• Title/Summary/Keyword: Odor

Search Result 1,902, Processing Time 0.03 seconds

Studies on Flavor Components and Organoleptic Properties in Roasted Red Ginseng Marc (볶음처리한 홍삼박의 향기성분과 관능적 특성)

  • Park Myung-Han;Sohn Hyun-Joo;Jeon Byeong-Seon;Kim Na-Mi;Park Chae-Kyu;Kim An-Kyun;Kim Kyo-Chang
    • Journal of Ginseng Research
    • /
    • v.23 no.4
    • /
    • pp.211-216
    • /
    • 1999
  • The red ginseng marc was roasted at various conditions and its organo-leptic properties and flavor components were investigated. Scorched-rice odor and roasted odor and the roasted red ginseng marc powder were much stronger than those from the unroasted red ginseng marc powder while earth odor, old-rice odor, metalic off-odor and woody odor were much weaker than those from the unroasted red ginseng marc. Savory odor and scorched-rice odor as well as savory taste and astringent taste from the water-extract of red ginseng marc roasted at $200^{\circ}C$ were stronger, but smoky odor, woody odor, biner taste and rough taste were weaker than those roasted at $230^{\circ}C$. Seven kinds of pyrazines, two kinds of carbonyl compounds, seven kinds of acids, two kinds of esters, five kinds of phenolic compowlds, maltol and six other compounds were identified as flavor components in distillate from red ginseng marc roasted at $200^{\circ}C$ for twenty minuties. Of them pyrazines and maltol are thought to be compounds which have characteristic odor such as roasted odor and/or scorchedrice odor in the roasted red ginseng marc.

  • PDF

A Study on Separation Distance between Industrial Source and Residential Areas to Avoid Odor Annoyance Using AUSPLUME Model (AUSPLUME 모델을 이용한 악취를 피하기 위한 산업오염원과 주거단지 사이 이격거리에 관한 연구)

  • 정상진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.393-400
    • /
    • 2002
  • Separation distance between industrial source and residential areas to avoid odor annoyance was investigated using AUSPLUME model. A Gaussian plume model (AUSPLUME) for the dispersion was used to calculate odor emission from ground level area source. Using the dispersion model to calculate ambient odor concentrations, the separation distance between industrial source and residental areas was defined by %HA (percentage of highly annoyed person) and odor percentile concentration (C98). The result was compared with the separation distance of various nation guidelines for livestock buildings. The calculated separation distance for industrial source showed similar pattern comparing with various guidelines for livestock buildings.

Measurement of odor compounds from odorous emissions source of Industrial Complex (산업단지에서 배출되는 악취원인물질의 규명)

  • An Sang-Young;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.81-89
    • /
    • 2005
  • As a typical example of simultaneous analysis of the odorous compounds, the volatile organic compounds from inventory sources in Seongseo industrial area were concentrated and analyzed with thermal desorber/GC/MSD, and major malodorous compounds were estimated. Odor intensity and odor concentration was analyzed simultaneously During a period from November in 2002 to December in 2003, this study was conducted to evaluate malodor emission characterization in major treatment facilities. The major components were Dimethyl sulfide, Dimethyl disulfide, Methyl mercaptane, Ammonia, Benzene, Toluene, m,p-xylene, o-xylene, Styrene, 1,2,4­T.M.B and 1,3,5-T.M.B. Among the six major inventory sources, the odor unit concentration of Night-soil disposal facilities was the highest, $669\~2344\;ou/m^{3}.$

Odor Reduction Technology in Sewage Treatment Facility Using Biofilter with Reed Grass(Phragmites australls) (갈대(Phragmites australls)수초를 적용한 바이오필터에서의 하수처리시설 악취저감기술)

  • Chung, Jin-Do;Kim, Kyu-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.373-382
    • /
    • 2013
  • In this study, a biological odor treatment system was proposed to remove odor(foul smell) materials causing several problems in the closed sewage treatment plant. This odor treatment system was composed of a two-step biofilter system in one reactor. The two-step biofilter reactor was constructed with natural purification layer in upper part and artificial purification layer in lower part. The reed grasses of water purification plants were planted in the surface area and mixed porous ceramic media were filled with the lower part of biofilter reactor. By using the above experimental apparatus, the ammonia gas removal efficiency was attained to 98.3 % and the hydrogen sulfide gas removal efficiency was appeared more than 97.7 % which shows more effective than the conventional odor removal process.

Analysis of the Compounds of Unpleasant Odor from the Cotton Fabrics through Different Washing Conditions (세탁조건에 따른 면직물 중의 악취성분 분석)

  • 박명자;최해운
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.5
    • /
    • pp.555-564
    • /
    • 2002
  • The purpose of this research was to analysis compounds of unpleasant odor from the cotton fabrics in dehydration and drying process during washing. The cotton fabrics were treated with various commercial detergents and fabric softener or cationic surfactants such as Cetyltrimethylammonium bromide(CTAB) and Benzalkonium chloride(BC), then dehydrated and dried. The compounds of odor impregnated in fabric were detected by using CC-MS. The results are as follows: The fabrics treated with a powder-type detergent, CTAB and BC gave out compounds unpleasant odor. n-Butyraldehyde and isobutyaldehyde produced during microorganism growth were revealed as source of the compounds of the unpleasant odor. However, no aldehydes were detected from the fabrics treated with commercial fabric softener which seems to act as a deodorizer.

  • PDF

A Study on Odor Removal of Landfill Site Leachate by Pyroligenous Liquid (목초액을 이용한 쓰레기 매립지 침출수의 악취 제거에 관한 연구)

  • 허광선;정의덕;백우현
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.607-610
    • /
    • 1999
  • The odor removal of landfill site leachate was carried out using pyroligenous liquid. The constituent elements of pyroligenous liquid and leachate were also analysed, employing Atomic Absorption Spectroscopy(AAS). Before order removal, the heavy metal ions such as Pb, Zn, Cu, Mn, Fe and Ni, in pyroligenous liquid were detected with ultra trace level. However, in this liquid, other metal ions such as As, Hg and Cd were not observed. The optimum condition for removing odor fromthe leachate was observed in 15 times dilution of pyroligenous liquid. Also, the degree of outlet odor was 1. Furthermore, the concentration of odor constituent compounds, e.g. $H_2S, NH_3, NH_2$ and $CO_2$ in the leachate was remarkably reduced. Finally, water quality of the leachate was improved.

  • PDF

The Relationship Between Odor Unit and Odorous Compounds in Control Areas Using Multiple Regression Analysis (다중회귀분석을 이용한 악취 관리지역에서의 복합취기강도와 개별악취물질들의 관계에 대한 연구)

  • Kim, Jong-Bo;Jeong, Sang-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that $NH_3$ and styrene concentrations in SIC and BPIC were relatively higher and $H_2S$ concentration especially in mc was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of $H_2S$, TMA, styrene and n-valeraldehyde in SIC, $H_2S$, acetaldehyde, and butyraldehyde in BPIC and $NH_3$ in BIC.

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.3
    • /
    • pp.1-9
    • /
    • 2021
  • Purpose: This study was conducted to develop a module with higher removal efficiency and effectiveness by adapting two or more deodorization techniques for main cause of odor pollution exposed citizen living near water treatment facilities. Research design, data and methodology: To consider the standard, unity, electrical wire, compatibility of detachable device by installing two types of dry deodorization device within one module for easy replacement. Complex odor, H2S, NH3 were collected from sewage treatment facilities for evaluation of deodorization device. Results: Using the developed application in this study, removal efficiency of complex odor, H2S, NH3 were 93%, 100%, 82%, respectively. Conclusions: The H2S removal efficiency of deodorization device was higher than bio-filter system, which were currently used by sewage treatment. Further, the device should be considered for use in efficient odor removal system.

Odor Emission from Sediments in Sewer Systems and Odor Removal using an Electrolytic Oxidation Process (하수관거에 퇴적된 유기물에 의한 악취 발생과 산화전리시스템을 이용한 악취 저감)

  • Ahn, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.703-710
    • /
    • 2011
  • Odor emission from domestic sewer systems has become a serious environmental problem. An investigation on a sewer manhole revealed that anaerobic decay of sediment organic matters (SOMs) and related declines of oxidation reduction potential (ORP) in the sediment layer were the main reason of the production of volatile sulfur compounds. In addition, as the anaerobic decaying period continued, the odor intensity rapidly increased with increasing concentrations of $H_2S$ and dimethyl sulfide. As a feasible method to control SOMs and to minimize odor emission potentials, an electrolytic oxidation process has been employed to the sediment sludge phase. In this study, voltages applied to the electrolytic oxidation process were varied as a main system parameter, and its effects on odor removal efficiencies and reaction characteristics were investigated. At the applied voltages greater than 20 V, the system efficiently oxidized the organic matter, and the ORP in the sludge phase increased rapidly. As a consequence, the removal efficiency of hydrogen sulfide was found to be >99% within 60 minutes of the electrolytic oxidation. Overall, the electrolytic oxidation process can be an alternative to control odor emission from sewer systems, and a threshold input energy needs to be determined to achieve effective operation of the process.

Odor emission characteristics in anaerobic high temperature burial composting of swine carcasses (돼지 사체의 혐기적 고온 매몰퇴비화법에서의 악취발생 특성)

  • Yang, Woo-Young;Lee, Jin-Young;Choi, Yeon-Ju;Ryu, Hee-Wook;Chae, Jeong-Seok;Jeon, Jun-Min
    • Journal of odor and indoor environment
    • /
    • v.16 no.2
    • /
    • pp.187-198
    • /
    • 2017
  • It is very important to treat infected livestock carcasses safely and quickly. In this study, the degradation characteristics and odor generation characteristics of carcasses were investigated during the treatment of swine carcasses using the anaerobic burial composting method. While the carcasses were decomposed, the temperature remained high, at $40{\sim}55^{\circ}C$ on average, and most of the carcasses were decomposed rapidly. The major odor-contributing substances in the buried composting method are sulfuric odor substances such as $H_2S$, $CH_3SH$, dimethyl sulfide (DMS) and dimethyl disulfide (DMDS), and the odor contribution of these substances is 93~99%. Among them, $CH_3SH$, which accounts for about 56~89% of odor contribution, was the most representative indicator substance. Despite the anaerobic digestion process, the methane concentration in the digestion process was as low as 0.5~0.8% at the burial point of the carcass. The odor and methane produced during the decomposition of the carcasses decreased considerably during the discharge to the surface layer through the buried layer consisting of compost. These results suggest that anaerobic high temperature burial composting is one of the most useful methods to treat carcasses of infected livestock.