• 제목/요약/키워드: Odorous gas

Search Result 61, Processing Time 0.447 seconds

A Study on an experimental basis a use deodorize stink of food-waste in order to cooling dehumidification (냉각 제습에 의한 음식물 쓰레기 처리장치 악취제거에 관한 실험적 연구)

  • Park, I.S.;Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • This paper presents an effective cooling dehumidification method to remove odorous gas from food-wastes. The odorous gases, such as Styrene, Ammonia, Hydrogen sulfide and Acetaldehyde, are produced in environments where temperature is $50\sim80^{\circ}C$ and humidity is $40\sim70%$. Under such conditions, experiments are performed reiteratively using experiment equipments. The effect of the cooling dehumidification is measured via measuring instrument, and this research is focused on improving efficiency. The effect of cooling dehumidification using measuring instrument is validated. At $80^{\circ}C$, four type of gases that was mentioned previously showed generally better cooling efficiency with a good result for a component concentration. Among them, hydrogen sulfide gas demonstrated the highest reduction of 50%.

  • PDF

Aqeous Neutralizer as Reactive Solvents for Odorous Ammonia Removal

  • Park, Young-G.
    • Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.119-124
    • /
    • 2008
  • Ammonia is an inorganic compound that may cause severe odor problem. In this study the effectiveness of applying natural neutralizer to destroy and remove the odor-causing compound from gas streams was studied. Experimental result evaluated with a bench-scale apparatus via the neutralization of gas phase. This indicates that the natural neutralization depends on the gas concentration, gas residence time, temperature and pH. Removal efficiency of ammonia from gas stream was achieved by 95% using theconvection in the packed bed. This study proved the chemical neutralization technology was effective for controlling inorganic odor-causing compound.

Reduction of the Offensive Odor from Confectionery Wastewater Plant (제과공장의 폐수처리장에서 발생하는 악취 저감)

  • 김영식;손병현;조상원;정종현
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

By the GNC Solution, Removal Effect Offensive Odorous Compounds Generated from Food (GNC용액을 이용한 음식물 쓰레기처리장에서 발생되는 악취 규제물질 제거 효과에 관한 연구)

  • Hong, Jong-Soon;Kim, Jae-Woo
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.2
    • /
    • pp.35-40
    • /
    • 2007
  • It disposes positively in the air pollution damage which is serious, in order help period the place where it improves the quality of existence and life of the local residents. It removed the offensive odor regulation material and the technique it will be able to prevent to sleep it researched it did. After scattering the GNC solution which develops the offensive odor regulation material which occurs from the food and trash treatment plant which is located to the S from the H, company after scattering the GNC solution which it develops collection it did a control criminal record control kind air and it analyzed. In this study, we investigated the emission concentrations of offensive odorous compounds of hydrogen sulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide, trimethylamine, formaldehyde, acetaldehyde, propionaldehyde, buthylaldehyde, iso-valeric aldehyde, n-valeric aldehyde, ammonia. The concentrations of odorous compounds are determined by gas chromatography, HPLC and uv-vis spectroscopy. Hydrogen sulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide were not detected at any point examined.

Emission Characteristics of VOCs in Drying Process for Plywood Manufacturing (합판 제조용 목재 건조공정에서의 휘발성 유기화합물(VOCs) 배출특성)

  • Jang, Jeong-Gook;Kim, Mi-Ran
    • Journal of Environmental Science International
    • /
    • v.17 no.12
    • /
    • pp.1381-1390
    • /
    • 2008
  • Emission characteristics of volatile organic compounds (VOCs) were investigated in the flue gas emitted from wood drying process for plywood manufacturing. The moisture content of raw timber was average 48%, and its density was $831.55kg/m^3$. But the moisture content of dried wood is needed less than around 10%, thus the moisture contents of flue gas should be remarkably high(about 18.2 V/V%). Therefore, the vapor in flue gas is equivalent to 320 ton-vapor/day when 1100 ton-wood/day is treated in the wood drying process. The temperature of flue gas ranges from $140^{\circ}C\;to\;150^{\circ}C$ in each dryer stack with exception of the input site of wood(about $110^{\circ}C$). The velocity of flue gas in each stack ranges from 1.7 to 9.7m/sec. In order to assess the concentrations and attribution rate of odorous compounds, it was analyzed about 40 VOCs in the flue gases. It was found that the major odorous compounds were 8 compounds, and the concentrations of major VOCs(ppm) were as follows; benzene: $0.054{\sim}0.052$, toluene: $1.011{\sim}2.547$, ethylbenzene: $0.472{\sim}2.023$, m,p-xylene: $0.504{\sim}3.245$, styrene: $0.015{\sim}0.148$, o-xylene : $0.271{\sim}1.097$, ethanol: $11.2{\sim}32.5$, ${\alpha}$-pinene: $0.908{\sim}10.578$, ${\beta}$-pinene: $0.982{\sim}14.278$. The attribution rate of terpenes (${\alpha}$-pinene, ${\beta}$-pinene) was about 60.56%, and that of aromatics and alcohols was about 22.77%, and 16.67%, respectively. It is suggested that the adequate control device should be used to control both the water soluble and non-soluble compounds because both compounds were mixed in flue gas.

Emission Characteristics of Odor Compounds from Pneumatic Waste Collection Plants (생활폐기물 자동집하시설의 악취물질 배출특성)

  • Yoon, Yongkyeong;Kim, Daekeun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.541-548
    • /
    • 2012
  • The objective of this study was to investigate emission characteristics of odorous compounds from the pneumatic waste collection plants (namely, A and B sites). The air samples were collected from each site, at a carrier gas inside the plant and an exhaust gas, to analyze complex odor and 22 odorous compounds. Ammonia, sulfur compounds, and acetaldehyde were the critical odorous components generated in the plants studied. Characteristics of odor at exhaust outlet varied according to the type of odor control engineering. In the analysis of the odor contribution degree of odor components based on odor threshold, site A shows that the odor contribution of dimethyl sulfide was found to be 26%, acetaldehyde 18%, and methyl mercaptan 14%. For site B, methyl mercaptan was 56% and both hydrogen sulfide and dimethyl sulfide were 15%.

On-line GC Analysis of Odorous VOC and S Gas Pollutant Levels in Ambient Air of a Residential Area at Ansan City, Korea (안산시 주거지역을 중심으로 한 환경대기 중 휘발성 유기화합물과 황계열 성분의 온라인 연속측정 연구)

  • Kim K.-H;Ju DW;Choi YJ;Hong YJ;Sa JH;Park JH;Jeon EC;Choi CR;Koo YS
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.1
    • /
    • pp.107-118
    • /
    • 2005
  • In this study, the concentrations of major odorous compounds including reduced sulfur compounds (OMS, CS$_2$, and DMDS) and aromatic VOC (benzene, toluene, xylene, etc.) were measured continuously using an on-line GC analytical system. Our measurements were made from a residential area of Ansan sity during about two week period of October, 2004. The highest mean concentrations of Sand VOC were found as 56.9 pbb of DMS and 21.7 ppb of toluene, respectively. The results of this study generally show that the pollution levels for both types of chemicals are significant relative to previous measurement results reported from comparable sites, if the results are compared simply in terms of the magnitude of the measured concentration data. Moreover, when the relative importance of different compounds is compared in terms of the odor strength, it indicated that the contribution of reduced S compounds may be much more important than that of VOC in the study area.

Odor Removal by Using Compost and Granular Scrap Tires (퇴비 및 폐타이어 Granule을 이용한 악취 제거)

  • Chung, Yoon-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • In spite of low energy requirement, and operation and construction cost, biofilters with soil beds have not been operated efficiently. Because of excess moisture in winter and rainy periods, saturated pores in the bed prevent passage and sorption of odorous compounds. Sometimes this results in septic conditions that release previously sorbed and oxidized sulfur. Therefore, an economical and effective alternative needs to be developed. The objectives of this study were to confirm applicability of the granular scrap tires with compost for treating odorous gas as well as to obtain optimum design parameters for proposed system. In lab-scaled test, multiple stage reactors had lower headloss than a single stage reactor and less headloss was occurred for the gas with higher moisture content. For practical purpose, pilot-scaled reactor was operated to remove odor from septic tank, manure and animal wastewater treatment plant and composting machine. According to the results of pilot scaled test, $H_2S$ can be always removed completely and ammonia/amine can be removed excellently when proper moisture content is provided. The results from lab and pilot test showed that granular scrap tire could be replaced with soil as supporting material for biofilter showed excellent drainage because of its ability to reject moisture.

  • PDF

Decomposition of Odorous Gases in a Pilot-scale Nonthermal Plasma Reactor

  • Hwang, Yoon-Ho;Jo, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.57-65
    • /
    • 2005
  • An experimental study was performed on the decomposition of gaseous ammonia and two selected volatile organic compounds (VOCs: toluene and acetone) in a combined nonthermal plasma reactor with corona and glow discharges. A lab pilot scale reactor (206 liter) equipped with a high electric power pack was used to determine the decomposition efficiency in relation with the inlet concentration and applied voltage. Three different types of discharging electrode such as wired rack, wire strings for corona discharge, and thin plate for glow discharge were put in order in the reactor. While decomposition of ammonia decreased with an increase in the initial concentration, acetone showed an opposite result. In the case of toluene however no explicit tendency was found in toluene and aceton. Negative discharge resulted in high decomposition efficiency than the positive one for all gases. A better removal of gas phase element could be achieved when fume dust were present simultaneously.

Simultaneous Analyses for Trace Multi-Odorous and Volatile Organic Compounds in Gas using a Triple-bed Adsorbent Tube (Triple-bed Adsorbent Tube를 이용한 가스상 극미량 복합 악취 및 휘발성 유기화합물의 동시 분석)

  • Seo, Yong Soo;Lee, Jea Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.244-252
    • /
    • 2010
  • The objective of this study is to assess feasibility of simultaneous analysis for trace multi-components odorous and volatile organic compounds using a Triple-bed adsorbent tube with a thermal desorber and GC-MS. Triple-bed adsorbent tube is 3 bed packed Tenax-TA with small amount of Carbopack B and Carbosieve SIII in order of adsorption strength in a tube. The operating conditions of GC-MS was possibly able to and effectively detect high volatile and low molecular weight compounds at the mass range of 20~350 m/z using a below impurity 1ppm of Helium carrier gas, of which quantitatively analyzed by target ion extracts. According to the experiment, $C_1{\sim}C_5$ of 14 components; sulfur containing compounds(2), ketones(2), alcohols(4) and aldehydes(6) were simultaneously analyzed with recoveries of 99%, and good repeatability and linearity. High volatile and low molecular weight compounds such as methyl alcohol and acetaldehyde can be safely quantified with high recovery at a condition of 50mL/min of flow rate, below 2L of adsorption volume, and 45% of relative humidity. Target ion extract can also simultaneously quantify multicomponents with odorous and volatile organic compounds in an occasion of piled up two peaks.