• Title/Summary/Keyword: Oil Thickness Detection

Search Result 8, Processing Time 0.027 seconds

Oil Spill Detection Mechanism using Single-wavelength LED and CCD (단일 파장의 LED와 CCD를 이용한 유출유 탐지방법)

  • Oh, Sangwoo;Lee, Moonjin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.4
    • /
    • pp.323-329
    • /
    • 2012
  • In this study, a new optical method for oil detection using an analysis the light-absorption image of separate oil-water mixture with a LED illumination is described. To obtain an information about the presence of oil on water and the thickness of oil, the intensity of light-absorption images acquired through CCD is analyzed. To select the optimal wavelength of the light source, the experiment is conducted using several LEDs having four different wavelength. In the case of using a blue LED having 465 nm wavelength, an intensity decreasing tendency of light-absorption image is obvious and clear. To identify the applicability of sensing system at the real sea condition, experiments are conducted as varying the brightness and water surface angle. Through this research, new optical oil detection methodology is proposed using the absorption difference between water and oil with single-wavelength LED and CCD.

Development of a Microwave Radiometer for Remote Sensing of Oil Spills on the Water Surface (수면 기름 유출 원격 탐사용 마이크로파 라디오미터의 개발)

  • Son, Hong-Min;Park, Jin-Woo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.858-867
    • /
    • 2011
  • In this paper, we propose a microwave radiometer for remote sensing of oil spills on the water surface. In order to achieve the development aim of the measurement accuracy within 0.2 mm for oil slicks of 0~4 mm thickness, the requirements of the microwave radiometer and the specifications of its receiver are drawn. From these requirements and specifications, the receiver with high gain, high sensitivity is designed and implemented. The receiver has the bandwidth of 58 MHz, the system gain of 47.3 dB and the sensitivity of 0.46 K at 10.65 GHz. The processes of design and implementation of the receiver are described in this paper. The effectiveness of the proposed microwave radiometer in the measurement of oil slicks is demonstrated experimentally. The results show the microwave radiometer can detect the oil slicks for 0~5 mm thickness within the accuracy of 0.13 mm successfully.

Fabrication and Application of Palladium Coated Fiber-Optic Hydrogen Detection Sensor (팔라듐이 코팅된 광섬유 수소 검출 센서 제작과 응용)

  • Kim, Kwang Taek;Lee, Sang Won;Kim, Dong Geun;Choi, Nu Ri;Lee, Jong Ryeok;Baik, Se Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.3
    • /
    • pp.160-164
    • /
    • 2018
  • We have proposed a hydrogen detection sensor based on a Pd (palladium)-coated, single-mode, optical fiber. The experimental results demonstrated that the sensor could detect hydrogen in air as well as in insulation oil. The influence of Pd film thickness and environmental temperature on response time and sensitivity was analyzed. The reflected optical power at the optical-fiber/Pd interface decreased as the concentration of hydrogen increased, in both air and the insulation oil. The sensor showed 0.75 dB of optical power variation when the concentration of dissolved hydrogen was saturated in the insulation oil.

Development of Dielectric Constant Sensor for Measurementof Lubricant Properties (윤활유 물성 측정을 위한 유전상수 센서 개발)

  • Hong, Sung-Ho;Kang, Moon-Sik
    • Tribology and Lubricants
    • /
    • v.37 no.6
    • /
    • pp.203-207
    • /
    • 2021
  • This study presents the development of dielectric constant sensors to measure lubricant properties. The lubricant oil sensor is used to measure oil properties and machine conditions. Various condition monitoring methods are applied to diagnose machine conditions. Machine condition monitoring using oil sensors has advantage over other machine condition monitoring methods. The fault conditions can be noticed at the early stages by the detection of wear particles using oil sensors. Therefore, it provides an early warning in the failure procedure. A variety of oil sensors are applied to check the machine condition. Among all oil sensors, only one sensor can measure the tendency of several properties such as acidity and water content. A dielectric constant sensor is also used to measure various oil properties; therefore, it is very useful. The dielectric constant is the ratio of the capacitance of a capacitor using that material as a dielectric to that of a similar capacitor using vacuum as its dielectric. The dielectric constant has an effect on water content, contaminants, base oil, additive, and so forth. In this study, the dielectric constant sensor is fabricated using MEMS process. In the fabrication process, the shape, gap of the electrode array, and thickness of the insulation material are considered to improve the sensitivity of the sensor.

Control of Basal Stem Rot Disease in Oil Palm by Supplementation of Calcium, Copper, and Salicylic Acid

  • Bivi, M. Shahul Hamid Rahamah;Paiko, Adamu Saidu;Khairulmazmi, Ahmad;Akhtar, M.S.;Idris, Abu Seman
    • The Plant Pathology Journal
    • /
    • v.32 no.5
    • /
    • pp.396-406
    • /
    • 2016
  • Continuous supplementation of mineral nutrients and salicylic acid (SA) as foliar application could improve efficacy in controlling basal stem rot (BSR) disease in oil palm seedling. It is revealed from the results that the highest disease severity index (58.3%) was recorded in T8 treatments at 9 months after inoculation. The best disease control was achieved by T7 treatments (calcium/copper/SA [Ca/Cu/SA]) (5.0%) followed by T1 (5.5%), T5 (5.8%), T3 (8.3%), T6 (8.3%), T4 (13.3%), and T2 (15.8%) treatments. Continuous supplementation of Ca/Cu/SA was found to be the most effective in controlling the disease and the high performance liquid chromatography results showed the detection of ergosterol at very low concentration in the treated samples. Moreover, the transmission electron microscopy analysis results clearly indicated that T7 treatment was also enhancing lignification, which was responsible for the thickness of the secondary cell walls and middle lamella compared to untreated samples. It was therefore, concluded that continuous supplementation of minerals nutrients and SA could effectively suppress disease severity by reducing ergosterol activity and also improve the process of lignification in the treated plants. Furthermore, this treatment also managed to delay the onset of BSR symptoms and promote the growth of the seedlings and eventually suppress the BSR disease.

Optimization of Manufacturing Condition for Fried Garlic Flake and the Physicochemical Properties (튀긴 마늘 flake 제조조건의 최적화 및 이화학적 특성)

  • Kim, Kyeong-Yee;Lee, Eun-Kyung
    • Korean journal of food and cookery science
    • /
    • v.28 no.6
    • /
    • pp.805-811
    • /
    • 2012
  • This study was carried out in order to optimize the manufacturing condition of fried garlic flakes as well as to investigate the physicochemical properties of the flakes. Fried garlic flake samples were prepared as follows: garlic was sliced by a thickness of 1.5 mm, 2.0 mm, 2.5 mm, which were measured by a thickness gage. The samples were fried in vegetable oil under different temperatures of $140{\sim}150^{\circ}C$, $160{\sim}170^{\circ}C$ and $180{\sim}185^{\circ}C$. The compression strength depending on the height (h) was measured in order to find the thickness effect by the rheometer (force control: 50 N, h: 3.25 mm). Moreover, the sample with 1.5 mm thickness showed crisp phenomena of the split compared with the crush shape of the 2.0 mm and 2.5 mm thick samples. The result of strength for time dependence showed a sample with a thickness of 1.5 mm, which was measured 5~9 times more than the 2.0 mm and 2.5 mm thick samples. We thought the reason that the 1.5 mm sample had less response power equivalent to compression force than the other samples. Alliin has been found to affect the immune responses in the blood, it is a derivative of the amino acid cysteine and is also quite heat stable. The LC system with a UV detection at 210 nm consists of a separation on a Zorbax TMS column and isocratic elution with water and ACN as a mobile phase. The alliin contents of raw and fried garlic flake under $140{\sim}150^{\circ}C$, $160{\sim}170^{\circ}C$ and $180{\sim}185^{\circ}C$ were 18.10 mg/mL, 14.0 mg/mL, 11.6 mg/mL and 11.1 mg/mL, respectively. The decrement of alliin content under different temperature was a small quantity hence, we confirmed that the increasing manufacturing temperature was not affected by the alliin content. Examining for the particle structure of fried garlic flakes by a polarization microscope, the color of the sample treated at $160{\sim}170^{\circ}C$ was pure yellow. Furder, the fiber shaped particle, which has an effect on the tough texture, almost did not appear compared to the different temperature conditions. Finally, the sensory test for the preference of fried garlic flake under different conditions was carried out and the scores for various sensory characteristics were surveyed. According to the physicochemical measurements and sensory evaluation, we confirmed that the optimum manufacturing condition of fried garlic flake was 1.5 mm thick at a temperature of $160{\sim}170^{\circ}C$.

Study on Density Discontinuous Layers of the Kunsan Basin in the Yellow Sea Using Satellite Altimetry Gravity Data (인공위성 해면고도계 중력자료를 이용한 황해 군산분지의 밀도 불연속면에 대한 연구)

  • Kim, Kyong-O;Oh, Jae-Ho
    • Economic and Environmental Geology
    • /
    • v.40 no.6
    • /
    • pp.751-759
    • /
    • 2007
  • To better understand the subsurface geological structure of the Kunsan Basin in the Yellow Sea, the mean depths of the density discontinuous layers (DDLs) of the Kunsan Basin were calculated by power spectrum analysis using satellite altimetry gravity data. The calculated mean depths of DDLs were -1.1km, -3.4km, -9.1km and -31.0km. The mean depth of -1.1km DDL was interpreted as regional unconformity shown in about 1 second in two way travel time (TWTT) in the seismic reflection profiles, and the mean depth of -3.4km DDL was also interpreted as top of the acoustic basement in the seismic reflection profiles. Comparing with well data, seismic reflection profiles and regional geology in the study area, the mean depth of -9.1km DDL was interpreted as top of the igneous origin basement. This means that the acoustic basement of the study area is composed mainly of sediments which are disregarded in previous study. The mean depth of -31.0km DDL was interpreted as the Moho discontinuity because this mean depth is similar to one of the normal continental crust thickness. The detection of top of the igneous origin basement suggests that oil gas potential analysis in Kunsan Basin needs to be extended to the deeper part of sediments (acoustic basement).

Acoustic Emission Monitoring of Incipient Failure in Journal Bearing Part II : Intervention of Foreign Particles in Lubrication (음향방출을 이용한 저어널 베어링의 조기파손감지(II) - 윤활유 이물질 혼입의 영향 및 감시 -)

  • Yoon, Dong-Jin;Kwon, Oh-Yang;Jung, Min-Hwa;Kim, Kyung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.122-131
    • /
    • 1994
  • Journal bearings in the rotating machineries are vulnerable to the contamination or the insufficient supply of lubricating oil, which is likely to be the cause of unexpected shutdown or malfunction of these systems. Various destructive and nondestructive testing methods had been used for the reduction of maintenance cost and the operational safety problems due to the accidents related to bearing damages. In this experimental approach, acoustic emission monitoring is employed to the detection of incipient failure caused by intervention of foreign particles most probable in the journal bearing systems. Experimental schedules for the intervention of foreign particles was composed to be more quantitative and systematic than last study in consideration of minimum oil film thickness and particle size. The experiment was conducted under such designed conditions as inserting alumina particles to the lubrication layer in the simulated journal bearing system. Several parameters such as AE rms level, waveform, AE energy distribution and other AE event parameters are used for analysis and characterization of damage source. The results showed that the history of damage was well correlated with the changes of AE rms level and the type of damage source signal can be verified using other informations such as waveform, distributions of AE parameters etc.

  • PDF