• 제목/요약/키워드: Oltc

검색결과 33건 처리시간 0.028초

OLTC를 고려한 고온 초전도 변압기의 설계 (Design of an HTS Transformer with OLTC)

  • 최지훈;이승욱;박명진;주형길;한진호;한송엽;최경달
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.67-71
    • /
    • 2007
  • HTS transformers which have been developed until now had only fundamental structures. Among the auxiliary functions of conventional transformers, voltage regulating is the most important one. For the voltage regulation, conventional transformers are equipped with on load tap changers (OLTCS). In this paper, we describe the possibility of the HTS transformer with OLTC. For the case study, we designed a single phase 33 MVA HTS transformer with OLTC. It is one of three individual HTS transformers which composes a 3 phase, 100 MVA transformer. It is expected to substitute for a 3 phase, 60 MVA conventional transformer in Korea. The parameters of an HTS transformer are varied due to the gap length between primary and secondary windings. The length was decided for the transformer to have the impedance of 12 %. Its size was limited to the one of the conventional transformer. The characteristics of the HTS transformer were analyzed in both case of having OLTC and not.

변전소내 지역정보를 이용하여 안정도 향상을 위한 실시간 OLTC 및 커패시터 협조제어 알고리즘 (On-line coordination control of OLTC and Switched Shunt for enhancement of stability using local data in substation)

  • 강상균
    • 한국산업정보학회논문지
    • /
    • 제17권7호
    • /
    • pp.119-125
    • /
    • 2012
  • 본 논문은 변전소 내에서 취득된 데이터만을 이용하여 전계통 전압안정도를 확보하기 위한 실시간 변전소내 OLTC(On-Load Tap Changer)와 S.S(Switched Shunt)와의 협조제어 알고리즘을 제안하고자 한다. 전압레벨을 일정한 값으로 유지시키기 위해서 동작하는 OLTC의 제어를 잘못하게 된다면 오히려 계통의 안정도(전압안정도) 를 해치는 결과를 나타낼 수 있다. 이 논문에서는 단일 변전소에서 취득된 데이터만으로 전체 시스템의 상태를 판단할 수 있는 Z-index를 이용하였다. Z-index를 이용하여 시스템을 normal 상태와 abnormal 상태로 구분하였고, 각 상태에 따른 협조제어 알고리즘을 제안하였다. 알고리즘 검증을 위해서 Hypersim과 matlab simulink를 이용하였다.

OLTC를 활용한 도시철도 최대전력 감축에 관한 연구 (The study on Reduction of Demand Power in Urban Railway using OLTC)

  • 김한수
    • 한국전자통신학회논문지
    • /
    • 제11권10호
    • /
    • pp.963-968
    • /
    • 2016
  • 논문에서는 도시철도의 변전소의 최대수요전력을 줄이기 위한 새로운 방법으로 OLTC(:On Load Tap Changer)를 갖는 변압기의 사용을 제안한다. 국내의 대부분의 도시철도는 전동차에 필요한 전력을 다이오드 방식으로 정류하며 DC 1500[V]로 공급한다. 변전소가 병렬로 연결되어 있기 때문에 수전전압이 상승하면 정류기 전압도 상승하게 되고 변전소의 최대전력도 증가하게 된다. 시뮬레이션 결과를 통해 본 논문에서 제안하는 방법이 최대수요전력의 증가를 상당히 제한할 수 있음을 보인다.

OLTC를 고려한 33 MVA 초전도 변압기 설계 (Design of a 33 MVA HTS Transformer with OLTC)

  • 최지훈;이승욱;박명진;김우석;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.885-886
    • /
    • 2006
  • We have proposed a 100 MVA, 3 phases, 154 kV class HTS transformer which will substitute for 60 MVA conventional transformer. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding, it makes the cost of the HTS transformer high and the efficiency low. Further more we considered On Load Tap Changer (OLTC) in HTS power transformer. OLTC equipment is required for fitting to a power transformer by which the voltage ratio between the windings can be varied while the transformer is on load. We analyzed the electrical characteristics of the HTS transformer such as magnetic stress and AC loss.

  • PDF

154kV 변전소 전압제어시스템에 대한 연구 (A study on voltage control system for 154kV substation)

  • 정광호;최승일;송재원;김종우;윤병주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.121-123
    • /
    • 2007
  • 본 논문에서는 Shunt capacitor와 OLTC가 함께 설치된 154kV 변전소에서 송출전압을 고려한 두 기기의 협조제어 시스템에 대해 연구하고자 한다. Shunt Capacitor는 전압제어뿐 아니라 외란이 발생할 경우 안정도 제어에 매우 유용한 중요 기기이다. 그러나 비상시 안정도 제어에 참여하기 위해서는 평상운전 시 적정한 운전여유를 확보하고 있어야 한다. 또한 Shunt capacitor와 OLTC의 특성과 상호작용을 고찰하여 Shunt Capacitor의 무효전력 보상 여유를 유지하고 전압의 변동을 방지하면 OLTC의 탭동작을 최소화하여 고장의 요소를 방지하는 협조제어를 제안한다.

  • PDF

마이크로 프로세서를 이용한 탭 절환용 전압조절기의 연구개발 (Research and Development of AVR(Automatic Voltage Regulator) for OLTC(On Load Tap Changer) Using Microprocessor)

  • 김영남;민병권;윤재학;신현주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.710-713
    • /
    • 1992
  • An AVR for OLTC controls motor tap in transformer in order to supply constant power source. Recently for society which is higher informative and more automatic, in our research, the digital AVR for OLTC is developed that can perform more functions and higher functions ( mesurement, display, protection, control ) using microprocessor in a different control method than the conventional AVR. The experiment result is also present.

  • PDF

변전소 조상 설비간의 협조 제어를 위한 EMTP 과도해석모형 개발 (EMTP Simulation for the Dynamic Analysis of a STATCOM-Shunts-OLTC Coordination in Substation)

  • 정기석;백영식;박지호;장병훈;이현철;이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.237_238
    • /
    • 2009
  • This paper proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC. Voltage/Reactive power control has various difficult aspects to control because of analysis and system dynamics error. This coordinative control method suggests practical algorithm regarding system voltage and reactive power status which is easy to implement in substation basis. In normal status, STATCOM-Shunts-OLTC are in operation. The proposed algorithm is tested and verified in EMTP/RV. And this is expected to be applied to control multiple reactive power devices combined with SCADA/EMS system.

  • PDF

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

악관절장애진단에 있어서 동시다층개별화측방단층촬영의 진단효과 (THE DIAGNOSTIC EFFECT OF THE SIMULTANEOUS MULTIFILM INDIVIDUALIZED LATERAL TOMOGRAPHY IN THE DIAGNOSIS OF THE TEMPOROMANDIBULAR DISORDERS)

  • 이우식;박태원
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.235-248
    • /
    • 1991
  • This study was designed to evaluate the diagnostic effect of the simulatneous multifilm individualized lateral tomography in the diagnosis of the temporomandibular disorders. The subjects consisted of 29 patients with symptoms of the temporomandibular disorders. The panoramic view, oblique lateral transcranial radiograph (OLTC) (Hirozontal angulation 0°, Vertical angulation 29°), submentovertex view, and simultaneous multifilm individualized lateral tomographs (SMFI) in centric occlusion (2.5㎜ thickness difference, 5 layers) were taken for the patients. This study compared the findings from each radiographs in the determining of mandibular condylar position with dual linear measurement of the subjective closest posterior and subjective closest anterior interarticular space and in the determining of bony changes on the studied 30 temporomandibular joints (TMJ) with symptoms of the temporomandibular disorders. The results were as follows: 1. The distribution of condylar position of OLTC and 5 layers of SMFI depended on the radiographs (p<0.05). The condylar position and the distribution of condylar position of OLTC were more similar to lateral sections of the SMFI than mesial sections, and in the distribution of the condylar position of SMFI, the more lateral sections of SMFI, the more concentric 2. positions. There were 10 cases in which all layers showed the same condylar position as that of OLTC. There were 3 cases in which no layers showed the same condylar position as that of OLTC. 3. In the SMFI of 30 Temporomandibular joints studied, there is 13 cases in which all five layers represented the same condylar position in the same TMJ and 11 cases in which 4 layers represented the same condylar position in the same TMJ and 6 cases in which 3 layers represented the same condylar position in the same TMJ. So at least 3 layers of SMFI represented same condylar position in the same TMJ. 4. The bony changes were not detected in conventional radiographs on the temporomandibular joint and the bony changes were not detected in simultaneous multifilm individualized lateral tomographs. The bony changes were detected in conventional radiographs on the temporomandibular joint and the bony changes were detected in simultaneous multifilm individualized lateral tomographs. SMFI provided a meams for a three dimensional visualization of the shape, the position and the extent of bony changes of TMJ.

  • PDF

변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구 (A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation)

  • 정기석;장병훈;이현철;이근준;백영식
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.