• Title/Summary/Keyword: Office Tower

Search Result 53, Processing Time 0.035 seconds

Structural Design of Nakanoshima Festival Tower

  • Okada, Ken;Yoshida, Satoshi
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.173-183
    • /
    • 2014
  • Nakanoshima Festival Tower is a 200 m high-rise complex building which contains a renewed 2700-seat capacity concert hall known as "Festival Hall" and offices including headquarter of a news company. In order to build up an office tower on the hall which requires large open space, a giant truss system is employed. The giant trusses being composed of mega-trusses and belt-trusses support all the building weight above them and transfer the load to the outside of the hall. The building also requires high seismic resistance performance for a news company. Application of mid-story seismic isolation enables the building to satisfy high-level seismic resistance criteria.

A study on the mechanical strength system and supporting method of insulator strings for KEPCO 765kV transmission lines (한전 765 kV 송전선로 애자장치 강도계열 및 지지방식에 관한 검토)

  • Han, Yup;Park, K.H.;Yoon, S.H.;Seo, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1920-1922
    • /
    • 1996
  • After determining the type and string condition of conductor of 765kV transmission lines, we studied the mechanical strength system of insulator strings to support conductors and insulate conductors from towers. In this paper, for the insulator strings which will be used in 765kV transmission lines, we're going to optimally determine the mechanical strength system and supporting method in the consideration of the reliability, economics and the survey data of T/L routes, and also suggest the calculation method to stipulate for the application limits of suspension and strain insulator strings according to the loadspan and height difference of tower.

  • PDF

Structural Design of Nakanoshima Festival Tower West that Achieved High-Grade Seismic Performance

  • Kumano, Takehito;Yoshida, Satoshi;Saburi, Kazuhiro
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.217-226
    • /
    • 2017
  • This paper summarizes the structural concept and design of the "Nakanoshima Festival Tower West" in Osaka, Japan, which is 200m high and has a super-high damping system. Its superstructure is mainly composed of a central core and outer tube frames. It has a bottom truss structure at the boundary between the low-rise and mid-rise sections of the building, where the column arrangement is changed. Besides, the high-rise section of the building has a neck truss structure. These truss structures smoothly transfer the axial forces of the columns and reduce the flexural deformations induced by horizontal loads. Oil dampers with extremely high damping capacity are installed in the rigid walls named the "Big Wall Frames" of the low-rise section. Moreover, many braces and damping devices are well arranged in the center core of each story. The damping effects of these devices ensure that all structural members are remain within the elastic range and that story drifts are within 1/150 in large earthquakes. This super-high damping structure in the low-rise section is named the "Damping Layer". The whole structural system is named the "Super Damping Structure". The whole structural systems enhance the building's safety, comfort and Business Continuity Planning (BCP) under large earthquakes.

A study on the design of conductor stringing for KEPCO 765kV Transmission Lines (한전 765 kV 송전선로 전선가선설계에 관한 검토)

  • Park, K.H.;Kim, Y.W.;Won, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1330-1331
    • /
    • 1995
  • This paper deals with the design of conductor stringing of KEPCO 765kV transmission line. The main subject in the design of conductor stringing is the determination on what the stringing tension is. According to the stringing tension, the weight and height of towers and the strength necessary for conductor, hardware, insulator vary, and the construction cost and the reliability of tower are affected largely. Therefore, in order to determine the optimum condition for stringing conductors, We appraised various items : estimation of economic comparision, strength appraisal of conductor, hardware, insulator, etc. After studying these entirely, we present the condition of condutor stringing for KEPCO 765kV transmission line.

  • PDF

Detemination of Tower Skeleton Diagram for KEPCO 765kV Transmission Lines (765kv 송전용 철탑 Skeleton Diagram 결정)

  • Park, K.H.;Kim, Y.W.;Won, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1804-1806
    • /
    • 1997
  • Route conditions, applied voltage and the condition of stringing conductors should be considered in determining standard types and skeleton diagrams of towers. In skeleton diagrams the necessary number of insulators and the air clearance have been decided by the results of studies on insulation coordination. Galloping, sleet-jumping, sag characteristics and the possibility of closeness of conductors should be considered according to the condition of stringing conductor and the span. After reviewing those factors, it is necessary to determine the minimum vertical and horizontal distance for the safety of transmission lines under any circumstances. Also it should be economical.

  • PDF

MOVEMENT CONTROL OF HIGH-RISE BUILDINGS DURING CONSTRUCTION

  • Taehun Ha;Sungho Lee;Bohwan Oh
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.46-51
    • /
    • 2011
  • High-rise buildings are widely being constructed in the Middle-East, South-East, and East Asia. These buildings are usually willing to stand for the landmark of the region and, therefore, exhibit some extraordinary features such as super-tall height, elevation set-backs, overhangs, or free-form exterior surface, all of which makes the construction difficult, complex, and even unsafe at some construction stages. In addition to the elaborately planned construction sequence, prediction and monitoring of building's movement during construction and after completion are required for precise and safe construction. This is often called the Building Movement Control during construction. This study describes Building Movement Control of the KLCC Tower, a 58-story office building currently being built right next to the famous PETRONAS Twin Towers. The main items of the Building Movement Control for the KLCC Tower are axial shortening and verticality. Preliminary prediction of these items are already carried out by the structural design team but more accurate prediction based on construction stage analysis and combined with time-dependent material testing, field monitoring, and site survey is done by the main contractor. As of September 2010, the Tower is under construction at level 30, where the plan abruptly changes from rectangle to triangle. Findings and troubleshooting until the current construction stage are explained in detail and implementations are suggested for future applications.

  • PDF

Sustainable Design and Its Cost: Case Study of Nanning China Resources Tower

  • Lai, Stephen Y.F.
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.4
    • /
    • pp.323-326
    • /
    • 2017
  • Sustainability is becoming more and more important in our everyday lives. Thus, it is apparent that more sustainable initiatives are incorporated in a building design concept to reduce operation costs and environmental impacts. However, will the construction cost go up if the building is going green - especially if it is a tall building? This is the question on everyone's mind. In the following paragraphs, we will look into a case study of a skyscraper in Nanning, China. That 411-metre skyscraper, Nanning China Resources Centre East Office Tower, is currently under construction. Designed to LEED-CS Gold standards, the building has adopted a number of sustainable design elements and operation practice, which indeed only accounts for a small percentage of the total construction cost.

Structural Design of High-Rise Concrete Condominium with Wall Dampers for Vibration Control

  • Tsushi, Takumi;Ogura, Fumitaka;Uekusa, Masahiro;Kake, Satoshi;Tsuchihashi, Toru;Yasuda, Masaharu;Furuta, Takuya
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.201-209
    • /
    • 2019
  • This paper presents a structural design of the "(Tentative Name) Toranomon Hills Residential Tower" which is currently under construction in Tokyo. The building is a reinforced concrete high-rise residential complex building with 54 stories above ground, 4 basement levels, and a building height of about 220 m. It is a requirement to provide the highest grade of residence in Japan, and in terms of the structural design, it is required to provide wide and comfortable spaces with high seismic performance. These requirements are satisfied by providing a total of 774 vibration control walls of two types. Also, to further improve the structural performance, steel fibers at the rate of 1.0vol% are provided in the ultra-high strength concrete used in the column members.

Performance for Geothermal Heating & Cooling System by Heatpump in Office Building (사무용건물에서 지열히트펌프냉난방시스템의 운전성능 평가)

  • An, Hyung-Jun;Baek, Sung-Kwon;Cho, Chung-Sik;Sohn, Byung-Hu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.1
    • /
    • pp.23-29
    • /
    • 2007
  • For the perfomance test of geothermal system, a large pilot of capacity of 50RT is built and operated in office building. This system is planed hybrid system with cooling tower as asisstance heat sink. From October, 2004 to September, 2005, this system is operated andmonitored. As the result, COP of heating periods is about 3.46 and COP of cooling periods is about 4.1. Therefore, geothermal system is useful and suitable in Korea.

  • PDF

Safety Diagnosis & Rainforced Countermeasure in Steel Tower (해원철탑 안전진단과 보강대책방안)

  • Park, Won-Chul;Lee, Jae-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.819-821
    • /
    • 1997
  • 경제발전에 따른 국민 생활향상과 산업고도화에 의해 전력은 계속하여 수요가 증가하고 대용량화 되어가고 있으며 그와 함께 지속적이고 안정된 전력공급은 그 중요성이 더욱 대두된다. 서남해안 도서지역은 전력수요가 96년대에는 13.5%증가하였으며 전선로의 설비는 가공해월청탑과 해저케이블, 공급방식은 수지상식의 취약선로이다. 폭풍이나 태풍에 의해 해월청탑의 도괴된 사례가 발생하여 가공송전선을 설계 기준중 기준풍속을 지역별로 구분, 상향조정(87.6)되었으며 기존 해월청탑 설비에 대한 안정성 검토의 필요성이 대두되었다. 태풍 또는 폭퐁에 의한 해월청탑 지지물의 도괴, 또는 파손 등의 피해를 방지기존철탑 및 기초안전도를 검토하고 보강필요시 우리 실정에 맞는 경제적이고 안정된 보강방범 및 공법을 연구 개발하여 이에 의한 설계 및 시공기준을 수립하고자 한다.

  • PDF