• Title/Summary/Keyword: Octanol-air partitioning coefficient

Search Result 11, Processing Time 0.022 seconds

Gas-particle Partitioning of Organochlorine Pesticides in Atmosphere (대기 중 유기염소계 살충제의 가스-입자 분배)

  • Choi, Min-Kyu;Chun, Man-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.457-465
    • /
    • 2007
  • This study was performed to estimate the gas-particle partitioning of organochlorine pesticides (OCPs) in atmosphere, the samples were collected by PUF high volume air sampler for two years from June, 2000 to June, 2002. The gas phase fraction of ${\alpha/\gamma}-HCH$, heptachlor epoxide, ${\alpha/\gamma}-chlordane$ and trans-nonachlor was over 90%. But the gas phase fraction of ${\beta}-HCH$, p,p'-DDE, endosulfan sulfate, p,p'-DDD and p,p'-DDT was range of 20% through 80%, which means the gas phase fraction of OCPs components described above is sensitive to temperature. The correlation between the gas phase fraction and molecular weight of each OCPs component was not found in this research. The slope of regression line between gas-particle partitioning coefficient(${\log}K_p$) and subcooled liquid vapor(${\log}{P^o}_L$), gal-particle partitioning coefficient(${\log}K_p$) and octanol-air partitioning coefficient(${\log}K_{oa}$) which show -0.54 and 0.43 was not steep. So the equilibrium state between gas and particle was not reached and in this state the particulate fraction was low.

Characteristic Factors of Air-Plant Partitioning of PCBs (PCBs의 대기-식물간 분배 특성 인자들)

  • 여현구;최민규;천만영;김태욱;선우영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.5
    • /
    • pp.415-424
    • /
    • 2001
  • The concentrations of PCBs (polychlorinated biphenyls) in air and plants (MOrus allba, Allum turberosum) were measured every other week at Hankyong University located in Ansung, Kyoung-ki province, Korea from July to November in 1999. Total concentrations of PCBs in air ranged from 19.8 to 71.9 pg/ $m^3$. It was observed in air that the concentrations of tai-chlorinated biphenyls(CBs) were higher than those of other PCB homologs probably due to their higher vapor pressure. Total concentrations of PCBs in plants ranged from 24.5 to 1,287 pg/g dry weight for Morus allba and 26.5 to 337 pg/g dry weight for Allum turberosum. A positive linear correlation was observed between log plant-air partition coefficients ( $m^3$air/g plant dry weight-defined here as the scavenging coefficient[S.C]) and log octanol-air partition coefficients ( $K_{oa}$ ) for each plant. In this study, slope of log S.C and log $K_{oa}$ for Morus allba, Allum turberosum were 1.07 ($R^2$= 0.83, p<0.01), 0.84 ($R^2$=0.53, p<0.05), respectively. This means that these plants may approach to equilibrium for air-plant partitioning.

  • PDF

Air-Soil Partitioning of PCBs in Rural Area

  • Yeo, Hyun-Gu;Park, Min-Kyu;Chun, Man-Young;Young, Sun-Woo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E1
    • /
    • pp.1-9
    • /
    • 2003
  • The soil concentrations of polychlorinated biphenyls (PCBs) were measured at 12 sites in Ansung, Kyonggi province, Korea. Correlation coefficient (r) between total PCBs and organic matter content (OM) was significant (r=0.562, p< 0.05). It suggests that organic matter may be a key factor of soil absorption of PCBs. The PCB concentrations of low chlorinated congeners with high vapor pressure were relatively abundant in air but high chlorinated congeners with low vapor pressure were mainly dominated by soil. The results indicated the influence of physicochemical properties of PCBs such as vapor pressure, octanol - air partition coefficient ( $K_{OA}$ ). The calculated soil/air fugacity quotients suggested that the soil may be a source of heavier molecular PCBs (>penta-CBs) to the atmosphere, where lighter molecular PCBs appear to be affected by a movement from air to soil, especially tetra-CBs. Therefore, PCB homologs with low vapor pressure might have been influenced by revolatilization from soil.

Organic Pollutant Transport in Unsaturated Porous Media by Atmospheric Breathing Processes( I ) - Partition Coefficient -

  • Ja-Kong;Lim, Jae-Shin;Do, Nam-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1996.11a
    • /
    • pp.50-53
    • /
    • 1996
  • This paper reports the experimental results for the determination of the overall partition coefficient of VOCs in unsaturated soil, A chromatographic method was used for the determination of gaseous partition coefficients to natural soil under various water content conditions. The equilibrium vapor pressure of water over saturated salt solution was used to fix the relative humidity of the air and control the water content of the soil systems. The transport behavior was studied for dichloromethane, trichloroethane and dichlorobenzene pollutants, with log octanol-water partition coefficients(log $K_{ow}$ ) which range from 1.25 to 3.39, or water to soil partitioning which varies by 135 times; water solubility constants which vary by 3 times; and vapor pressures which range from 1 to 362 torr. Water content of the soil had a pronounced effect on the effective partition coefficient(between gas and soil + water stationary phase) as well as on the effective dispersion coefficient.

  • PDF

Variation of Atmospheric Concentrations of Organochlorine Pesticides (OCPs) and Polychlorinated Biphenyls (PCBs) at Different Height (대기 중 유기염소계 살충제(OCPs)와 PCBs의 높이별 농도 변화)

  • Chun, Man-Young;Choi, Min-Kyu;Yeo, Hyun-Gu
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.3
    • /
    • pp.201-211
    • /
    • 2008
  • This study was performed to find the atmospheric concentrations of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) at four different heights (l0, 50, 150 and 1,500 cm) using low volume polyurethane foam (PUF) plug air sampler in semi-rural area. ${\alpha}-/{\beta}-/{\gamma}-HCH$ with low molecular weights and Koa (octanol-air partitioning coefficient) in OCPs were similarly high concentrations at all heights, but the other OCPs (p,p'-DDE, p,p'-DDD, p,p'-DDT, Heptachlor epoxide, ${\gamma}$-CHL, ${\alpha}$-CHL, Trans-nonachlor) with high molecular weights and Koa decreased with increasing heights. However, the concentrations of PCBs increased with increasing height.

Estimation of PCDD/Fs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무 잎을 PAS로 이용하여 대기 중 PCDD/Fs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.116-125
    • /
    • 2015
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) for atmospheric polychlorinared dibenzo-p-dioxins/furans (PCDD/Fs). Methods: PCDD/Fs concentrations in ambient air ($C_a$, $pg/m^3$) and deposited pine needles ($C_p$, pg/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using two low volume PUF active air samplers with an overall average air volume of approximately $1,200Sm^3$. Pine needles were collected the end of December near the air sampler. PCDD/Fs was analyzed by HRGC/HRMs. Results: A good correlation was shown ($R^2=0.6357$, p=0.0001) between $C_a$ and $C_p$, but a better correlation ($R^2=0.7372$, p<0.0001) existed between the logarithm of octanol-air partitioning coefficient ($LogK_{oa}$) and Log($C_p/C_a$). The average PCDD/Fs sampling rates from air to pine needles were 0.045($0.018-0.185m^3/day-g\;dry$). Conclusion: It was found that pine needles can be used as PAS for atmospheric PCDD/Fs, and they are especially suitable for long time PAS compared to PUF disk PAS.

Relationship between PAHs Concentrations in Ambient Air and Deposited on Pine Needles

  • Chun, Man-Young
    • Environmental Analysis Health and Toxicology
    • /
    • v.26
    • /
    • pp.4.1-4.6
    • /
    • 2011
  • Objectives: This study was carried out to determine whether or not pine needles can be used as passive samplers of atmospheric polycyclic aromatic hydrocarbons (PAHs) using the correlation between accumulated PAH concentrations in air (Ca, ng/$m^3$) and those deposited on pine needles (Cp, ng/g dry). Methods: PAHs in ambient air was collected using low volume PUF sampler and pine needles was gathered at same place for 7 months. Results: A good correlation ($R^2$=0.8582, p<0.05) was found between Ca and Cp for PAHs with a higher gaseous state in air (AcPy, Acp, Flu, Phen, Ant, Flt, Pyr, BaA and Chry), but there was a poorer correlation ($R^2$=0.1491, p=0.5123) for the PAHs with a lower gaseous state (BbF, BkF, BaP, DahA, BghiP and Ind123). A positive correlation ($R^2$=0.8542) was revealed between the logarithm of the octanol-air partitioning coefficient ($logK_{oa}$) and Cp/Ca for the PAHs with a higher gaseous state in air, but there was a negative correlation ($R^2$=0.8131) for the PAHs with a lower gaseous state. The Ca-Cp model could not be used to estimate PAHs concentrations in air using deposited PAHs concentrations on pine needles, but the logKoa-Cp/Ca model could be used. Conclusions: It was found that pine needles can be used as passive samplers of atmospheric PAHs.

Annual Variation and Gas/Particie Partitioning of PCDD/DFs of Ambient Air at Busan, Korea (부산의 대기 중 PCDD/DFs의 연간 변화와 가스/입자상 분배)

  • Ok, Gon;Park, No-Jin;Hwang, Sung-Min;Lee, Seok-Hyung;Kim, Jee-Hoon;Kim, Sung-Yong
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.447-457
    • /
    • 2010
  • This study aims to monitor the variation of concentration of PCDD/DFs between the gaseous phase-particulate phases in the ambient air of urban area in Korea. This monitoring is evaluated by using the Junge-Pankow model and the Koa absorption model with the application of the Octanol-air partition coefficient. In this study, the ambient air samples were analyzed according to each congener group of the PCDD/DFs by HRGC/HRMS, which have been investigated for the past 5 years. In the results, the annual variation in the concentration level of $\Sigma$PCDD/DFs in TSP was increased from $1588\;fg/m^3$ in 1998 to $5123\;fg/m^3$ in 2002, and from 31 fg I-TEQ/$m^3$ to 94 fg I-TEQ/$m^3$ in the $\Sigma$I-TEQ. In the case of PUF of gaseous phase sample, their variation was increased from $1615\;fg/m^3$ in 1998 to $2237\;fg/m^3$ in 2002, and in the $\Sigma$I-TEQ from 12 fg I-TEQ/$m^3$ to 17 fg I-TEQ/$m^3$. The relative coefficient between the gas phase concentration of PCDD/DFs and the temperature was a value of 0.744; the contributive rate of the temperature to the gaseous phase concentration was 0.554. According to the results, the pattern of the coefficient of distribution based on log $p_L^0$ is similar to the ambient air of the urban areas.

Estimation of PCBs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무잎을 Passive Air Sampler(PAS)로 이용하여 대기 중 PCBs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.360-368
    • /
    • 2012
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) of atmospheric Polychlorinated Biphenyls (PCBs). Methods: PCB concentrations in ambient air ($C_a$, ng/$m^3$) and deposited on pine needles ($C_p$, ng/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using a low volume PUF active air sampler and the overall average air volume was about 900-1,000 $m^3$. Pine needles were collected at the end of August and December near the air sampler. Results: $C_a$ were higher at higher air temperature and lower chlorinated PCB congeners, but $C_p$ showed irregular distribution. The average PCB sampling rates from air to pine needles were 0.116 (0.002-0.389) $m^3$/day - g dry. Conclusions: A poor correlation was shown between $C_a$ and $C_p$. However, a good correlation was shown between the logarithm of octanol-air partitioning coefficient ($logK_{oa}$) and log ($C_p/C_a$), and the interrelation was better with longer sampling time (June to December) than shorter sampling time (June to August). The average PCB sampling rates from air to pine needles were the lowest with respect to PUF disk, XAD-2 resin and semipermeable membrane devices (SPMDs) PAS. The average ratio ($C_{a-calc}/C_{a-meas}$) of calculated ($C_{a-calc}$) and measured ($C_{a-meas}$) PCB concentration was 0.69 with a shorter sampling time and 1.24 with a longer, so $C_{a-calc}$ was close to $C_{a-meas}$. It was found that pine needles can be used as PAS of atmospheric PCBs, and are especially suitable for long-time PAS.

Concentration Characteristics of PCBs in Pine Needle and Soil at Rural Area (교외지역에서 소나무 잎과 토양 중 PCBs의 농도 특성)

  • Shin Eun-Sang;Yeo Hyun-Gu
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.1-11
    • /
    • 2006
  • This study was to investigate concentration characteristics of atmospheric PCBs in soil sample and pine needle at rural area. Profiles of PCB congener detected in pine needle and soil sample have a difference that low molecular PCBs mainly existed in pine needle, whereas high molecular PCBs were mainly existed in soil sample because of their different vapor pressure and octanol-air partitioning coefficient($K_{OA}$) of each congeners. Correlation coefficients(r) of PCB congeners simultaneously detected in soil and pine needle were significant (r>0.71, p<0.01), which showed that PCB congeners patterns of atmosphere could be estimated in using pine needle and soil sample indirectly. The contributions(%) of higher molecular PCBs(>penta-CB) to total PCBs in soil sample were higher than those of pine needle and the contribution of lower molecular PCBs(