of the house increased as the levels progressed, and then decreased at level 6 when the children grew into adulthood. The majority of the population was paying a monthly rent, a few were leasing, and a very few owned their housing. 58% were living in apartments, but in levels 1-2, more were living in row houses and high-rise residential buildings, while in level 6 it was detached houses. Fourthly, the propensity to consume according to life cycle tended to shift from conspicuous and trend-based consumption to rational consumption as the cycles progressed. Fifthly, the preferred housing styles were modern and natural styles, regardless of life cycle. These study results can be applied to product development and marketing activities based on their accurate analysis of customers' needs, which can thus bring further customer satisfaction.

  • PDF

NOx Emission Characteristics of Diesel Passenger Cars Met Euro 6a and 6b Regulations on Off-cycles (Off-cycle에서 Euro 6a 및 6b 규제 만족 디젤 자동차의 NOx 배출 특성)

  • Kim, Sung-Woo;Lim, Jae-Hyuk;Kim, Ki-Ho
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.68-78
    • /
    • 2017
  • Major countries have tighten their NOx regulation of diesel passenger cars. In the case of the EU, the regulation has been toughen up to 6.25 times since 2000. Despite the regulation the NOx concentration of the ambient has not been reduced proportionally. Futhermore, some manufacturers were disclosed using a defeat device for meeting the regulation illegally. As these issues, to reduce NOx emission practically, Korea and the EU introduced the real-world driving emission(RDE) regulation and the test method that will be applied after 2017. Also, the US has used the test equipment(PEMS) to detect a defeat device. In this paper, for the regulation to make a soft landing in Korea, 4 diesel passenger cars which met Euro 6a~6b regulation and were equipped with LNT/SCR were tested at a chassis dynamometer with environmental chamber applying the off-cycles(FTP, US06, SC03, HWFET and CADC) and several ambient condition(-7 and $14^{\circ}C$) as well as certification mode(NEDC, WLTC@ $23^{\circ}C$). The result of the test showed that the ambient temp. and the engine load as a test mode impacted the NOx emission of the cars while the vehicles with SCR emitted NOx lower than with LNT. Additionally, to propose an effective RDE test method, the above result was compared with the results of the other papers which tested RDE using the same cars.

Conceptual Study of an Exhaust Nozzle of an Afterburning Turbofan Engine (후기연소기 장착 터보팬엔진의 배기노즐 개념연구)

  • Choi, Seongman;Myong, Rhoshin;Kim, Woncheol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.3
    • /
    • pp.62-69
    • /
    • 2014
  • This paper presents a preliminary study of a convergent divergent nozzle in an afterburning turbofan engine of a supersonic aircraft engine. In order to design a convergent divergent nozzle, cycle model of a low bypass afterburning turbofan engine of which thrust class is 29,000 lbf at a sea level static condition is established. The cycle analysis at the design point is conducted by Gasturb 12 software and one dimensional gas properties at a downstream direction of the turbine are obtained. The dimension and configuration of an model turbofan engine are derived from take-off operation with wet reheat condition. The off-design cycle calculation is conducted at the all flight envelope on the maximum flight Mach number of 2.0 and maximum flight altitude of 15,000 m.

Improvement of Lift-off Tests via Field Evaluation of Residual Load in Ground Anchor (현장 잔존긴장력 평가를 통한 리프트오프 시험 방법 개선)

  • Song, minkwon;Park, Seong-yeol;Lee, Sangrae;Cho, Wanjei
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.5
    • /
    • pp.43-51
    • /
    • 2019
  • At present, the ground anchor method is commonly applied to securing the slope stability in Korea. The ground anchor is reported to decrease in tensile load due to aging and environmental influences with time such as corrosion, relaxation, creep and so on. In Korea, the lift-off test is performed for the periodic inspection or cases when the symptoms of deterioration on anchors and the residual tensile load of the anchors is checked. However, the current lift-off test standard (MOLIT, 2010) is not fully specified in details. In this study, the factors affecting the lift-off test were investigated based on the previous research and foreign standards and lift-off tests were performed with consideration for the loading and unloading cycle, load increment method, and tensioning tendon method. Based on the results, this paper proposes improved testing and evaluation procedures of the lift-off test considering the workability and time limits in the field.

Constrained NLS Method for Long-term Forecasting with Short-term Demand Data of a New Product (제약적 NLS 방법을 이용한 출시 초기 신제품의 중장기 수요 예측 방안)

  • Hong, Jungsik;Koo, Hoonyoung
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.38 no.1
    • /
    • pp.45-59
    • /
    • 2013
  • A long-term forecasting method for a new product in early stage of diffusion is proposed. The method includes a constrained non-linear least square estimation with the logistic diffusion model. The constraints would be critical market informations such as market potential, peak point, and take-off. Findings on 20 cases having almost full life cycle are that (i) combining any market information improves the forecasting accuracy, (ii) market potential is the most stable information, and (iii) peak point and take-off information have negative effect in case of overestimation.