• Title/Summary/Keyword: On/off Solenoid Valve

Search Result 84, Processing Time 0.031 seconds

A Study on Energy Saving Algorithm of Pneumatic Regulator with Modified PWM Driven Method

  • Kim, H.S.;Ahn, K.K.;Lee, B.R.;Yun, S.N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1339-1342
    • /
    • 2005
  • The development of an accurate and energy saving pneumatic regulator that may be applied to a variety of practical pressure control applications is described in this paper. A novel modified pulse width modulation(MPWM) valve pulsing algorithm allows the pneumatic regulator to become energy saving system. A comparison between the system response of conventional PWM algorithm and that of the modified PWM(MPWM) algorithm shows that the control performance is almost the same, but energy saving is greatly improved by adopting this new MPWM algorithm. The effectiveness of the proposed control algorithm is demonstrated through experiments with various reference trajectories.

  • PDF

A Study on Pressure Control of Pneumatic Regulator using Modified PWM Algorithm (개량된 PWM 알고리즘을 이용한 공압 레귤레이터의 압력제어에 관한 연구)

  • Kim HyoungSeog;Ahn KyoungKwan;Lee ByungRyong;Yun SoNam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.64-70
    • /
    • 2005
  • The development of an accurate and energy saving pneumatic regulator that may be applied to a variety of practical pressure control applications is described in this paper. A novel modified pulse width modulation(MPWM) valve pulsing algorithm allows the pneumatic regulator to become energy saying system. A comparison between the system response of conventional PWM algorithm and that of the modified PWM(MPWM) algorithm shows that control performance is almost the same, but energy saving is greatly improved by adopting this new MPWM algorithm. The effectiveness of the proposed control algorithm are demonstrated through experiments with various reference trajectories.

Position servo control of a PR type pneumatic manipulator (PR형 공압 머니퓰레이터의 위치서보제어)

  • Lim, Seung-Cheol;Eao, Yun-Beom
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.10
    • /
    • pp.1619-1625
    • /
    • 1997
  • This paper concerns a 2-axis PR type pneumatic manipulator system translating in vertical and rotating in horizontal directions. A simplified linear model is mathematically formulated similar to the pneumatic acturators in dynamic responses in order to devise an appropriate position control scheme. A PD controller preceding the on/off solenoid valve turns out not only economical but also effective in reducing rise time and amplitude of limit cycles, if its control gains are determined on the basis of frequency response. And, additional implementation of symmetric or asymmetric deadband at the PD controller output greatly helps minimize valve opening numbers, positional error, and undesirable direction-dependent property due to the gravitational load. Such a control concept is synthesized through numerical simulations and next applied to the experimental set-up, featuring enhanced positional servo characteristics.

A Study on Stability Analysis of Hydraulic System Using High Speed On-Off Valves (고속전자밸브를 사용한 유압시스템의 안정성 해석에 관한 연구)

  • 유태재
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.412-420
    • /
    • 2003
  • This study describes the merits of PWM control of hydraulic system using high speed on-off valves. Generally, Electro-hydraulic valves can be classified into two classification: valves which are controlled by analog signal and which are controlled by digital. The former includes hydraulic servo valves and proportional valves which require A/D converters as interface to digital computer and too costly and sensitive to oil contamination because of complexity in structures. The latter includes high speed on-off valves which do not require A/D converters because they are normally operated in a pulse width modulation(PWM) method, and are low in price and robust to oil contamination because of their simple structures. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using 2/2way high speed on-off valves and to give a criterion for the stability of this system. The nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are simulated.

Sensing performance evaluation under various environment condition of stroke sensing cylinder using magnetic sensor (자기센서를 이용한 위치검출 실린더의 환경변화에 따른 성능평가)

  • 김성현;이민철;양순용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.636-639
    • /
    • 1996
  • We have developed a part of hydraulic stroke sensing cylinder using magnetic sensor that can detect each position under severe construction fields. In this paper, for evaluating the developed cylinder under various environment condition, thermal control systems and two hydraulic systems to be coupled consist of. The former is composed of an heater case, temperature sensor, and interface circuits which include SCR(silicon controlled rectifier) for the control of the voltage's phase. The latter is composed of an hydraulic cylinder for position control with solenoid valve (ON/OFF motion) and a load cylinder with proportional reducing valve. To obtain the various performance evaluation, it is carried out under high temperature condition in thermal system controlled by using Ziegler-Nichols PID tuning method and artificial disturbances such as impulse or constant force. The results show that the developed cylinder has good performance under the various environment condition.

  • PDF

유압 위치제어 시스템의 단속적 제어방법에 관한 연구 I

  • 장효환;안병홍;이춘호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.3
    • /
    • pp.465-472
    • /
    • 1987
  • Two kinds of discontinuous control methods i, e., simple on-off(SOF) control and pulsating on-off(POF) control methods are implemented and compared each other for a low cast hydraulic position-control system which utilizes a solenoid-operated directional valve instead of a servovalve. Experimental work was carried out to investigate effects of control parameters and loading conditions on step response characteristics of the system for each control method. The results show that much higher accuracy and much better transient response characteristics can be achieved by POF controller than those by SOF controller. The results may be used as basic data in the selection of control parameters as well as in the design of the hydraulic position-control system.

개폐식 밸브를 이용한 공압실린더의 위치제어

  • 홍지중;이정오;홍예선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.380-384
    • /
    • 1992
  • The position control of a pneumatic cylinder suing low cost on-off valves is studied. The valve control band(VCB) was proposed toget fast response and toprevent solenoid valves from unnecessary switching at the beginning of response. A learning algorithm was used to compensate the nonlinearity and complexity in mathematical modelling of pheumatic on-off controlled positioning systems. In this algorithm, the desired performance index and modified learning rate, were proposed to improvespeed and convergence of learning control. It is shown experimentally that the proposed algorithm is robust to changes of system parameters: the setting time less than 1.0 sec and the error bound of .+-. 0.1 mm can be obtained. The effects of supply pressure, size of switching valves and the effect of multiple valves are discussed, and computer simulation onthe dynamic performances of the pneumatic system is also presented.

Improving Hydraulic System Design by Analysis Model of a Self-propelled Spinach Harvester (자주식 시금치 수확장치 해석모델을 활용한 유압시스템 개선 설계 제안)

  • Noh, Dae Kyung;Lee, Dong Won;Lee, Jong Su;Jang, Joo Sup
    • Journal of Drive and Control
    • /
    • v.19 no.1
    • /
    • pp.69-75
    • /
    • 2022
  • This study aimed to develop solutions for the intermittent performance deterioration of self-propelled spinach harvesters through analysis model. The study was conducted in the following manner. First, changes in performance deterioration and surplus flow, which result from oil temperature changes, were analyzed by simulating actual sequential harvesting movements, which involve driving with actuators operated simultaneously, by analysis model developed in a previous study. Second, fundamental solutions for surplus flow problems were presented. Third, the solutions were applied to a virtual environment to present their practicality and quantitative effects. The two solutions based on the study results were as follows. First, a closed center-type directional control valve was applied to the hydraulic circuit. Second, an unloading system was set up through an on-off solenoid valve.

Performance Increase for a 2 kW Open Cathode Type Fuel Cell Using Temperature/Humidity Control (2 kW급 개방 캐소드형 연료전지 출력 향상을 위한 온습도 제어)

  • YUAN, WEIWEI;CHOI, MIHWA;YANG, SEUGRAN;KIM, YOUNG-BAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.369-376
    • /
    • 2017
  • Temperature and humidity regulations of an open-cathode PEM fuel cell with balance of plant (BOP) are developed in this study. The axial fan, a bubble humidifier, set of solenoid valves and a controller are used to perform temperature and humidity control simultaneously. A fuzzy controller is designed, and it shows its superiority in real-time controlling for strong non-linear dynamical fuel cell system. The axial fan speed is used for temperature control and solenoid valve on/off signal of the bubble humidifier is used for humidity control. The axial fan speed is controlled to keep the fuel cell temperature within the desired point. Meanwhile, the bubble humidifier is utilized to moisture hydrogen to manage the water content of membrane. The results show that the proposed fuzzy controller effectively increases the output power of 10% for a PEM fuel cell.

Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels -II -Design of a Remote Steering System- (소형 연근해 어선의 조업 시스템 개선에 관한 연구-II -원격 조타 시스템의 설계-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • A combination steering system was designed to provide the flexibility in controlling the steering wheel in fishing operations of the inshore and coastal fishing vessels. The designed steering system basically is consisted of three driving units, such as a electrically driven hydraulic pump unit with a solenoid control valve, a DC motor driven hydraulic pump unit and a manually driven hydraulic pump unit, and two controllers to provide remote steering on the deck, respectively. The steering torque was measured and analyzed to investigate the dynamic performance of the developed steering system. The steering system showed excellent linearity between the working pressure of cylinder and the torque of rudder post in case of increasing in rudder angle from $5^{\circ} to 35^{\circ}$ that is, the steering torque increased from $10.4 kgf{\cdot}m$ to $105.3 kgf{\cdot}m$ and then the working pressure of cylinder fluctuated from 6.3 kgf/cm super(2) to 16.4 kgf/cm super(2). The steering time of 3.2 sec in remote hydraulic steering by the on/off solenoid valve control was much faster than 13.2 sec in the manual steering by the helmsman and 11.6 sec in the electric steering by a DC motor, and then it was verified that operation of one unit does not affect other units in combination steering system in any way. Furthermore, the developed steering system can be remotely controlled in multiple stations of the deck during the fishing operation and the automatic pilot steering unit can be used to add hydraulic steering.

  • PDF