• 제목/요약/키워드: Office Lighting

검색결과 147건 처리시간 0.025초

Interior Partitioned Layout and Daylighting Energy Performance in Office Buildings

  • Kim, Gon
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.31-40
    • /
    • 1999
  • In this age of "Information", many people consider it a deterrent to information flow to provide a hierarchy with private rooms in a modern office layout. There are others, however, who insist that visual and acoustical privacy are more important than any other design factor in achieving higher productivity. The debate may never end, but the partitioned open plan, which is a new form of the vast open plan, has merits of each concept - open and closed layout. Consequently, office design has dramatically shifted to partitioned open planning, with shorter, temporary walls or partitions, originally intended for increasing privacy and diminishing hierarchy, yet still keeping flexibility in spatial organization. The introduction of low-level partitioned spaces in an office layout, however, produces a complicated lighting design problem. Obviously, accurately predicted daylighting performance data are needed not only for daylighting design but for artificial lighting system design. Scale models of 12 sets of unit partitioned spaces are constructed and extensive scale model measurements of both daylight and reflected sunlight have been performed within an artificial sky simulator. The prototype-building interior is modeled with different partition configurations, each of which is modeled using the different envelope geometry and exterior configurations, and then the variations in interior light levels are estimated. The result indicates that partitioned spaces employed in an open plan of modern offices still offer a large potential for daylighting and energy saving as well. Much of the savings may derive from the cumulative effect of reflected sunlight. Optimal design for building envelope geometry and exterior configuration promises additional savings.

  • PDF

중규모 사무공간에서 조명에너지 성능평가를 위한 노모그래프 개발에 관한 연구 (Development of Nomographs for the Evaluation of Lighting Energy Performance in a Semi-infinite Office Space)

  • 김한성;고동환;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.73-80
    • /
    • 2003
  • The purpose of this study was to analyze daylighting performance in a semi-infinite size office space for lighting energy conservation. DOE2.1E was used for simulations for the model space of $12\times12\times2.6m$. Nomographs were developed which could simulate work plane illuminance, glare index, energy consumption rate and energy reduction rate for daylighting design. Major results of simulations are as follows ; 1) When blinds facing south were installed, 43% of workplane illuminance diminished, but the flare index didn't exceed the recommended max-glare value. 2) In a semi-infinite office space facing south. energy consumption rate in the case space of 500 lux workplane illuminance is larger then case space of 300 lux workplane illuminance. Therefore, energy reduction rate is increased when the semi-infinite office faces south and naintains 300 lux workplane illuminance level.

소규모 사무공간의 조명에너지 절감율 평가에 관한 연구 (Evaluation of Lighting Energy Saving Rate in a Small Office Space)

  • 김한용;윤경;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.50-58
    • /
    • 2012
  • The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m.

사무소 건축의 공공화장실 실내설계 기법에 관한 연구 (A Study on the Interior Design Method of Public-Toilet in Office Building)

  • 김정범;김은중
    • 한국실내디자인학회논문집
    • /
    • 제16호
    • /
    • pp.16-21
    • /
    • 1998
  • This study aims at developing the interior design method of Public Toilet in office building. There needs new concepts in Public Toilet where we felt dirty smelling and dismal in the past. And the behavior in the Public Toilet become various such as combing the hair making-up changing the clothes rinsing out mouth and so on. Nowadays The Public Toilet of office building shows indirectly the hierarchy and the management philosophy of its enterprise, This study treats with the design items such as unit space zoning plan lighting plan and air-conditioning plan and construction method of Public-Toilet in office building. As a result of this study the interior design methods of Public Toilet must reflect use of fitting material lighting plan user's needs and functional divide.(Powder Zone and Physiology Zone) These result will become basic data of future interior design in Public Toilet.

  • PDF

Office Environment and Musculoskeletal Complaints of Office Workers

  • Park, Myoung Hwan;Lee, Sangbok;Jeong, Byung Yong
    • 대한인간공학회지
    • /
    • 제34권6호
    • /
    • pp.609-622
    • /
    • 2015
  • Objective: This study aims to investigate the correlation between office and work environment satisfaction levels and workers' musculoskeletal symptoms by conducting surveys asking office workers to state their musculoskeletal symptoms and office and work environment satisfaction levels. Background: The increased number of office workers and their indoor work hours using computers have led to new understandings of the importance of office environment including its temperature, humidity, noise levels, lighting and quality of air, and work environment including monitor arrangement, space arrangement and the functions of desks and chairs. Method: Specific details on office work, office environment satisfaction levels, work environment satisfaction levels, musculoskeletal symptoms, absence from work and treatment due to musculoskeletal related symptoms were analyzed based on the survey answers given by 397 office workers who were the subjects of this research. Results: Office workers showed different characteristics of musculoskeletal symptoms depending on their gender, age, work experience, office hours, break time and time spent on computers. Also, differences in symptoms were found for workers'with different satisfaction levels for office environment (temperature, humidity, noise levels, quality of air, lighting) and work environment (location of monitors, area and display of office space, chairs and desks). ANOVA shows the differences between groups of subjects classified by the experience of work-absences and treatments or pain complaints. Conclusion and Application: Relationship between workers' satisfaction levels with the office and work environment and their musculoskeletal symptoms is expected to be served as essential data for systematic management of the workplace.

스마트폰을 이용한 그린 LED 감성조명 시스템 (A Green LED Sensitivity Lighting System Using Smart Phone)

  • 조면균
    • 대한임베디드공학회논문지
    • /
    • 제7권2호
    • /
    • pp.103-111
    • /
    • 2012
  • This paper introduces a novel concept of 'A Green LED Sensitivity Lighting System' which can automatically estimate QoS(quality of service) and emotional requirements of user using smart phone. And it can intelligently control ambient illumination lamp to conserve electric energy and to satisfy human sensitivity. The proposed system has 4 control modes; emotional lighting, smart lighting, green lighting and realistic lighting modes in order to comfort man's emotion, to maximize work efficiency, to save energy consumption and to make the entertainment more fun, respectively. When we choose green lighting mode for indoor office situations, an elaborate simulation shows that the proposed system with home network can reduce the energy by 50% compared to conventional light control system with a fixed time-based switching.

주광량의 변화에 따른 LED조명 제어를 통한 에너지 절감량 분석에 관한 연구 (A Study on Energy Savings Analysis by Controling LED Lighting according to the Change of the Amount of Daylight)

  • 함원태;채수용;한수빈;김흥근;정학근
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.522-528
    • /
    • 2012
  • Currently, the energy consumption of electric lighting in an office building is accounted for more than 30% of the total energy consumption. In order to reduce the energy consumed by the indoor lighting, the daylight as a natural energy resource can play an important role in energy savings. The daylight can have positive impacts on improvement of work efficiency and productivity, and also make people feel more psychologically stable. Moreover, by using the daylight, we can definitely reduce the energy consumption in office buildings. Thus, the purpose of this study is to determine the LED dimming ratio depending on the ratio by calculating the amount of artificial illumination required according to the change of daylight by using the light simulation software that can quantify and visualize the performance of daylight. As a result, the energy savings could be obtained up to 30%.

  • PDF

창호의 투과율과 블라인드 슬랫각도에 따른 빛환경 및 에너지성능 비교 연구 (Comparative Studies on Lighting Environment and Energy Performance depending on the Transmittance of Window and Slat Angle of Blind)

  • 심세라;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.256-263
    • /
    • 2011
  • Recently, curtain wall structure is constructed according to increasing high rise building. Glass is usually used in opening of curtain wall structure and window area ratio is finally increased. Excessive Daylighting and solar radiation by large window area ratio cause discomfort glare and add to cooling load in the case of office that is heavy on lighting and cooling. Therefore, this study suggests to use low transmittance window for solve those problems. Indoor lighting environment and building energy performance were analyzed by increasing transmittance from 10% to 90% and comparing fixed venetian blind. Consequently, the range of transmittance that is possible to daylighting and prevent discomfort glare. Secondary energy consumption is efficient in the case that transmittance is the range of from 20% to 50%, primary energy consumption is nice on from 20% to 40%. If those result put together, the range of window transmittance from 30% to 50% is proper in the office in lighting environment and energy consumption aspects.

  • PDF

인텔리전트 빌딩의 공간특성을 고려한 배광결정과 형광등기구 설계 (Decision of the Luminous Intensity Distribution and Design of fluorescent Luminaire Based on Space Features of the Intelligent Building)

  • 이정욱;김홍범;한종성;김훈
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.10-17
    • /
    • 2001
  • 공간의 효율적 조명시스템의 설계를 위해서는 그 공간의 물리적 조건들과 작업의 내용 등을 고려하여 표준적인 상황을 규정하고, 그 상황에서 가장 유용한 조명설계를 찾아내어 표준화해야 한다. 특히, 인텔리전트 빌딩에서는 OA도입으로 인한 W 작업환경, 취업인구의 고령화 등의 공간특성을 고려한 조명계획이 요구되며 이러한 조명계획을 구현할 수 있는 조명기구를 제작할 필요가 있다. 따라서 이 연구에서는 국내 인텔리전트 빌딩의 주요 공간별 크기와 형태 및 특성을 조사하여 표준공간을 선정했고, 이를 반사판설계에 반영하여 3 가지 형태의 형광 등기구를 설계, 분석하였다.

  • PDF