• Title/Summary/Keyword: Odorous Compounds

Search Result 119, Processing Time 0.055 seconds

Dispersion Characteristics of Odorous Elements from Nambu Wastewater Treatment Plant and a Nearby Streams in Busan (부산시 남부하수처리시설과 인근 하천에서 발생하는 악취물질 확산 특성)

  • Mun, Seong-Man;Lee, Hyung-Don;Cho, Sang-Won;Kang, Dong-Hyo;Park, Hae-Sik;Oh, Kwang-Joong
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.953-962
    • /
    • 2011
  • The covered stream of cities are considered an odor source. Also, the public do not want a wastewater treatment plant(WWTP) near their properties due to the emission of odor emanating from such sources, although they play an important role in urban development. The purpose of this study is to analyze the pattern distribution of the odorous compounds from the Nambu WWTP and Youngho stream in Busan. odor sampled four times were analyzed by instrumental analysis method and indirect olfactory method. The kinds of offensive odorous compounds examined are acetaldehyde, propion aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and ammonia. Also, Concentration of air pollutants has been calculated by ISCST3 models. At the result of this study, The Nambu WWTP releases sulfur compounds. And the major odorous were hydrogen sulfide (1,475 ppb) and acetaldehyde (95 ppb) at Youngho stream. The stink which residents feel will point out the Nambu WWTP mainly if the odor is removed with the improvement of a Youngho stream. Accordingly, we should pay more attention to appropriate components to processes in odor reducing plan at Nambu WWTP.

The investigation of combined ventilation-biofilter systems using recycled treated wastewater on odor reduction efficiency

  • Febrisiantosa, Andi;Choi, Hong L.;Renggaman, Anriansyah;Sudiarto, Sartika I.A.;Lee, Joonhee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.7
    • /
    • pp.1209-1216
    • /
    • 2020
  • Objective: The present study aimed to evaluate the performance of odor abatement by using two different ventilation-biofilter systems with recycled stablized swine wastewater. Methods: The performance of odor removal efficiency was evaluated using two different ventilation-biofilter-recycled wastewater arrangements. A recirculating air-flow ventilation system connected to a vertical biofilter (M1) and a plug-flow ventilation system connected to a horizontal biofilter (M2) were installed. Water dripping over the surface of the biofilter was recycled at a flow rate of 0.83 L/h in summer and 0.58 L/h in winter to reduce odorous compounds and particulate matter (PM). The experiments were performed for 64 days with M1 and M2 to investigate how these two ventilation-biofilter systems influenced the reduction of odor compounds in the model houses. Odorous compounds, NH3 and volatile organic compounds (VOCs) were analyzed, and microclimatic variables such as temperature, humidity, and PM were monitored. Results: Ammonia concentration inside M1 was about 41% higher on average than that in M2. PM and total suspended particles (TSPs) inside M1 were about 62.2% and 69.9%, respectively, higher than those in M2. TSPs in the model house were positively correlated with the concentration of NH3 and VOCs. Conclusion: M2 emitted lower concentration of odorous compounds than M1. Moreover, M2 could maintain the optimum temperature condition for a swine house during the cooler season. The plug-flow ventilation-horizontal biofilter system could be used for pig houses to minimize air pollution produced by swine farming activities and maintain optimum microclimate conditions for pigs.

Evaluation of Complex Odor and Odorous Compounds in a Pilot-Scale Ultra Thermophilic Aerobic Composting Process (초고온 호기성 퇴비화 공정의 복합 악취 및 악취 물질 평가)

  • Park, Seyong;Jung, Dai-Hyuck;Yoo, Eui-Sang;Kim, Moonil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.5
    • /
    • pp.33-39
    • /
    • 2009
  • This study was conducted to evaluate production of complex odor and 12 specific odorous compounds in a pilot-scale (capacity : $100m^3$) ultra thermophilic aerobic composting. There were three types input: municipal wasted sludge, livestock manure and slurry, and food waste produced in Jung-Eb city. Each raw material was mixed with seed material and operated for two periods (1st : 50 days, 2nd : 60days). During composting, the temperature hit $90{\sim}95^{\circ}C$ after every mixing in both periods. Therefore, it was concluded that increasing temperature also saves the time which required for composting and high reduction of organics and water contents. The primary odorous compounds were ammonia, methyl mercaltan, dimethyl disulfide and trimethylamine. The concentration of the primary compounds and complex odor during the operation were higher than those on final day and most compounds did not exceed the allowable exhaust standard for odor. Also, it was found that optimal mixing time and control of high temperature are the most important parameters for odor control in ultra thermophilic aerobic composting.

  • PDF

Removal of nitrogen and sulfur odorous compounds and their precursors using an electrolytic oxidation process (산화전리수를 이용한 질소와 황 계열 악취 및 악취전구물질의 제거)

  • Shin, Seung-Kyu;An, Hea-Yung;Kim, Han-Seung;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.223-230
    • /
    • 2011
  • An electrolytic oxidation process was applied to remove odorous compounds from non-point odor sources including wastewater pipelines and manholes. In this study, a distance between the anode and the cathode of the electrolytic process was varied as a system operating parameters, and its effects on odor removal efficiencies and reaction characteristics were investigated. Odor precursors such as sediment organic matters and reduced sulfur/nitrogen compounds were effectively oxidized in the electrolytic process, and a change in oxidation-reduction potential (ORP) indicated that an stringent anaerobic condition shifted to a mild anoxic condition rapidly. At an electrode distance of 1 cm and an applied voltage of 30 V, a system current was maintained at 1 A, and the current density was 23.1 $mA/cm^{2}$. Under the condition, the removal efficiency of hydrogen sulfide in gas phase was found to be 100%, and 93% of ammonium ion was removed from the liquid phase during the 120 minute operating period. Moreover, the sulfate ion (${SO_4}^{2-}$) concentration increased about three times from its initial value due to the active oxidation. As the specific power consumption (i.e., the energy input normalized by the effective volume) increased, the oxidation progressed rapidly, however, the oxidation rate was varied depending on target compounds. Consequently, a threshold power consumption for each odorous compound needs to be experimentally determined for an effective application of the electrolytic oxidation.

Simultaneous Analyses for Trace Multi-Odorous and Volatile Organic Compounds in Gas using a Triple-bed Adsorbent Tube (Triple-bed Adsorbent Tube를 이용한 가스상 극미량 복합 악취 및 휘발성 유기화합물의 동시 분석)

  • Seo, Yong Soo;Lee, Jea Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.244-252
    • /
    • 2010
  • The objective of this study is to assess feasibility of simultaneous analysis for trace multi-components odorous and volatile organic compounds using a Triple-bed adsorbent tube with a thermal desorber and GC-MS. Triple-bed adsorbent tube is 3 bed packed Tenax-TA with small amount of Carbopack B and Carbosieve SIII in order of adsorption strength in a tube. The operating conditions of GC-MS was possibly able to and effectively detect high volatile and low molecular weight compounds at the mass range of 20~350 m/z using a below impurity 1ppm of Helium carrier gas, of which quantitatively analyzed by target ion extracts. According to the experiment, $C_1{\sim}C_5$ of 14 components; sulfur containing compounds(2), ketones(2), alcohols(4) and aldehydes(6) were simultaneously analyzed with recoveries of 99%, and good repeatability and linearity. High volatile and low molecular weight compounds such as methyl alcohol and acetaldehyde can be safely quantified with high recovery at a condition of 50mL/min of flow rate, below 2L of adsorption volume, and 45% of relative humidity. Target ion extract can also simultaneously quantify multicomponents with odorous and volatile organic compounds in an occasion of piled up two peaks.

A Study on Emission Characteristics of Odor Compounds from Waste Transfer Station (적환장에서 발생하는 악취 분포 특성에 관한 연구)

  • Jeon, Jae-Sik;Kim, Eun-Sook;Yoo, Seung-Sung;Oh, Seok-Ryul;Choi, Han-Young
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.418-425
    • /
    • 2013
  • Objective: This study was carried out for the purpose of identifying major substances contributing to the production of odor and evaluating the characteristic of odors. Methods: Complex odor and 17 odorous compounds were measured at 18 waste transfer stations located in Seoul. Results: The dilution ratio value of complex odor ranged from 4 to 30 times in the boundary layer of 18 waste transfer stations. At 6 measurement points among the 18 waste transfer stations, the dilution ratio values exceeded standards (15 times). When the results were evaluated in terms of their contribution to the formation of malodor, the patterns indicated that the highest concentration values in the residential waste disposal process were of i-valeraldehyde and acetaldehyde, while butyraldehyde and acetaldehyde accounted for a large proportion of odorous compounds from the waste recycling process. Conclusions: It was found that butyraldehyde and acetaldehyde were the primary compounds released from the food waste disposal process. Overall, aldehyde compounds were the greatest contributor to detectable odor intensity emitted at the waste transfer stations.

Characterization of Odorant Compounds from Mechanical Aerated Pile Composting and Static Aerated Pile Composting

  • Kumari, Priyanka;Lee, Joonhee;Choi, Hong-Lim
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.4
    • /
    • pp.594-598
    • /
    • 2016
  • We studied airborne contaminants (airborne particulates and odorous compounds) emitted from compost facilities in South Korea. There are primarily two different types of composting systems operating in Korean farms, namely mechanical aerated pile composting (MAPC) and aerated static pile composting (SAPC). In this study, we analyzed various particulate matters (PM10, PM7, PM2.5, PM1, and total suspended particles), volatile organic compounds and ammonia, and correlated these airborne contaminants with microclimatic parameters, i.e., temperature and relative humidity. Most of the analyzed airborne particulates (PM7, PM2.5, and PM1) were detected in high concentration at SAPC facilities compered to MAPC; however these differences were statistically non-significant. Similarly, most of the odorants did not vary significantly between MAPC and SAPC facilities, except for dimethyl sulfide (DMS) and skatole. DMS concentrations were significantly higher in MAPC facilities, whereas skatole concentrations were significantly higher in SAPC facilities. The microclimate variables also did not vary significantly between MAPC and SAPC facilities, and did not correlate significantly with most of the airborne particles and odorous compounds, suggesting that microclimate variables did not influence their emission from compost facilities. These findings provide insight into the airborne contaminants that are emitted from compost facilities and the two different types of composting agitation systems.

The Composition of Odor Compounds Emitted from Municipal Solid Waste Landfill (도시 생활폐기물 매립지에서 발생되는 악취물질의 조성에 대한 연구)

  • Son, Youn-Suk;Kim, Jo-Chun;Kim, Ki-Hyung;Lim, Bo-A;Park, Kang-Nam;Lee, Woo-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.666-674
    • /
    • 2007
  • In this study, sampling and analysis was carried out for 13 compounds, in order to investigate the odorous compound emissions from landfill stacks and surrounding ambient air. These results revealed that concentration of hydrogen sulfide was $0.13{\sim}0.66\;ppb$ in the ambient air. Also, concentrations of hydrogen sulfide ($151{\sim}358\;ppm$) were the highest value in odorous sulfur compounds from landfill stacks. In case of VOC, toluene was obtained the highest out of volatile organic compounds. It was found that the concentrations of hydrogen sulfide near the landfill was higher than that inside city such as Seoul although it was located in a rural area. The result was due to the effect of hydrogen sulfide emitted from landfill stacks.

Emission Characteristics of Odor Compounds from Pneumatic Waste Collection Plants (생활폐기물 자동집하시설의 악취물질 배출특성)

  • Yoon, Yongkyeong;Kim, Daekeun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.541-548
    • /
    • 2012
  • The objective of this study was to investigate emission characteristics of odorous compounds from the pneumatic waste collection plants (namely, A and B sites). The air samples were collected from each site, at a carrier gas inside the plant and an exhaust gas, to analyze complex odor and 22 odorous compounds. Ammonia, sulfur compounds, and acetaldehyde were the critical odorous components generated in the plants studied. Characteristics of odor at exhaust outlet varied according to the type of odor control engineering. In the analysis of the odor contribution degree of odor components based on odor threshold, site A shows that the odor contribution of dimethyl sulfide was found to be 26%, acetaldehyde 18%, and methyl mercaptan 14%. For site B, methyl mercaptan was 56% and both hydrogen sulfide and dimethyl sulfide were 15%.