• Title/Summary/Keyword: Odor removal

Search Result 229, Processing Time 0.031 seconds

Odor Removal with Powdered Adsorbent using Bag-filter System (분말 흡착제를 이용한 악취 저감 여과 집진장치 개발연구)

  • Xu, Rong-bin;Kim, Tae-Hyeung;Ha, Hyun-Chul;Piao, Cheng-Xu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.291-301
    • /
    • 2017
  • Objectives: In order to improve the working environment and solve the complaints, many efforts have been made to remove the odor from the industrial process. There are many disposal methods to remove odor, but there are many disadvantages and inadequate applications. The Purpose of this study was to develop a bag-filer system for odor removal using powder adsorbent. Methods: The bag-filter system is composed of a shear bag filter, an absorbent spraying system and an absorbent circulation system. The spraying absorbent system was connected with the inlet duct of the shear bag filter for inputting adsorbent. And the absorbent circulation system can transport the collecting adsorbent from hoper to the inlet duct of the system. As a result, the adsorbent can remove odor with recycling in the system. Also affective factors like the powdered absorbent combination and injection method was researched for maximization of system efficiency. The study was conducted in two stages. The first step was testing equipment made and the second is to evaluate the efficiency of the odor control by connecting to the actual odor generation process. Results: Both experiment stages showed efficient odor control ability. The adsorption efficiency of the system is demonstrated and the odor was adsorbed well by the powder adsorbent. It is essential to accurately understand the characteristics of the odorous and use the appropriate adsorbent. Although the powder adsorbent was used in the experiment, the problem of scattering did not occur due to the high degree of system sealing. Also the system manufactured in this study was designed to recycle the adsorbent, so adsorbent reuse or batch processing is convenient. Conclusions: The applicability of the system has been proven through this research. Customized systems for industrial process and the appropriate adsorbent base on the characteristics of pollutant generation will show efficient odor collection ability.

Removal of Odor and THM from the Raw Water of Daecheong Dam (대청호 원수내 냄새 및 THM 제거방안 연구)

  • Jeon, Hang-Bae;Yun, Gi-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.3
    • /
    • pp.235-245
    • /
    • 1997
  • A pilot scale study for removing odor and trihalomethane formation potential (THMFP) was investigated in the standard water treatment plant equipped with ozone oxidation and granular activated carbon (GAC) adsorption processes. The removal efficiency of dissolved organic carbon (DOC) in the pilot scale standard water treatment process (PSWTP) was about 25%, however, no more removal in the ozone oxidation process. On a GAC after 30 days operation, DOC removal efficiency was about 75%. Odor removal efficiency was about 30% in PSWTP, 60% in ozone oxidation, and almost complete in well as DOC. Mid-1 and 2 that showed breakthrough in odor inducing material as well as DOC. Mid-1 and 2 chlorination was able to reduce trihalomethanes (THM) by 25% compared to prechloringation, while postchlorination alone could reduce them by 30%.

  • PDF

Removal of Alkali Odors using Impregnated ACFs (첨착 ACF를 이용한 염기성 악취물질의 제거)

  • 김기환;김덕기;최봉각;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.92-97
    • /
    • 1998
  • Malodorous gases give discomfort and harm to laborers and residential neighborhoods and therefore, the removing odor materials emitted from plants and industrial facilities is important subject. The main ingredients of alkali odor are $NH_3$ and $CE_3SH$. The adsorption characteristics of odors were studied using four different activated carbon fibers(ACF) and active carbon(AC). Alkali odor was removed by using ACF impregnated with $H_3PO_4$ and $H_2SO_4$ and treated with $HNO_3$ and NaOH. The experimental result showed that ACF has a higher removal efficiency than AC. The adsorption capacity was increased with the impregnation and surface treatment, and $H_2SO_4$ was the best impregnant for the removal of alkali odor.

  • PDF

Performance of Air Fresher System for the Removal of Various Odorants Released from Foodstuffs

  • Kim, Ki-Hyun;Adelodun, Adedeji A.;Deep, Akash;Kwon, Eilhann E.;Jeon, Eui-Chan;Kim, Yong-Hyun;Jo, Sang-Hee;Lee, Min-Hee;Cho, Sung-Back;Hwang, Ok-Hwa
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.37-53
    • /
    • 2017
  • The effectiveness of four air fresher (AF) systems was evaluated with respect to their removal efficiencies against offensive odorants. For this purpose, malodorous species were generated by exposing freshly cooked foods emitting odorants with levels moderately above their respective threshold values in a confined room. The deodorization efficiency of the four AF systems was then tested for a period of 30 min by estimating the extent of reduction in odorant levels after the operation of each AF. The removal efficiency of the four AF units against each odorant was evaluated as follows: (1) between AF products from different manufacturers, (2) between odorants and ultrafine particulate matter ($PM_{2.5}$), and (3) between operation and natural degassing. The average sorptive removal of odorants was generally <80% and considered less effective or non-effective relative to $PM_{2.5}$. Further examination of odor reduction, if evaluated in terms of odor indices like odor intensity (OI) and odor activity value (OAV), recorded a mean of 33% and 87%, respectively. The overall results of this study confirmed that all tested AF units were not effective to resolve odor problems created under our testing conditions.

Odor Emission from Sediments in Sewer Systems and Odor Removal using an Electrolytic Oxidation Process (하수관거에 퇴적된 유기물에 의한 악취 발생과 산화전리시스템을 이용한 악취 저감)

  • Ahn, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.703-710
    • /
    • 2011
  • Odor emission from domestic sewer systems has become a serious environmental problem. An investigation on a sewer manhole revealed that anaerobic decay of sediment organic matters (SOMs) and related declines of oxidation reduction potential (ORP) in the sediment layer were the main reason of the production of volatile sulfur compounds. In addition, as the anaerobic decaying period continued, the odor intensity rapidly increased with increasing concentrations of $H_2S$ and dimethyl sulfide. As a feasible method to control SOMs and to minimize odor emission potentials, an electrolytic oxidation process has been employed to the sediment sludge phase. In this study, voltages applied to the electrolytic oxidation process were varied as a main system parameter, and its effects on odor removal efficiencies and reaction characteristics were investigated. At the applied voltages greater than 20 V, the system efficiently oxidized the organic matter, and the ORP in the sludge phase increased rapidly. As a consequence, the removal efficiency of hydrogen sulfide was found to be >99% within 60 minutes of the electrolytic oxidation. Overall, the electrolytic oxidation process can be an alternative to control odor emission from sewer systems, and a threshold input energy needs to be determined to achieve effective operation of the process.

Aqeous Neutralizer as Reactive Solvents for Odorous Ammonia Removal

  • Park, Young-G.
    • Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.119-124
    • /
    • 2008
  • Ammonia is an inorganic compound that may cause severe odor problem. In this study the effectiveness of applying natural neutralizer to destroy and remove the odor-causing compound from gas streams was studied. Experimental result evaluated with a bench-scale apparatus via the neutralization of gas phase. This indicates that the natural neutralization depends on the gas concentration, gas residence time, temperature and pH. Removal efficiency of ammonia from gas stream was achieved by 95% using theconvection in the packed bed. This study proved the chemical neutralization technology was effective for controlling inorganic odor-causing compound.

Removal of Malodorous Gases from Swine Manure by a Polyurethane Biofilter Inoculated with Heterotrophic and Autotrophic Bacteria. (종속영양세균과 독립영양세균을 고정화한 Polyurethane Biofilter의 돈분뇨 악취제거)

  • 이연옥;조춘구;류희욱;조경숙
    • Microbiology and Biotechnology Letters
    • /
    • v.30 no.1
    • /
    • pp.91-97
    • /
    • 2002
  • Removal of malodorous gases from swine manure by a polyurethane biofilter inoculated with heterotrophic and autotrophic bacteria was investigated. Ammonia, hydrogen sulfide and other gases could be efficiently treated at 3~3.6 second of empty bed retention time by the polyurethane biofilter. In the range of SV $200~l,200h^{-1}$ , the average removal efficiency of odor was about 89% when the odor unit of inlet gas was below 4100. Odor elimination capacity of the polyurethane biofilter was$ 1.8$\times$10^{5}$ $~5.0$\times$10^{7}$OUㆍm$^{-3}$$h^{-1}$ that were 84~90% of the inlet load. The critical loads of $NH_3$ and $H_2$S, which mean 97% removal with respect to the inlet loads, were 31 and $27 g.m^{-3}$$h^{-1}$ , respectively. The maximum elimination capacities of $NH_3$ and $H_2$S were 56 and $157 gㆍm^{-3}$ ㆍh$^{-1}$ , respectively. Although the removability for$ NH_3$ and $H_2$S was not influenced by $H_2$S$NH_3$ ratio (ppmv/ppmv), the $H_2$S removability was inhibited by high $H_2$S concentration more than 80 ppmv.

Development of an Odor Abatement System for Swine Manure Treatment Facilities

  • Lee, S.H.;Yun, N.K.;Kim, G.W.;Yum, S.H.;Cho, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study was conducted to solve the problem of public grievance owing to odor of a pig farm. Odor emissions from pig production systems mainly originate from liquid manure storage and solid manure fermentation. The low-cost odor abatement system (OAS) for application at liquid manure storage tank and solid manure fermentation facilities was developed in this study. The OAS adapted odor removing principles of a biofilter and biotrickling filter. The OAS is very simplified in structure. The appearance of the OAS had a form of cylindrical or cubical shape. The system performance was monitored for about one year after stabilization. A 7 seconds empty bed contact time for the OAS was adapted to achieve the odor reduction levels. The commercial type of OAS was constructed with media comprised of wood chips. Moisture content always remained above 50% wet basis. Average ammonia removal efficiency for the developed design was 89% at the liquid manure storage tank. Also, the removal efficiency at a solid manure fermentation facility was 86% on ammonia.

  • PDF

Characteristic of odor from feed manufactory and evaluation of odor reduction efficiency using chemical scrubber (사료제조 공장의 발생악취 특성 및 약액세정탑을 이용한 악취저감효율 평가)

  • Lim, Ji-Young;Jeon, Yong-Bin;Song, Seung-Jun;Cho, Young-Gun;Kim, Jin-Han
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.389-395
    • /
    • 2018
  • The odor substances generated in a feed manufactory operating for the commercialization of animal-vegetable materials were analyzed and the odor reduction efficiency by a chemical scrubber was evaluated. The major causative substances in the feed manufactory comprised about 45.4% of ketone compounds and about 13.3% of aldehyde compounds. On the other hand, the removal efficiencies of diacetyl and acetoin as ketone compounds were 77.3% and 78.1%, respectively, by a chemical scrubber. Additionally, the removal efficiencies of acetaldehyde, butyraldehyde, valeraldehyde, 2-furancarboxaldehyde, and nonanal were 86.0%, 78.9%, 67.4%, 52.8%, and 71.9%, respectively. These rates were higher than the odor generation substance contribution rate as a result of treating the exhaust gas generated from the feed manufactory by the chemical scrubber using 5% of C3. It was also found that xylene, methylcyclopentane, benzene, ethylbenzene, 1,3,5-trimethylbenzene, and decane were almost not removed.

Ammonia Removal Characteristics by Pyroligneous Liquid at Livestock Farmhouse (축산농가에서 목초액을 이용한 암모니아 가스의 제거 특성에 관한 연구)

  • 박정호;전기일;정창훈
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1309-1313
    • /
    • 2003
  • This study was carried out to obtain the optimal ammonia removal efficiency using pyroligenous liquid for the economical and environment-friendly odor removal at a petty livestock farmhouse. The ammonia removal efficiencies were evaluated due to changing dilution rates(${\times}$10, ${\times}$20, ${\times}$30, ${\times}$50 and ${\times}$100 times) and different spray amounts(10$m\ell$ and 20$m\ell$) of pyroligenous liquid. The wet scrubber device was used to remove odor in closed-type livestock farmhouse. According to dilution rate of the pyroligenous liquid, the optimum rate was 20 times and the removal efficiency increased by decreasing dilution rates. In the case of spray amounts with the optimum dilution, the amount was 20 me and the removal efficiency increased by increasing spray amount. Also, the removal efficiency by using wet deodorizing device was 83.0-97.0% with 20 times diluted liquid.