• Title/Summary/Keyword: Off-grid

Search Result 217, Processing Time 0.034 seconds

Ionospheric Modeling at North-East Asia using IGS sites

  • Choi, Byung-Kyu;Park, Jong-Uk;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.195-198
    • /
    • 2006
  • One of the major sources of error in precise GPS positioning since the turn-off the Selective Availability(SA) is the ionospheric propagation delay. For the last decades, a lot of the ionospheric researches based on a GPS network have been implemented throughout the world. Especially researches of the ionospheric modeling for Wide Area Argumentation System(WAAS) have been undertaken and published. In mid-latitude regions, typical spatial and temporal variations in ionospheric models delay tend to minimal. The developed ionospheric model calls for a 1.25 degree grid at latitudes and a 2.5 degree grid at longitudes. The precise grid TEC estimated by the inversion technique is also compared with global ionosphere maps(GIMs) which have been provided by several analysis centers(ACs). The results of initial investigations into the suitability of the proposed ionospheric modeling scheme in north-east Asia are presented.

  • PDF

Ionospheric Modeling at North-East Asia using IGS sites

  • Choi, Byung-Kyu;Park, Jong-Uk;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.199-202
    • /
    • 2006
  • One of the major sources of error in precise GPS positioning since the turn-off the Selective Availability(SA) is the ionospheric propagation delay. For the last decades, a lot of the ionospheric researches based on a GPS network have been implemented throughout the world. Especially researches of the ionospheric modeling for Wide Area Argumentation System(WAAS) have been undertaken and published. In mid-latitude regions, typical spatial and temporal variations in ionospheric models delay tend to minimal. The developed ionospheric model calls for a 1.25 degree grid at latitudes and a 2.5 degree grid at longitudes. The precise grid TEC estimated by the inversion technique is also compared with global ionosphere maps(GIMs) which have been provided by several analysis centers(ACs). The results of initial investigations into the suitability of the proposed ionospheric modeling scheme in north-east Asia are presented.

  • PDF

Secure Distributed Data Management Architecture for Consumer Protection of Smart Grid (스마트 그리드의 소비자 보호를 위한 안전한 분산 데이터 관리 구조)

  • Park, Nam-Je;Song, You-Jin;Park, Kwang-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.57-67
    • /
    • 2010
  • Smart grid technology can expand energy efficiency into the home by monitoring consumer energy usage in real time and communicating with household devices that respond to demands to shut off during periods of non-use, allowing individual consumers to control their electricity usage more effectively. But, the information collected on a smart grid will form a library of personal information, the mishandling of which could be highly invasive of consumer privacy. There will be major concerns if consumer-focused principles of transparency and control are not treated as essential design principles from beginning to end. In this paper, using. All-Or-Nothing Transform encryption mode for providing smart grid security, we propose efficient distributed data Management based on XOR operation. The contribution of this paper is to provide a secure algorithm that manages efficiently distributed data in the field of private data in smart grid environment.

A Robust PLL of PCS for Fuel Cell System under Unbalanced Grid Voltages (불평형 계통전압에 강인한 연료전지용 전력변환시스템의 PLL 방법)

  • Kim, Yun-Hyun;Kim, Wang-Rae;Lim, Chang-Jin;Kim, Kwang-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.103-105
    • /
    • 2008
  • In grid-interconnection system, a fast, robust and precise phase angle detector is most important to grid synchronization and the active power control. The phase angle can be easily estimated by synchronous dq PLL system. On the other hand under unbalanced voltage condition, synchronous dq PLL system has problem that harmonics occur to phase angle or magnitude of grid voltage because of the effect of the negative sequence components. So, To eliminate the negative sequence components, the PLL method using APF (All Pass Filter) in a stationery reference frame to extract positive sequence components under unbalanced voltage condition is researched. In this paper, we propose a new PLL method with decoupling network using APF in a synchronous reference frame to extract the positive sequence components of the grid voltage under unbalanced grid. The cut-off frequency of APF in a synchronous reference frame can be set to twice of the fundamental frequency comparing with that of APF in a stationery reference frame which is the fundamental frequency. The proposed PLL strategy can detect the phase angle quickly and accurately under unbalanced gird voltages. Simulation and experimental results are presented to verify the proposed strategy under different kind of voltage dips.

  • PDF

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

An Economic feasibility Analysis for New and Renewable Hybrid Energy System by using HOMER (HOMER를 이용한 신재생복합전력시스템의 경제성 분석 - Off-grid 도서지역을 중심으로 -)

  • Baek, Minho;Cho, Seulgi;Kim, Suduk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.75.2-75.2
    • /
    • 2011
  • 국내 유인도서의 상당수는 전력의 대부분을 디젤발전으로 생산한다. 향후 발전설비의 교체 혹은 증설이 있을 경우 신재생에너지원 설비의 보급 여지가 있다. 이에 본 연구는 울릉도에 화력발전 설비만을 증설했을 경우와 이를 신재생에너지복합시스템 설비로 대체했을 때의 경제적 타당성을 비교분석한다. 우리는 복합발전 시스템을 풍력터빈, PV, 소수력발전 등의 신재생에너지 설비, Batteries, Converter와 같은 보조전원, 저장 및 back up을 위한 flywheel과 Diesel generator등으로 구성했다. 분석에 사용한 HOMER(Hybrid Optimization for Energy Renewable)는 신재생에너지복합 발전시스템 분석에 사용되며 결과를 NPC(Net Present Cost)의 오름차순으로 제시하여 발전설비구성의 조합들 중 최적의 시나리오를 보여준다. 분석결과 울릉도의 경우 신재생에너지복합 발전의 보급이 잠재적으로 가능할 것으로 보인다. 또한 계통운영의 기술적인 측면을 감안할 경우 정밀한 분석이 가능할 것이다. 따라서 본 연구는 계통운영과 경제성분석 연구의 연계를 위한 사전연구로써 그 의미를 갖는다.

  • PDF

Development of 3kW Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발)

  • Yang, Seok-Hyun;Kim, Min-Jae;Choi, Se-Wan;Cho, Jun-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.

A Flow Analysis of Small Craft by Using CFD

  • Park, Ji-Yong;Jeong, Jin-Hee;Hwang, Tea-Wook;Lee, Sol-Ah;Kim, Kyung-Sung
    • Journal of Multimedia Information System
    • /
    • v.7 no.4
    • /
    • pp.269-276
    • /
    • 2020
  • The small craft including jet-board for leisure are commonly smaller than the general commercial vessels. For the floating vessel, the motion analysis is significantly important component to design the shape. It is, however, hardly predicting its behavior by using conventional boundary element method due to violating small amplitude assumption for potential theory. The computational fluid dynamics method can afford to simulate such small craft, but its grid system was not able to calculate motion, because movable body disturbs the grid system by confliction. The dynamics fluid body interaction model with over-set mesh system can be dealt with movable floating body under irregular ocean wave. In this study, several cases were considered to reveal that DFBI is essential method to predict floating body motion. The single phase simulate was conducted to establish the shape perfection, and then the validated vessel was simulated with ocean waves weather DFBI option on or off. Through the comparison, the results between the cases of DFBI on and off shows significantly difference. It was claimed that the DFBI was necessary not only to calculation body motion, but also to predict accurate drag and lift force on the floating body for small size craft.

Enhanced Dynamic Response of SRF-PLL System in a 3 Phase Grid-Connected Inverter (3상 계통연계형 인버터를 위한 SRF-PLL 시스템의 동특성 개선)

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.134-141
    • /
    • 2009
  • The new method is proposed to improve the dynamics of the phase angle detector during abrupt voltage dip caused by a grid fault. Usually, LPF(low pass filter) is used in the feedback loop of SRF(Synchronous Reference Frame) - PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. A better transient response can be obtained with the proposed design method for SRF-PLL by the analysis of linearized model of the PLL system including LPF. Furthermore, in the proposed method, the controller gain and LPF cut-off frequency are changed from normal value to transient value when the voltage disturbance is detected. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the experiment.

A Algorithm on Optimizing Traffic Network by the Control of Traffic Signal Timing (교통신호등 제어를 통한 교통망 최적화 알고리즘)

  • An, Yeong-Pil;Kim, Dong-Choon;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.5
    • /
    • pp.472-478
    • /
    • 2017
  • In this paper, we deals with optimizing traffic signal timing in grid networks by using a network topology design method. Optimizing traffic signal timing includes minimizing delay time delay between departure and destination by interlocking straight traffic signal in the minimum spanning tree(MST). On the assumption that users of network abide by the paths provided in this paper, this paper shows optimizing traffic signal timing in grid networks. the paths provided in this paper is gathered by using Dijkstra algorithm used in computer networks. The results indicate minimizing delay time of passing through the grid network and interlocking traffic signal in the grid network.