• 제목/요약/키워드: Offset Wrist

검색결과 14건 처리시간 0.02초

Offset Wrist를 갖는 6자유도 협동로봇의 역기구학 해석 (Inverse Kinematic Analysis of a 6-DOF Collaborative Robot with Offset Wrist)

  • 김기성;김한성
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.953-959
    • /
    • 2021
  • In this paper, the numerical inverse kinematics analysis is presented for a collaborative robot with an offset wrist. Robot manipulators with offset wrist are widely used in industrial applications, due to many advantages over those with wrist center and those with three parallel axes such as simple mechanical design, light weight, and so on. There may not exist a closed-form solution for a robot manipulator with offset wrist. A simple numerical method is applied to solve the inverse kinematics with offset wrist. Singularity is analyzed using Jacobian matrix and the numerical inverse kinematics algorithm is implemented on the real-time controller.

만성 편마비 환자의 손목 운동 시 근수축 특성 (Characteristics of Muscle Contraction During the Wrist Movement in Chronic Hemiplegic Stroke Patients)

  • 태기식;김사엽;송성재;이지용;이영희;김영호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.246-249
    • /
    • 2004
  • The purpose of this study was to investigate the characteristics between EMG timing of muscle contraction and motor impairment in chronic hemiplegic stroke patients. Delay time and co-contraction of 4 patients who had stroke less than 3 years were measured during isometric wrist flexion and extension along the 3 seconds beep signal. Onset and offset of muscle contraction were significantly delayed on the more affected sides than control sides. Offset was significantly delayed than the onset on the affected sides in wrist flexion. Also, recruitment of antagonist was larger than agonist on the affected sides. Co-contraction ratio on the affected side was significantly smaller than control sides in wrist flexion. In affected sides, Fugl-Meyer motor assessment(FMA) shows the correlation of onset delay in wrist flexion and extension. However, co-contraction ratio correlated with FMA in wrist flexion. EMG assessment is likely to be useful outcome measure and provide insights into mechanism for motor recovery in stroke patients.

  • PDF

Estimation of Motor Recovery using Characteristics of EMG during Isometric Muscle Contraction in Hemiparetic Wrist

  • Tae, Ki-Sik;Song, Sung-Jae;Kim, Young-Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.8-16
    • /
    • 2008
  • The aim of this study was to evaluate the motor recovery in 4 chronic hemiparetic patients with Fugl-Meyer (FM) and EMG characteristics before and after the training program. The training was performed at 1hr/day, 5days/week during 6 weeks in 4 chronic stroke patients. Electromyographic activities of the affected hand were recorded during isometric wrist flexion/ extension movements. In all patients, FM was significantly improved after the 6-week training. Onset/offset delay of muscle contraction significantly decreased in the affected wrist after the training. The co-contraction ratio of flexor/extensor muscles decreased significantly. Also, onset/offset delay of muscle contraction and co-contraction ratio correlates significantly with upper limb motor impairment and motor recovery. This EMG technique allows an objective evaluation of changes in muscle activity in post-stroke patients, providing easily measurable, quantitative indices of muscle characteristics.

손목오프셋을 갖는 6축 로봇을 위한 효과적인 역기구학 해 방법 (An Efficient Inverse Kinematics Solution Method for the 6 Axes Robot with Offest Wrist)

  • 범진환;임생기;손명현
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1421-1429
    • /
    • 1994
  • An algorithm is developed for solving the inverse kinematic problem of a 6-degree-of-freedom robot with a wrist offset for which the closed form inverse solutions are not obtainable, but knowledge of one joint variable allows closed form solutions of the remaining joint variables. The algorithm does not require Forward Kinematics nor Jacobian but uses the implicit kinematic relationships between joint variables and the given hand position. An iterative back substitution method is used to solve the inversion and the optimal conditions of the convergence are incoporated. An example is given to illustrate the concepts, the solution procedure and its convergency.

An Analysis of Inverse Kinematics and Singular Configuration for Six Axes Robot with Wrist Offset (ICEIC'04)

  • Lee YoungDae;Cho KumBae
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.263-268
    • /
    • 2004
  • The inverse kinematics problem is to find a set of joint variable values that will place the end effector of a robot manipulator into a given pose. Pieper has shown that a sufficient condition for a manipulator to have a closed form solution is that three adjacent joint axes intersects, hence the six axes robot with spherical wrist allows closed form solution. But many industrial robots have a non-spherical wrist to provide a stronger wrist configuration so that they can handle heavy payloads. Also, the use of a non-spherical wrist can result in a cheap and simple wrist arrangement than when all three axes intersect at a common point. In these cases, closed form solutions cannot be found. Therefore numerical technique must be used to solve the inverse kinematics equations. This paper proposes a new algorithm that can be used for finding inverse kinematics solution of the six axes robot with non-spherical wrist. Computer simulations are provided to prove the usefulness of our method.

  • PDF

초기 편마비 환자에서 손목 근수축 개시 및 종료의 특성: 중앙주파수 분석 (Characteristics of Initiation and Termination of Muscle Contraction in Early Hemiparetic Wrists: Analysis of Median Frequency)

  • 정이정;조상현;권오윤;이영희
    • 한국전문물리치료학회지
    • /
    • 제13권1호
    • /
    • pp.38-46
    • /
    • 2006
  • The purposes of this study were to investigate the median frequency (MDF) between initiation and termination of muscle contraction through surface electromyographic (sEMG) analysis and to propose the basis of clinical treatment for movement problems in early hemiparetic upper limbs. Thirteen patients who had stroke with onset less than 3 months prior to the study and seven control subjects participated in the study. The median frequency in initiation and termination of muscle contraction was recorded from wrist flexor and extensor muscles using the sEMG, with 3 second beeper signals, during maximal isometric wrist flexion and extension. Flexion and extension must be done as quickly and forcefully as possible. The results of the study were as follows: 1. The MDF of the onset and offset sections were significantly lower on the paretic than the nonparetic and control sides. 2. The MDF of the offset section significantly decreased on the paretic and nonparetic sides. Consequently, this study showed that the lowering of the MDF was due to the hemiparetic wrist motor impairment and muscle weakness. These results are also related to Fugl-Meyer motor assessment (FMA) scores in hemiparetic upper limbs. This study also suggests that since muscle weakness of early stroke patients affects the functional decrease of upper limbs, further studies must focus on the treatment to improve muscle agility and muscle fiber recruitment efficiency that can induce the functional recovery correlated to motor control.

  • PDF

뇌손상 후 상지 운동기능 회복 평가: 임상적 평가 및 운동반응 근전도 분석 (Evaluation of Upper-Limb Motor Recovery after Brain Injury: The Clinical Assessment and Electromyographic Analysis)

  • 김영호;태기식;송성재
    • 한국전문물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.91-99
    • /
    • 2005
  • We assessed whether the use of a symmetrical upper limb motion trainer in daily repetitive training for a 6-week period reduced spasticity and improved motor function in three chronic hemiparetic patients. Upper limb motor impairment and disability were measured by the Fugl-Meyer Assessment (FMA), Modified Ashworth Scale (MAS) and Manual Muscle Test (MMT), respectively. The electromyography (EMG) of the affected hand was recorded during isometric wrist flexion and extension. In all patients, FMA and MMT scores were significantly improved after the 6-week training. However, MAS scores of the affected wrist spasticity did not change considerably. Onset and Offset delays in muscle contraction significantly decreased in the affected wrist. The co-contraction ratio of flexor and extensor muscles significantly increased after the 6-week training. Onset and offset delays of the muscle contraction and co-contraction ratio correlated significantly with the patients' FMA. This study showed that repetitive, symmetric movement training can improve upper limb motor functions and abilities in chronic hemiparetic patients. Also, the EMG assessment of motor response is likely to provide insights into mechanisms and treatment strategies for motor recovery in chronic hemiparetic patients.

  • PDF

Development of Robotic Tools for Chemical Coupler Assembly

  • Jeong, Sung-Hun;Kim, Gi-Seong;Park, Shi-Baek;Kim, Han-Sung
    • 한국산업융합학회 논문집
    • /
    • 제25권6_1호
    • /
    • pp.953-959
    • /
    • 2022
  • In this paper, the design result of robotic tools and the development of robot control system for chemical coupler assembly are presented. This research aims to eliminate the risk of chemicals exposed to human operators by developing the robotic tools and robot automation system for chemical tank lorry unloading that were done manually. Due to tight tolerance between couplers, even small pose error may result in very large internal force. In order to resolve the problem, the 6-axis compliance device is employed, which can provide not only enough compliance between couplers but also F/T sensing. The 6-axis compliance device having large force and moment capacity is designed. A simple linear gripper with rack-and-pinion is designed to grasp two sizes of couplers. The proposed robot automation system consists of 6-DOF collaborative robot with offset wrist, 6-axis compliance device with F/T sensing, linear gripper, and two robot visions.

Feasibility of a New Desktop Motion Analysis System with a Video Game Console for Assessing Various Three-Dimensional Wrist Motions

  • Kim, Kwang Gi;Park, Chan Soo;Jeon, Suk Ha;Jung, Eui Yub;Ha, Jiyun;Lee, Sanglim
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.468-478
    • /
    • 2018
  • Background: The restriction of wrist motion results in limited hand function, and the evaluation of the range of wrist motion is related to the evaluation of wrist function. To analyze and compare the wrist motion during four selected tasks, we developed a new desktop motion analysis system using the motion controller for a home video game console. Methods: Eighteen healthy, right-handed subjects performed 15 trials of selective tasks (dart throwing, hammering, circumduction, and winding thread on a reel) with both wrists. The signals of light-emitting diode markers attached to the hand and forearm were detected by the optic receptor in the motion controller. We compared the results between both wrists and between motions with similar motion paths. Results: The parameters (range of motion, offset, coupling, and orientations of the oblique plane) for wrist motion were not significantly different between both wrists, except for radioulnar deviation for hammering and the orientation for thread winding. In each wrist, the ranges for hammering were larger than those for dart throwing. The offsets and the orientations of the oblique plane were not significantly different between circumduction and thread winding. Conclusions: The results for the parameters of dart throwing, hammering, and circumduction of our motion analysis system using the motion controller were considerably similar to those of the previous studies with three-dimensional reconstruction with computed tomography, electrogoniometer, and motion capture system. Therefore, our system may be a cost-effective and simple method for wrist motion analysis.

근전도 트리거 손목 재활 훈련 시스템 개발 (Electromyography Triggered Training System for Wrist Rehabilitation)

  • 김영훈;리두이콴;지영준;안경관;황창호
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.148-155
    • /
    • 2013
  • This study is about the development of the wrist rehabilitation system for the patient who has limited capability of movement after stroke. Electromyography triggered training system (ETTS) can play the role between complete passive training and patient activating training system. Surface EMG was measured on pronator teres muscle and biceps brachii muscle for wrist pronation and supination. Our system detects whether the subject makes muscular effort for pronation or supination or nothing in every 50 ms. When the effort level exceeds the preset percentage of maximal voluntary contraction, the motor rotates according to the direction of the intention of the subject. EMG triggers the motor rotation for the wrist rehabilitation training until the preset angle. To evaluate its performance, the maximum voluntary contraction level was measured for 4 subjects at first. With the audio-visual instruction to rotate the wrist (pronation or supination) the subjects made effort to follow the instruction. After calculating root mean square (RMS) for 50 ms, the controller determines whether there was muscular effort to rotate while holding the motor. When there was an effort to rotate, the controller rotates the motor 0.8 degree. By comparing the RMS values from two channels of EMG, the controller determines the rotational direction. The onset delay is $0.76{\pm}0.24$ s and offset delay is $0.65{\pm}0.22$ s for pronation. For supination the onset delay is $1.24{\pm}0.41$ s and offset delay is $0.77{\pm}0.22$ s. The system responded fast enough to be used for rehabilitation training. The controller perceived the direction of rotation 100% correctly for the pronation and 97.5% correctly for supination. ETTS was developed and the fundamental functions were validated for normal subjects. The clinical validation should be done with patients for real world application. With ETTS, the subjects can train voluntarily over the limitation of the range of motion which increases the effectiveness of the rehabilitation training.