• Title/Summary/Keyword: Off-Axis

Search Result 500, Processing Time 0.027 seconds

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF

Effect of fringe divergence in fluid acceleration measurement using LDA (레이저 도플러 원리를 이용한 유체 가속도 측정)

  • Chun, Se-Jong;Nobach, Holger;Tropea, Cam;Sung, Hyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1546-1551
    • /
    • 2004
  • The laser Doppler technique is well-established as a velocity measurement technique of high precision for flow velocity. Recently, the laser Doppler technique has also been used to measure acceleration of fluid particles. Acceleration is interesting from a fluid mechanics point of view, since the Navier Stokes equations, specifically the left-hand-side, are formulated in terms of fluid acceleration. Further, there are several avenues to estimating the dissipation rate using the acceleration. However such measurements place additional demands on the design of the optical system; in particular fringe non-uniformity must be held below about 0.0001 to avoid systematic errors. Relations expressing fringe divergence as a function of the optical parameters of the system have been given in the literature; however, direct use of these formulae to minimize fringe divergence lead either to very large measurement volumes or to extremely high intersection angles. This dilemma can be resolved by using an off-axis receiving arrangement, in which the measurement volume is truncated by a pinhole in front of the detection plane. In the present study an optical design study is performed for optimizing laser Doppler systems for fluid acceleration measurements. This is followed by laboratory validation using a round free jet and a stagnation flow, two flows in which either fluid acceleration has been previously measured or in which the acceleration is known analytically. A 90 degree off-axis receiving angle is used with a pinhole or a slit.

  • PDF

Improved Differential Wavefront Sampling algorithm for efficient alignment of Space optical system

  • Kim, Yun-Jong;Yang, Ho-Soon;Lee, Yun-Woo;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.34.4-35
    • /
    • 2008
  • The significant I&T process gain represented by reduction in overall budget expenditure can be obtained from the use of efficient alignment technique for large space optical systems. Such process gain tends to increase rapidly with an increase in aperture and/or in number of optical elements within the system. However, in practice, the alignment of multiple optical components tends to be rather difficult task because of the multiple coupling effects among the elements within the target system. In order to understand and hence identify the complex interplay of the wavefront coupling effects from the alignment process, the original differential wavefront sampling(DWS) method was presented elsewhere in recent years. DWS uses partial differential of the wavefront of optical component and perturbation value of the optical component against a particular alignment factor. The straightforward application of DWS for an off-axis optical system revealed that it tends to give incorrect estimation of the given misalignment state. In this study, we added off-axis correction terms to the original DWS algorithm and investigated its alignment performance. The performance simulation result for a Korsch type space optical system shows that the modified DWS is capable of bringing the misaligned system into the target alignment tolerance only after 3 iterations. It also shows that this new improved algorithm can be used to estimate the source misalignment as well. We are planning to apply this method for the alignment of a 800mm Korsch type telescope in the near future. We discuss the computational technique, simulation results and implications in details.

  • PDF

Research on the optimization of off-axis illumination condition and sub-resolution pattern size for the $0.1{\mu}m$ rule dense pattern formation ($0.1{\mu}m$급 dense 패턴 형성을 위한 사입사 조명 조건과 OPC 보조 패턴 크기의 최적 조건에 관한 연구)

  • 박정보;이재봉;이성묵
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.190-199
    • /
    • 2001
  • In this paper, we have researched the depth of focus (DOF) and cutoff intensity of the $0.1{\mu}m$rule dense line'||'&'||'space pattern according to the various off-axis illumination (OAl) conditions in the optical system of 0.65 NA using ArF excimer laser (193 nm). We have also studied the variation of the DOF and cutoff intensity according to the sub-resolution pattern (hammer head type) size for optical proximity correction (OPC) applied to the capacitor pattern and the various OAl conditions in the same optical system. As a result, it is revealed that the cross type quadrupole or annular illumination is preferred to the conventional X type quadrupole for printing the $0.1{\mu}m$ rule dense pattern. Also, we can investigate the optimal illumination condition and the size of ope sub-resolution pattern to keep a consistent DGF and cutoff intensity trends.

  • PDF

Dielectric Properties of $Ta_2O_5-SiO_2$ Thin Films Deposited at Room Temperature by Continuous Composition Spread (상온에서 연속 조성 확산법에 의해 증착된 $Ta_2O_5-SiO_2$ 유전특성)

  • Kim, Yun-Hoe;Jung, Keun;Yoon, Seok-Jin;Song, Jong-Han;Park, Kyung-Bong;Choi, Ji-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.2
    • /
    • pp.35-40
    • /
    • 2010
  • The variations of dielectric properties of $Ta_2O_5-SiO_2$ continuous composition spread thin films prepared by off-axis radio-frequency magnetron sputtering were investigated. The dielectric maps of dielectric constant and loss were plotted via 1500 micron-step measuring. The specific points showing superior dielectric properties of high dielectric constant (k~19.5) and loss (tan${\delta}$<0.05) at 1 MHz were found in area of the distance of 16 mm and 22 mm apart from $SiO_2$ side in $75{\times}25mm^2$ sized Pt/Ti/$SiO_2$/Si(100) substrates.

Measurement of Dose Distribution in Small Fields of NEC LINAC 6 MVX Using Films and Tissue Equivalent Phantoms (필름 및 tissue equivalent 팬톰을 이용한 NEC LINAC 6 MVX 소조사면에 대한 선량분포 측정)

  • Suh, Tae-Suk;Park, Dong-Rak;Choe, Bo-Young;Yoon, Sei-Chul;Jang, Hong-Seok;Park, Il-Bong;Kim, Moon-Chan;Bahk, Yong-Whee;Shin, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.9-17
    • /
    • 1993
  • The purpose of this paper is to develop a simple system to measure dose distribution in small fields of NEC LINAC 6 MVX using film and solid water instead of ion chamber and water phantom. Specific quantities measured include percent depth dose (PDD), off-axis ratio (OAR). We produced square fields of 1 to 3cm in perimeter in 1cm steps measured at SAD of 80cm. The PDD and OAR measured by film was compared with measurement made with ion chamber. We calculated the TMR from the basic PDD data using the conversion formula. The trends of our measured beam data and philips LINAC are similar each other. The measurement for the small field using film and solid water was simple. Hand-made film phantom was especially useful to measure OARs for the stereotactic radiosurgery.

  • PDF

Development of diameter 450 mm Cassegrain tlne collimator (직경 450 mm Cassegrain 형태 시준장치의 제작)

  • 양호순;이재협;이윤우;이인원;김종운;김도형
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.241-247
    • /
    • 2004
  • The collimator is necessary for the assembly and evaluation of high resolution satellite telescope. Traditionally, the off-axis paraboloid has been used as a collimator. However, it has some disadvantages in that it can suffer from air turbulence when the focal length of a collimator is long, which may result in some error in the measurement. In contrast, since the Cassegrain type collimator folds the beam, it occupies smaller space compared to the off-axis paraboloid for the same focal length. This can reduce the air turbulence, which can improve the measurement accuracy. In this paper, we explain the process of design and manufacturing of a diameter 450 mm Cassegrain type collimator, to evaluate the diameter 300 mm satellite telescope. After assembly of primary and secondary mirrors, the final wavefront error of the collimator was 0.07λ(λ=633 nm), which is the diffraction limit.

Holographic Forensic Mark based on DWT-SVD for Tracing of the Multilevel Distribution (다단계 유통 추적을 위한 DWT-SVD 기반의 홀로그래피 포렌식마크)

  • Li, De;Kim, Jong-Weon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2C
    • /
    • pp.155-160
    • /
    • 2010
  • In this paper, we proposed a forensic mark algorithm which can embed the distributor's information at each distribution step to trace the illegal distribution path. For this purpose, the algorithm has to have the high capacity payload for embedding the copyright and user information at each step, and the embedded information at a step should not interfere with the information at other step. The proposed algorithm can trace the multilevel distribution because the forensic mark is generated by digital hologram and embedded in the DWT-SVD domain. For the high capacity embedding, the off-axis hologram is generated from the forensic mark and the hologram is embedded in the HL, LH, HH bands of the DWT to reduce the signal interference. The SVD which is applied the holographic signal enhanced the detection performance and the safety of the forensic mark algorithm. As the test results, this algorithm was able to embed 128bits information for the copyright and user information at each step. In this paper, we can embed total 384bits information for 3 steps and the algorithm is also robust to the JPEG compression.

Simulation study of ion-implanted 4H-SiC p-n diodes (이온주입 공정을 이용한 4H-SiC p-n diode에 관한 시뮬레이션 연구)

  • Lee, Jae-Sang;Bahng, Wook;Kim, Sang-Cheol;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.131-131
    • /
    • 2008
  • Silicon carbide (SiC) has attracted significant attention for high frequency, high temperature and high power devices due to its superior properties such as the large band gap, high breakdown electric field, high saturation velocity and high thermal conductivity. We performed Al ion implantation processes on n-type 4H-SiC substrate using a SILVACO ATHENA numerical simulator. The ion implantation model used a Monte-Carlo method. We studied the effect of channeling by Al implantation simulation in both 0 off-axis and 8 off-axis n-type 4H-SiC substrate. We have investigated the Al distribution in 4H-SiC through the variation of the implantation energies and the corresponding ratio of the doses. The implantation energies controlled 40, 60, 80, 100 and 120 keV and the implantation doses varied from $2\times10^{14}$ to $1\times10^{15}cm^{-2}$. In the simulation results, the Al ion distribution was deeper as increasing implantation energy and the doping level increased as increasing implantation doses. After the post-implantation annealing, the electrical properties of Al-implanted p-n junction diode were investigated by SILV ACO ATLAS numerical simulator.

  • PDF

위성탑재용 카메라 광학부 예비설계

  • Lee, Seung-Hoon
    • Aerospace Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.177-187
    • /
    • 2002
  • Some kinds of precision optical systems for spaceborne high resolution cameras were designed at preliminary design level and an optical design for a hyperspectral imager was performed for its development model. A Cassegrain-based catadioptric system and an unobscured reflective triplet system are illustrated in detail for spaceborne high resolution electro optical cameras which have performance of 5m resolution at an altitude of 685km and the design are evaluated in its spot-diagram and MTF to prove they have good performance enough to implement the requirements for realistic satellite payload taking the fabrication conditions and the on-orbit operation into consideration. For the development of hyperspectral imager as a next-generation payload, an optical system has been designed and elaborated. It can be divided into two parts, a catoptric telescope forming an off-axis 2 mirror type and a dispersive spectrometer which comprises collimator, grating and reimaging lens cell. From its optical design to the system characteristics are shown with the MTF performance reaching 25% approximately.

  • PDF