• Title/Summary/Keyword: Odor removal

Search Result 233, Processing Time 0.023 seconds

Volatile organic compounds emitted from printing processes and their removal by adsorption (인쇄업에서 배출되는 반응성 VOCs 종류와 흡착 제거 방법의 적용)

  • Ahn, Hae Young;Lee, Yoon Kyoung;Song, Ji Hyeon
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.396-403
    • /
    • 2018
  • In this study, volatile organic compounds (VOCs) emitted from printing industries were analyzed, and an inorganic adsorbent, ${\gamma}-alumina$, was selected for the effective control of the VOC emissions. Printing processes commonly require inks, thinners, and cleaners, and they were mixed organic solvents containing aromatic compounds, ketones, and alcohols. Therefore, toluene, methyl ethyl ketone (MEK), and isopropyl alcohol (IPA) were selected as model compounds for this study. The adsorptive properties using ${\gamma}-alumina$ were determined for the model compounds. Both batch isotherm and continuous flow column tests demonstrated that the adsorption capacity of MEK and IPA was 3~4 times higher than that of toluene. The column test performed at an inlet toluene concentration of 100 ppm showed that an 80% breakthrough for toluene was observed after 3 hours, but both MEK and IPA were continuously adsorbed during the same time period. A numerical model simulated that the ${\gamma}-alumina$ could remove toluene at a loading rate of 0.4 mg/min only for a 4-hour period, which might be too short of a duration for real applications. Consequently, lifetime enhancement for ${\gamma}-alumina$ must be implemented, and ozone oxidation and regeneration would be feasible options.

A Development of Shoes Cleaner Control System using Raspberry Pi

  • Deukchang Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.7
    • /
    • pp.21-32
    • /
    • 2024
  • Since leather shoes cannot be washed with water, there is a need for a cleaning method that can remove extraneous substance from the inside and outside of shoes and senitize the inside of shoes without using water. For this purpose, this paper develops a shoes cleaning machine control system that automatically controls the entire process of shoes cleaning in a shoes cleaning machine that quickly cleans the inside and outside of shoes using compressed air, sterilization solution. The developed system uses Rasberry Pi, a general purpose single board computer(SBC), to control various actuators of the shoes cleaning machine. The shoes cleaning machine operated by the developed system shows a sterilization efficiency of more than 99% and an odor removal efficiency of more than 86% in a cleaning time of less than 1 minute.

Removal of VOCs and H2S from Waste Gas with Biotrickling Filter (생물살수여과법을 이용한 공기중 VOC 및 H2S 제거)

  • Kim, Kyoung-Ok;Kim, Yong-Je;Won, Yang-Soo
    • Applied Chemistry for Engineering
    • /
    • v.19 no.5
    • /
    • pp.519-525
    • /
    • 2008
  • Biodegradation of toluene, styrene and hydrogen sulfide as model compounds of volatile organic compounds and odor from waste gas was investigated experimentally in a biotrickling filter. This study focussed on the description of experimental results with regard to operating conditions. The effect of varying $H_2S$ load rate and inlet concentration was investigated under autotropic and mixotropic environmental conditions. The $H_2S$ removal efficiencies of greater than 99% were achieved at $H_2S$ loads below $10g/m^3{\cdot}hr$ for each environment. It was observed that the maximum elimination capacity of mixotrophic filter was achieved a little greater than the one of autotrophic filter. The biofiltration of toluene and styrene in trickling bed was examined under different gas flow rates, load rates, and inlet concentrations. Below $40g/m^3{\cdot}hr$ of toluene loading, the elimination capacity and loading were identical and it was completely destroyed. In high loading of toluene, the biotrickling filter was operated at its maximum elimination capacity. In the inlet concentration of 0.2, 0.5, and $1.0g/m^3$, the maximum elimination capacity of toluene showed 40, 45, and $60g/m^3{\cdot}hr$, respectively. After a short adaptation period, it was demonstrated that the results of styrene in originally toluene adapted bioreactor was similar with the ones of toluene. However, the performance of filer for styrene is generally a little lower than for toluene. The operating conditions (including liquid flow rate etc.) allowing the highest removal efficiency should be determined experimentally for each specific case.

Removal Efficiency of Water Pollutants and Malodor of Pig Slurry using Biofiltration System (여재순환장치를 이용한 돈분뇨 슬러리의 오염물질 및 악취제거 효율)

  • Choi, D.Y.;Kwag, J.H.;Jeong, K.H.;Park, K.H.;Huh, M.Y.;Kim, J.H.;Kang, H.S.;Jeon, K.H.;Park, C.H.;Jeong, J.W.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.3
    • /
    • pp.217-224
    • /
    • 2009
  • The pig slurry is one of important fertilizer source for production of crops in recent years, but it has many controversial points of utilization such as offensive odor, lack of spread equipment and farmland possession, respectively. This study was carried out in order to remove water pollutants and malodor of pig slurry using biofiltration system. The biofiltration system consists of pig slurry separator, mixing shift and attached blade for sawdust or ricehull, air injection nozzle and outlet for pig slurry and sawdust or ricehull. The characteristics pH, $BOD_5$ (Biochemical Oxygen Demand), $COD_{Mn}$ (Chemical Oxygen Demand), SS (Suspended Solid), T-N (Total Nitrogen), T-P (Total Phosphorus) of the untreated pig slurry used in this study were 7.2, 34,450, 24,604, 71,000, 4,194, $1,631\;ml/{\ell}$, respectively. The $NH_3$ (Ammonia) and $H_2S$(Hydrogen Sulfide) concentration were 70.0, 9.6 ppm, respectively. The initial total microorganisms of pig slurry were $5.0{\times}10^3\;cfu/ml$, and Salmonella, Bacillus were $5.8{\times}10^2$, $1.1{\times}10^3\;cfu/ml$, respectively. The filtration system was very effective on removal of water pollutants of pig slurry. The removal efficiency of the offensive odor of ammonia and hydrogen sulfide in sawdust was higher than those of ricehull. The total microorganisms and bacillus of pig slurry are on the increase by sawdust and ricehull, but Salmonella showed a tendency to decrease in number after that time. Accordingly, the filtration system was very effective to produce a good quality pig slurry.

  • PDF

Hot Water Extraction of Crude Chondroitin Sulfate from Shark Cartilage Treated with Ozone Water (오존수로 세척한 상어연골로부터 Crude Chondroitin Sulfate의 열수추출)

  • Jung, Yoo-Kyung;Shin, Kyung-Ok;Shin, Jong-Wook;No, Hong-Kyoon;Kim, Soon-Dong
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.2 no.3
    • /
    • pp.149-154
    • /
    • 2007
  • This study was conducted to investigate the effect of ozone treatment on removal of brown color and ammonia-like odor produced from shark cartilage (SC) and to establish the optimal extraction conditions of chondroitin sulfate (CS) by NaOH and hot water. Treatment of SC with 0.3 ppm ozone water resulted in higher color $L^*$ value but lower $a^*$ and $b^*$ values compared with those of non-treated SC, without affecting its proximate compositions (moisture, protein, lipid, carbohydrate, and ash). Ozone treatment also increased the overall acceptability of SC by reducing ammonia-like odor. The optimum concentration and time for extraction of CS from SC using NaOH at $100^{\circ}C$ were 1 N and 120 min, respectively, with 10.02% of extraction yield. The total yield (10.01%) of CS obtained by 7 times repeated extraction with hot water at $100^{\circ}C$ was comparable to that of the 1 N NaOH extraction for 120 min at $100^{\circ}C$.

  • PDF

Removal of Mixed Odor(H$_2$S/CH$_3$SH) using Char Adsorbent Made from Sewage Sludge (하수슬러지 탄화물 흡착제를 이용한 혼합 악취(H$_2$S/CH$_3$SH)의 제거)

  • Han, Young-Suk;Choi, Won-Joon;Kim, Taek-Joon;Kim, Im-Gyung;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1132-1138
    • /
    • 2008
  • The study was carried out to investigate adsorption characteristic on hydrogen sulfide (H$_2$S) and methylmercaptan (CH$_3$SH) odor gas using the char made by a thermal decomposition of sewage sludge. The fixed bed adsorption experiments of the optimum L/D ratio could be 1.0, and adsorption capacity and break point increased with the increase of temperature. A simultaneous adsorption characteristic of H$_2$S and CH$_3$SH increased in breakthrough time and adsorption capacity more than single adsorption experiment, and CH$_3$SH had higher effective diffusivities than H$_2$S in same condition. The adsorption capacity of CH$_3$SH increased with fast velocity. When it was compared the produced absorbent with commercial activated carbon, As to adsorbent amount, it was H$_2$S 77% and CH$_3$SH 80% of commercial activated carbon.

Effect of fermented earthworm cast feed on the production of high-quality eggs and odor reduction (지렁이 분변토 발효사료가 고품질 계란생산 및 악취 저감에 미치는 영향)

  • Shin, Jong-Suh;Yang, Boo-Keun;Park, Byung-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.577-586
    • /
    • 2017
  • The aim of this study was to investigate the effects of fermented earthworm cast feed prepared with three complexed probiotics containing Bacillus subtilis separated from the earthworm casts, on egg production, egg quality and odor removal from poultry house. A total of 240 laying hens were divided into 4 treatments and completely randomized. Experimental groups were divided into control, 0.3 to 0.5% (fermented earthworm cast feed FECF3, FECF5) and 0.2% commercial probiotics (CP). The egg production rate was significantly higher in the FECF groups compared to the control group fed the normal feed, but there was no difference in the CP group. Haugh units, egg shell thickness, breaking strength, egg yolk index and albumen height were increased in FECF groups compared to control but not in CP group. The n-3 content of eggs was higher in the FECF groups than in the control group, while the n-6/n-3 ratio was lower and there was no difference from the CP group. Ammonia production was lower in the CP and FECF groups compared to the control group after 5 days storage at room temperature to poultry feces.

Use of Hydrogen Peroxide with Ozone to Simultaneously Reduce MIB and Quench Ozone Residual in Existing Water Treatment Plants Sourcing Water from the Han River (한강을 원수로 하는 오존/과산화수소 고도정수처리공정에서의 MIB제거 및 잔류오존 농도에 관한 연구)

  • McAdams, Stephen R.;Koo, Bon Jin;Jang, Myung Hoon;Lee, Sung Kyoo
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.704-716
    • /
    • 2012
  • This paper provides a detailed account of pilot testing conducted at South Lake Tahoe (California), the Ddukdo (Seoul) water treatment plant (WTP) and the Bokjung (Seongnam) WTP between February, 2010, and February, 2012. The objectives were first, to characterize the reactions of ozone with hydrogen peroxide (Peroxone) for Han River water following sand filtration, second to determine empirical ozone and hydrogen peroxide doses to remove a taste-and-odor surrogate 2-methylisoborneol (MIB) using an advanced oxidation process (AOP) configuration and third, to determine the optimum dosing configuration to reduce residual ozone to a safe level at the exit of the process. The testing was performed in a real-time plant environment at both low- and high seasonal water temperatures. Experimental results including ozone decomposition rates were dependent on temperature and pH, consistent with data reported by other researchers. MIB in post-sand-filtration water was spiked to 40-50 ng/L, and in all cases, it was reduced to below the specified target level (7 ng/liter) and typically non-detect (ND). It was demonstrated that Peroxone could achieve both MIB removal and low effluent ozone residual at ozone+hydrogen peroxide doses less than those for ozone alone. An empirical predictive model, suitable for use by design engineers and operating personnel and for incorporation in plant control systems was developed. Due to a significant reduction in the ozone reaction/decomposition at low winter temperatures, results demonstrate the hydrogen peroxide can be "pre-conditioned" in order to increase initial reaction rates and achieve lower ozone residuals. Results also indicate the method, location and composition of hydrogen peroxide injection is critical to successful implementation of Peroxone without using excessive chemicals or degrading performance.

Technical and Economical Assessment of Adsorption and Reverse Osmosis for Removal of Ammonia from Groundwater of Kathmandu, Nepal (네팔 카트만두 지하수에서 암모늄 제거를 위한 이온 교환 및 역삼투의 기술 및 경제 평가)

  • Kunwar, Pallavi;Ahn, Jaewuk;Baek, Youngbin;Yoon, Jeyong
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.174-182
    • /
    • 2020
  • The permissible limit of ammonia concentration in drinking water recommended by the World Health Organization (WHO) is 1.5 mg/L. However, in the case of groundwater in Kathmandu, Nepal, the concentration of ammonia fluctuates dramatically from 0 to 120 mg/L at different locations and groundwater depths (Chapagain et al., 2010). Such a high concentration of ammonia causes aesthetic problems in drinking water, such as bad taste and odor; hence, prior treatment is required. In Kathmandu, half of the population utilizes groundwater, which is also employed for drinking water, but owing to a lack of knowledge of household water filters, residents of Kathmandu tend to depend greatly on commercially available jar water than on the installation of a proper household filtration method. Thus, in our study, we employed adsorption and reverse osmosis (RO) as two of the most viable decentralized/household treatment options to address the issue of high contamination of ammonia in drinking water. We evaluated their performances from technical and the economic perspectives using synthetically prepared groundwater at varying ammonia concentrations (50 mg/L and 15 mg/L). Consequently, it was found that adsorption via ion exchange (IE) resin was a comparatively better ammonia removal technology than RO, with 100% ammonia removal even after regeneration; the removal by RO was limited to up to 90%. Furthermore, our study suggests that IE is the most suitable ammonia removal technology for places with lower water consumption (< 50 L/day), whereas RO seemed to be a cost-effective technology for places with higher water consumption, where the daily water demand exceeds 50 L/day. Lastly, these assessments suggest that installing a suitable household treatment system would be more efficient and sustainable from both technical and economic points of view than purchasing commercially bottled water.

Oxidation of Geosmin and 2-MIB in Water Using $O_3/H_2O_2$: Kinetic Evaluation (오존과 과산화수소를 이용한 Geosmin과 2-MIB 산화: 동력학적 평가)

  • Lee, Hwa-Ja;Son, Hee-Jong;Roh, Jae-Soon;Lee, Sang-Won;Ji, Ki-Won;Yoo, Pyung-Jong;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.826-832
    • /
    • 2007
  • Unpleasant tastes and odors in drinking water cause same problems for water utilities across Korea. Even though tastes and odors do not create health problems, they are main concerns for consumers who determine the safety of their drinking water. In this study, two different odor producing compounds(geosmin 2-MIB) in the Nakdong river water and rapid sand filtered rater were treated by advanced oxidation of $O_3/H_2O_2$ process. The experimental results showed that the removal efficiency of geosmin with the use of 5 mg/L of $O_3$ and $H_2O_2$ was higher than efficiency with the use of $O_3$ alone for both the raw water and the sand filtered water. And in general, the removal efficiency of geosmin was higher than 2-MIB in the sand filtered water. Under the range of $O_3$ concentration $0.5\sim2.0$ mg/L, the removal rate constants(k) of geosmin for the raw and sand filtered waters, and the one of 2-MIB in the sand filtered water were increased rapidly as doses of $O_3$, and $H_2O_2$, increased. The removal rate constants(k) do not increase any more when $H_2O_2/O_3$ ratio increases above the optimum ratio. The optimum ratio of $H_2O_2/O_3$, dose was $1.0\sim2.0$ for both geosmin and 2-MIB. The removal rate constant(k) becomes lower when OH radical consuming materials are present in raw water. The half-life of geosmin decreased rapidly as the $O_3$ and $H_2O_2$ doses increase in the sand filtered water. The half life decreased about 8.5 times with the use of 2 mg/L of $O_3$ and 10 mg/L of $H_2O_2$ than with the use of 2 mg/L of $O_3$ alone for the sand filtered water.