• Title/Summary/Keyword: Off-shore wind

Search Result 44, Processing Time 0.022 seconds

Long-term Scenarios for Development of Off-shore Wind Farms (중장기 해상풍력 단지개발 시나리오에 관한 연구)

  • Lee, Sang Hoon;Sung, Chang Kyung
    • Journal of Wind Energy
    • /
    • v.5 no.2
    • /
    • pp.45-50
    • /
    • 2014
  • Reviewing the capacity and timing of Southwest sea offshore wind farms, additional farms developing, and potential farms, we devised the long-term plan of domestic offshore wind farms development. In order to rank many wind farms, we determined evaluation indicators and weights of priority. We applied economic and preliminary factors such as wind grade, depth of water, distance from substations, farms scale, MOU signed, and feasibility studies. After deciding the ranking of wind farms by the scores, we planed domestic long-term scenarios of offshore wind farms development to meet national energy policy objectives.

Compensation of Unbalanced PCC Voltage in an Off-shore Wind Farm of PMSG Type Turbines (해상풍력단지에서의 PMSG 풍력발전기를 활용한 계통연계점 불평형 전원 보상)

  • Kang, Ja-Yoon;Han, Dae-Su;Suh, Yong-Sug;Jung, Byoung-Chang;Kim, Jeong-Joong;Park, Jong-Hyung;Choi, Young-Joon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • This paper proposes a control algorithm for permanent magnet synchronous generators with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage off-shore wind power system under unbalanced grid conditions. Specifically, the proposed control algorithm compensates for unbalanced grid voltage at the PCC (Point of Common Coupling) in a collector bus of an off-shore wind power system. This control algorithm has been formulated based on symmetrical components in positive and negative synchronous rotating reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power is described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of AC input current is injected into the PCC in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm enables the provision of balanced voltage at the PCC resulting in the high quality generated power from off-shore wind power systems under unbalanced network conditions.

The Physical Environments and Cochlodinium polykrikoides Bloom in the Sea near Naro-Do

  • Lee, Dong-Kyu;Kang, Yoon-Hyang
    • Ocean and Polar Research
    • /
    • v.25 no.3
    • /
    • pp.303-314
    • /
    • 2003
  • The initiation of Cochlodinium polykrikoides blooming in the South Sea of Korea occurs in the sea near Naro-Do in late August. In this paper, the relationships of this annual occurrence with the environmental conditions are presented. In early summer, the winds in the sea near Naro-Do are southwesterly and the upwelling occurs in the near-shore area. The favorable winds to the upwelling are relaxed in August and the downwelling favorable northeasterly winds set in around late August. The change of wind direction causes the onshore transport of warm-and-fresh off-shore water into the sea near Naro-Do and a front between near-shore water and off·shore water is formed. Along the front, downwelling occurs and the environmental conditions for the diatom become unfavorable. When the typhoon and storm bring well-mixed East China Sea water into the sea near Naro-Do in September, the conditions for the dinoflagellates become unfavorable and blooming of C. polykrikoides disappears.

Power Control of Small Wind Power System (소형 풍력발전시스템의 출력제어)

  • Kim, Chul-Ho;Lee, Hyun-Chae;Seo, Young-Taek;Cho, Hwan-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1066_1067
    • /
    • 2009
  • Wind power is one of most promising renewable energy. The output capacity of large wind turbine has been increased for off-shore application. Number of installation of small wind turbine also has been increased for the stand-alone and off-grid application of remote area and recently small wind turbine equipped with lamp on the pole is used for street lamp. Maximum wind energy must be extracted by wind turbine within rated wind speed. Power must be controlled to protect the system such as blade, generator, and power system above the rated wind speed. In this paper, small wind power system of 800W rating for battery charging is implemented and output power control by furling system is verified at wind tunnel test.

  • PDF

Ocean Response to Typhoon Rusa in the South Sea of Korea and in the East China Sea

  • Lee, Dong-Kyu;Niiler, Peter
    • Journal of the korean society of oceanography
    • /
    • v.38 no.2
    • /
    • pp.60-67
    • /
    • 2003
  • Typhoon Rusa passed over the East China Sea and crossed over the Korea Peninsula on August 31, 2002. The core of the typhoon passed directly over a data buoy mooring site at ($127^{\circ}45'E,\;34^{\circ}25'\;N$) and several ARGOS-tracked drifters capable of measuring salinity. Peak hourly mean wind speed reached 28 m/s at the mooring site and wind pattern in the East China Sea changed from southerly wind to northwesterly wind after the typhoon passage. Two or three days before the typhoon tile drifter displacement changed significantly and the region-wide circulation pattern changed from a northeastward current to a westward current one week after the typhoon had passed. The surface water in the East China Sea was cooled to about $4^{\circ}C$ under the typhoon core and a general cooling occurred in most of the East China Sea with the exception of the Chinese coast. The salinity as observed by the drifters in the East China Sea increased about 2 psu but the near-shore water along the Korean coast observed by the mooring was freshened about 3 psu. The freshening of near-shore water was caused by an intrusion of off-shore water rather than local freshening by typhoon precipitation.

Configuration and Operation characteristics of a Small stand-alone Wind Power Generation System (독립형 소형 풍력발전시스템 구성 및 운전특성)

  • Hwang, In-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.65-68
    • /
    • 2002
  • Most of the present demand in the world is met by fossil and nuclear power plants. A small part is met by renewable energy technologies. Among the renewable power sources, wind and solar energy have experienced a remarkably rapid growth in the past 10 years. Recently the utilization of wind power has been receiving close attention in this country, especially for the electrification of off-shore islands. The objective of this study is to demonstrate a small wind energy system as a stand-alone power source.

  • PDF

A Study on the Upwelling Phenomena of Anoxic Bottom Water (Blue Tide Phenomena) in the Coastal Areas (연안역에서의 저층 빈 산소수의 용승현상(청조현상)에 관한 연구)

  • 윤종성
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.291-300
    • /
    • 1998
  • Recently, upwelling of anoxic bottom water mass have been frequently observed in northeast part of Tokyo Bay in Japan during summer to autumn. Since the colour of water surface becomes milkyblue or milkygeen, the upwelling phenomenon Is called 'Blue Tide'. The data analysis of field surveys during 'Blue Tide' appearance have been performed for understanding the physical features of the 'Blue Tide' phenomena In Tokyo Bay. It becomes clear that (1) the formation of the anoxic bottom water correlates well with the temperature difference between the surface and bottom waters, (21 there are two necessary conditions for generating 'Blue Tide': that Is, strong stratincation and off-shore wind. The strong southwest(on-shored wand before the 'Blue Tide' appearance may play an iniportant role to make the striancation strengthen. When these conditions are larger and the northeast or east-northeast (off-shored wind stronger than S ifs blows In succession, the 'Blue Tide' upwelling appears at the head of Tokyo Bay.

  • PDF

A Medium-Voltage Matrix Converter Topology for Wind Power Conversion with Medium Frequency Transformers

  • Gu, Chunyang;Krishnamoorthy, Harish S.;Enjeti, Prasad N.;Zheng, Zedong;Li, Yongdong
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1166-1177
    • /
    • 2014
  • A new type of topology with medium-frequency-transformer (MFT) isolation for medium voltage wind power generation systems is proposed in this paper. This type of converter is a high density power conversion system, with high performance features suitable for next generation wind power systems in either on-shore or off-shore applications. The proposed topology employs single-phase cascaded multi-level AC-AC converters on the grid side and three phase matrix converters on the generator side, which are interfaced by medium frequency transformers. This avoids DC-Link electrolytic capacitors and/or resonant L-C components in the power flow path thereby improving the power density and system reliability. Several configurations are given to fit different applications. The modulation and control strategy has been detailed. As two important part of the whole system, a novel single phase AC-AC converter topology with its reliable six-step switching technique and a novel symmetrical 11-segment modulation strategy for two stage matrix converter (TSMC) is proposed at the special situation of medium frequency chopping. The validity of the proposed concept has been verified by simulation results and experiment waveforms from a scaled down laboratory prototype.

Economic Considerations Underlying the Adoption of HVDC and HVAC for the Connection of an Offshore Wind Farm in Korea

  • Hur, Don
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.157-162
    • /
    • 2012
  • Wind energy is created in mega-sized wind farms situated kilometers off shore. In fact, two possibilities are considered for the transmission system between the offshore wind farm and the onshore grid: high-voltage direct current and high-voltage alternating current. From this point of view, the current paper aims to compare both systems for a 2 GW wind farm situated 80 km from the Point of Common Coupling on an economic basis using a discounted cash flow analysis. A tool is developed in Microsoft Excel to allow for quick insight in the variation of input parameters.