• 제목/요약/키워드: Office Buildings

검색결과 619건 처리시간 0.03초

일제강점기 관찰부 이전(移轉) 후 관련건축물의 변화에 관한 연구 -수원과 충주를 중심으로- (Changes of Gyeonggi and Chungbuk Provincial Office Buildings after Relocation during Japanese Colonial Period -focusing on Suwon and Chungju-)

  • 최지해;한동수
    • 건축역사연구
    • /
    • 제30권4호
    • /
    • pp.7-16
    • /
    • 2021
  • This study examines changes and features of provincial office buildings in Suwon and Chungju after relocation during Japanese occupation. Gyeonggi and Chungbuk provincial offices(Gwanchalbu) were relocated by Japan. Gyeonggi Provincial Office in Suwon used HwaseongHaenggung buildings and moved to Seoul in 1910. After relocation, most of HwaseongHaenggung buildings used for Suwon Governmental hospital(JaHye Uiwon). Suwongun Office, Suwon public elementary school, Japanese Military and Suwon Police station also used HwaseongHaenggung buildings with the Hospital. At first, Japan remodeled local government buildings for their use. Most of HwaseongHaenggung buildings had been destroyed to build new buildings since 1920s. Chungbuk Provincial office in Chungju used DongHeon building which is Chungju local government building and relocated to Cheongju in 1908. DongHeon building changed to Chungju county office after relocation. This building was renovated. Chungju county office moved to other site, this building was used for Chungju county conference room. During Japanese colonial period, Suwon local government buildings were destroyed and replaced with new Japanese style buildings. Chungju local government buildings were also renovated or destroyed.

고층 사무소건축의 화재안전에 관한 건축계획적 연구 (A Study on the Fire Safety of High-rise Office Buildings in Respect of Architectural Design)

  • 이강훈
    • 한국화재소방학회논문지
    • /
    • 제8권2호
    • /
    • pp.3-15
    • /
    • 1994
  • The purpose of this paper is to present refernce data to be considered in designing for the fire safety of high-rise office buildings. This paper deals with the characteristics of high-rise office buildings in the fire safety aspects, the basic principles for the fire safety of high-rise office building design, and this study is focused particularly on the location of the escape route of core plan for fire safety in high-rise office buildings.

  • PDF

Verification of diaphragm seismic design factors for precast concrete office buildings

  • Zhang, Dichuan;Fleischman, Robert B.;Lee, Deuckhang
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.13-27
    • /
    • 2021
  • A new seismic design methodology has been developed for precast concrete diaphragms. Seismic design factors were used to be applied on top of diaphragm seismic design forces in the current code. These factors, established through extensive parametric studies, align diaphragm design strengths with different seismic performance targets. A simplified evaluation structure with a single-bay plan was used in the parametric studies. This simplified evaluation structure is reasonable and cost-effective as it can comprehensively cover structural geometries and design parameters. However, further verification and investigation are required to apply these design factors to prototype structures with realistic layouts. This paper presents diaphragm design of several precast concrete office buildings using the new design methodology. The applicability of the design factor to the office building was evaluated and verified through nonlinear time history analyses. The seismic behavior and performance of the diaphragm were investigated for the precast concrete office buildings. It was found that the design factor established for the new design methodology is applicable to the realistic precast concrete office buildings.

건물(建物) 최대수요전력(最大需要電力)의 효율적(效率的) 운용(運用) 방안(方案) (A Study on the Efficient peak Demand Control Method in Office Buildings)

  • 김세동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1088-1090
    • /
    • 1993
  • This paper shows efficient peak demand control method in office buildings. With a rapid growth of national economics and living standard, electrical energy consumption markedly increased. Expecially, it is increased electrical energy comsumption in the office buildings and thus an energy conservation through efficient use of electricity became more important. From the data of electric equipment capacity and electric power consumption for 96 buildings, current levels of demand factor and a growth trend of peak loads by office buildings were surveyed and analyzed. In addition the efficient peak demand control method in office buildings were studied.

  • PDF

업무용 빌딩 소재 사무실의 실내환기 평가 (Assessment of indoor ventilation in commercial office buildings)

  • 정지연;이광용;이병규
    • 한국산업보건학회지
    • /
    • 제18권2호
    • /
    • pp.115-121
    • /
    • 2008
  • In winter season, the survey was performed in three commercial office buildings in the metropolitan Seoul, Pusan, and Gwangju city. The purpose of the survey was to evaluate the effectiveness of ventilation for offices in commercial buildings. The data were compared to standard of applicable to the indoor ventilation in office. The results indicated that the most commercial office buildings used the air handing unit and fan coil unit as HVAC system, and the intake amount of fresh outdoor air were very inadequate to compared to the ASHRAE standard value of $0.57\;m^3/min/person$. Also the surveyed all commercial office building used the HVAC system as a meas of controlling temperature for office indoor air. Ultimately, these results presented that there were possibility of evoking indoor air quality problems by the insufficient ventilation.

계측데이터를 이용한 업무시설에서의 에너지용도별 사용량 추정방법 연구 (Estimation Method of Energy Consumption by End-Use in Office Buildings based on the Measurement Data)

  • 김성임;양인호;하수연;이수진;진혜선;서인애;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.165-176
    • /
    • 2020
  • The purpose of this study is to develop a estimation method of energy consumption by end-use in office buildings. For this, the current status of information on building energy use was investigated, and the domestic and foreign literature on the classification of energy use in non-residential buildings and the estimation method of energy use were reviewed. In addition, the characteristics of energy consumption by end-use were analyzed with measurement data of 48 office buildings in Seoul. As results, the annual and monthly estimation method of energy consumption by end-use in office buildings using public and measurement data was presented, and the applicability of the estimation method was examined by applying to sample office buildings.

건물에너지성능기준 강화 이후 국내공공기관 업무용 건축물의 디자인경향 (A Study on Design Tendencies in Office Buildings of Public Institutions after Reinforcement of the Building Energy Performance Criteria in Korea)

  • 이아영
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.139-149
    • /
    • 2011
  • This study focuses on design tendencies in office buildings of public institutions after tightening up Korea's building energy performance criteria. Important office design criteria and recommendations pay attention to the issues such as building orientation, greening buildings, building form, space and envelop by intensifying building energy performance related laws, government guidelines and evaluation systems. The design tendencies explored in this research are as follows. Office buildings mainly face south and have various types of indoor and roof green spaces not for ecological reasons but for the rest. Building depth becomes thinner and atria are inserted into office buildings to improve daylighting and natural ventilation. Building cores are located on north or west and east sides acting as buffer spaces to reduce heat loss and to block solar radiation. Office building envelop design includes various creative ideas to control or utilize solar energy as like three dimensional or double structured skin and window size variation to cope with the intensity of solar radiation. Further, solar energy generation systems are integrated with building component such as roofs, sun screens and windows. This study demonstrates that government's reinforcement of the building energy performance criteria drives the change in design methods and approach.

조선시대 울산군 부평역촌의 구성과 배치에 관한 연구 (A Study on the Configuration and Placement of Bupyeong-office town in Ulsan county During Chosun Dynasty)

  • 황대일
    • 건축역사연구
    • /
    • 제23권1호
    • /
    • pp.21-31
    • /
    • 2014
  • The paper analyzed the excavational data from Bupyeong-office in Ulsan county in Chosun Dynasty, examined the composition of the community estimated at station community, and studied the duration of the community by using the excavated relics. In addition, the paper compared the excavational data with documentary records, studied the location Bupyeong-office, and investigated the size of station community overall. Community compositions such as buildings, residential place, pits, stoves, hemp kilns, cremation tombs, and farming appliances were identified. When compared to excavated relics such as tiles, white porcelain jars, agrayish-blue-powdered celadons, and celadon porcelains from building, residance, and pits, the community existed during 14C~17C. The station location was on the west side to the quarters for Byongmajuldosa of the Left Gyeongsangdo at King's location according to the old maps and documentary records. It is widely expected that No, 201 foundation stone buildings at Pyungsan relic I was related to the station because there was a distinctions on the stone pillar waterway and high quality of location in the size(the front 9 sections ${\times}$ the side 1 section) and the community. According to the building's functions and duplication relations in the community, it is regarded that there were 33~40 ground buildings, 40~45 pitting buildings, storages or 15~30 other purpose buildings, and 5~7 public buildings around No, 210 building in Bupyeong-office town.

부하 형태에 따른 전력패턴 분석 (Analysis of Power Pattern According to Load Types)

  • 황미용;조승준;이순형;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.369-375
    • /
    • 2023
  • In this paper, we compared and analyzed the power load patterns of dormitory buildings and office buildings to use them as basic data (demand analysis and capacity design) for the design and operation of microgrids for multi-use facilities, and the following conclusions were got. During the daytime on regular weekdays, the power consumption load pattern of office buildings was relatively large at 264.0~332.3 kWh, and during the evening hours, the power consumption load pattern of dormitory buildings was relatively large at 233.0~258.3 kWh. In the case of vacation, during the daytime on weekdays, the power consumption load pattern of office buildings was relatively large at 279.1~407.4 kWh, and in the evening, the power consumption load pattern of dormitory buildings was relatively high at 280.1~394.1 kWh. During the daytime on regular weekends, the power consumption of dormitory-type buildings was relatively high at 133.5~201.6 kWh, and it was found that the power consumption of dormitory-type buildings appeared relatively high at 187.5~252.1 kWh. During a vacation in the daytime on weekends, the power consumption of dormitory-type buildings was found to be 186.5 kWh~ and 218.6 kWh. The increase in power consumption during a vacation (December-February) compared to normal (April-June) was thought to be due to an increase in electricity demand, and the reason for the higher power consumption in dormitory buildings during the vacation was due to reduced working hours in office buildings.

제주지역 공공업무시설의 장애물 없는 생활환경 실태조사 연구 (A Survey on the Barrier-Free Environment of Public Office Building in Jeju Area)

  • 성기창;박철민;김인배
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권4호
    • /
    • pp.29-36
    • /
    • 2016
  • Purpose: Considering the proportion of the population such as the elderly, pregnant women, infants companion and constantly increasing foreign tourists, there is a high need for implementing an environment without barriers. In terms of policy and institutional aspects, Jeju Special Self-Governing Province is striving to create an environment without barriers and to promote the safety and convenience of Vulnerable Pedestrians. But it is not enough to create a viable barrier-free environment. Methods: Method of this research is to analyze the general population status and installed facilities status for the disabled in Jeju. And analysis of policy research needs and level of barrier-free. By applying the barrier-free environment certification standards should conduct an assessment of the level of the current public office buildings in Jeju. It presents the environmental improvement of public office buildings for barrier-free environment. Result: Barrier-free environment status of the five public office buildings research surveyed all buildings have shown low levels of installed facilities for the disabled. In particular, it was analyzed that represents a very low level in the intermediate facilities and other facilities. The development of a specific installation manual for the facilities for the disabled is required to improve public office buildings. And barrier-free criteria need to reflect on the implementation of regulations. Implications: Through continuous research to analyze the barrier-free level and problems of public office buildings, it will be made to improve the comprehensive and reasonable alternative.