• Title/Summary/Keyword: Occlusion type

Search Result 291, Processing Time 0.037 seconds

3D FINITE ELEMENT ANALYSIS OF OVERDENTURE STABILITY AND STRESS DISTRIBUTION ON MANDIBULAR IMPLANT-RETAINED OVERDENTURE (하악 임플랜트 유지형 피개의치의 안정성과 하악골 응력분포에 대한 3차원 유한요소법적 연구)

  • Hong, Hae-Ryong;Choi, Dae-Gyun;Bak, Jin;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.633-643
    • /
    • 2007
  • Statement of problem: Recently there are on an increasing trend of using implants-especially in edentulous mandible of severly alveolar bone recessed. Purpose: The aim of this study was to analyze the displacement and stress distribution of various mandibular implant-retained overdenture models supported by two implants in interforaminal region under the occlusion scheme load. Material and method: FEA models were made by the 3D scanning of the edentulous mandibular dentiform. The three models were named as Model M1, M2, and M3 accord ing to the position of implants: M1, Lt. incisor area, M2, Canine area, and M3, 1st Premolar area. Inter-implant angulation model was named as M4. Conventional complete denture was named M5 and used as a control group. Ball implant and Gold matrice were used as a retentive anchors. The occlusion type loads were applied horizontally over each tooth. Results: 1. In mandibular implant retained overdenture Canine Protected Occlusion type load resulted in higher levels of stress to the implants and female matrices than other types of loads. 2. The overdenture model M1, with implants in lateral incisor areas resulted in lower stress concentration to the implants and female matrices than other models. 3. In mandibular implant retained overdenture the stresses of the implant and female matrice were lower in mesially inclined implant than these of parallel installed implant. Conclusion: Lateral incisor areas could be the best site for the implants in mandibular implant-retained overdenture. The mandibular implant retained overdenture models mentioned above showed to the lowest stress to the implants and female matrices.

A Longitudinal change of ODI and APDI on Three Facial Growth Patterns in Koreans with Normal Occlusion (정상 교합자의 세가지 안면 성장유형에 따른 ODI, APDI의 변화)

  • Lee, Sun-Reong;Park, Kyung-duk;Kyung, Hee-Moon;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.557-568
    • /
    • 1996
  • The purpose of this study was to analyze the growth changes of ODI and APDI with age on the three facial growth patterns. The biennial serial cephalometric radiographs of 19 male and 14 famale samples with normal occlusion during 10 years were used in this study. The samples were divided into three groups - drop type, neutral type, forward type - by the total change of the Y-axis during the periods of the study. The findings in this investigation indicated the following: 1. The mean values and standard deviations of each age group in each facial type of male and famale were obtained. 2. The difference of ODI and APDI among the 3 facial types was not significant through all observed ages(P)0.05). The size of ODI appeared large consistently in order of the drop, neutral, and forward type in both male and female through all observed ages. 3. The ODI and APDI were maintained without any charges with age during the periods of the study(p>0.05). 4. In correlation analysis between the total change of the Y-axis and 6 measurements, the AB plane angle and facial angle showed correlation in both male and female(p<0.05), the APDl in only female(p<0.001), but the ODI not appeared correlation in either male or female(p>0.05).

  • PDF

PHOTOELASTIC ANALYSIS OF MANDIBULAR STRESSES INDUCED BY LINGUALIZED OCCLUSION (Lingualized Occlusion에 의한 하악응력의 광탄성학적 분석)

  • Kim, Sang-Soo;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.153-169
    • /
    • 1988
  • There is a little scientific documentation reporting the stress, distribution to the edentulous mandible by different concepts of occlusal scheme. So, this study was to investigate the hypothesis that the magnitude and distribution of the occlusal stresses, transmitted through a mandibular complete denture base to the edentulous mandible, would be influenced by the lingualized occlusion. This investigation was performed to analyze the stresses induced in a three-dimensional photoelastic edentulous mandible, when a load is applied to the denture arranged into lingualized occlusion in centric relation, lateral and protrusive functional position. The mounted denture on a Dentatus Type ARO articulator was loaded in a pure vertical direction with 15kgs on the center of articulator in each case and the stresses were frozen into epoxy edentulous model at $127^{\circ}C$ in the stress freezing furnace. The stress-frozen epoxy models were sliced with diamond disc saw into 4mm thick. The slices were examined with a circular polariscope. The results were as follows: 1. In centric relation, the stresses were low at anteriors, and gradually increase to the premolar, molar area and highest at the first molar and gradually decrease from the second molar and lowest at the retromolar pad region. The lingual side showed higher stresses than labiobuccal side. 2. In lateral functional position, the working side showed higher stresses than the balancing side. In working side, the lingual side showed higher stresses than the buccal side and in balancing side, the buccal side showed higher stresses than the lingual side. 3. In protrusive position, stress distribution was symmetrical on the posteriors and the stresses were concentrated at the labial side of the anteriors.

  • PDF

Effect of MAD Snoring Design on Pharyngeal Airway Dimension (하악전방이동 코골이 장치의 수직 교합량이 상기도에 미치는 영향)

  • Ra, In-Sil;Lee, Jang-Hoon
    • Journal of Digital Convergence
    • /
    • v.15 no.10
    • /
    • pp.307-314
    • /
    • 2017
  • In this study, a minimum amount of the vertical occlusion was secured differently in each type of mandibular advance devices snoring and Class I malocclusion patients wore these devices. This study analyzes, after the use of devices, a different amount of the vertical occlusion results in a change of the area of upper airway by additional changes such as mandibular position, muscle changes, tongue position. The higher the vertical amount, the area of the upper airway was shown smaller, And if the patient's tongues was prevented from the distal movement, the area of the upper airway had increased, To reduce snoring, doctors should accurately diagnose patients' occlusal relationships and select a MAD snoring that is appropriate for the occlusion. The dental technician who builds the selected device should also consider design settings such as the amount of vertical occlusion, the finish lines, and the thickness of the device to increase the effectiveness of the device.

Ischemic Infarcion Model by Middle Cerebral Artery Occlusion using Allogenic Blood Clot in Beagle Dogs (비글견에서 동종혈전 색전술을 이용한 중간대뇌동맥의 허혈성 뇌경색 모델)

  • Kim, Younghwan;Choi, Sooyoung;Lee, Kija;Han, Woosok;Choi, Hojung;Lee, Youngwon
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.10-15
    • /
    • 2016
  • The purpose of this study was to establish reproducible ischemic infarction model using allogenic blood clot in beagle dogs and identify induced ischemic lesion after middle cerebral artery occlusion using magnetic resonance imaging (MRI) and histopathologic findings. Twenty eight male beagle dogs with no evidence of neurologic disease were experimented. Allogenic embolus was made using a healthy beagle dog. After internal carotid artery (ICA) was exposure, 16G catheter was introduced through the ICA. The dog was administered 0.3 ml blood clot for 15 seconds followed by 3 ml of saline for 15 seconds. MRI scans were performed with 1.5T to evaluate ischemic lesion at 7 days after middle cerebral artery occlusion procedure. Evaluation parameters of MRI include location, distribution, infarction type, margin, shape, mass effect and intensity of T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid attenuated inversion recovery (FLAIR) sequence, diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC). On MRI, all dogs (28/28) showed focal or multifocal lesion including telencephalon and thalamus lesions, especially caudate nucleus (24/28). These lesions had well-defined margin from adjacent brain parenchyma, none or mild mass effect and various shape. Most of dogs appeared hyperintensity on T1WI, T2WI, FLAIR, and DWI/ADC, corresponding to chronic infarction. These lesions were histopathologically confirmed atrophic changes and unstained lesion. In conclusion, MRI is the useful method to provide information about ischemic infarction in dogs and the best reproducible ischemic infarction model was developed by using allogenic blood clot.

Study on Training levee Dimension for Reduction of River Mouth Occlusion (하구폐색저감을 위한 도류제 제원에 관한 연구)

  • Choi, Chang Jin;Choo, Yean Moon;Kim, Sung Bum;Jee, Hong Kee
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.139-151
    • /
    • 2014
  • In this study, virtual confluence of $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$ type flowing into main channel was designed to comprehend occlusion phenomenon of the mouth of river, then performed numerical analysis using the RMA-2 and SED2D model of SMS according to application of 40m, 60m, 80m, 100m Training levee corresponding to main channel width ratio. Results of simulations analysis are summarized as follows. Applying appropriate Training levee length determined by numerical analysis results, Training levee dimension for occlusion reduction was studied through the analysis of velocity, water level, bed variation at the Gamchen confluence and Wichen confluence.

FRS-OCC: Face Recognition System for Surveillance Based on Occlusion Invariant Technique

  • Abbas, Qaisar
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.8
    • /
    • pp.288-296
    • /
    • 2021
  • Automated face recognition in a runtime environment is gaining more and more important in the fields of surveillance and urban security. This is a difficult task keeping in mind the constantly volatile image landscape with varying features and attributes. For a system to be beneficial in industrial settings, it is pertinent that its efficiency isn't compromised when running on roads, intersections, and busy streets. However, recognition in such uncontrolled circumstances is a major problem in real-life applications. In this paper, the main problem of face recognition in which full face is not visible (Occlusion). This is a common occurrence as any person can change his features by wearing a scarf, sunglass or by merely growing a mustache or beard. Such types of discrepancies in facial appearance are frequently stumbled upon in an uncontrolled circumstance and possibly will be a reason to the security systems which are based upon face recognition. These types of variations are very common in a real-life environment. It has been analyzed that it has been studied less in literature but now researchers have a major focus on this type of variation. Existing state-of-the-art techniques suffer from several limitations. Most significant amongst them are low level of usability and poor response time in case of any calamity. In this paper, an improved face recognition system is developed to solve the problem of occlusion known as FRS-OCC. To build the FRS-OCC system, the color and texture features are used and then an incremental learning algorithm (Learn++) to select more informative features. Afterward, the trained stack-based autoencoder (SAE) deep learning algorithm is used to recognize a human face. Overall, the FRS-OCC system is used to introduce such algorithms which enhance the response time to guarantee a benchmark quality of service in any situation. To test and evaluate the performance of the proposed FRS-OCC system, the AR face dataset is utilized. On average, the FRS-OCC system is outperformed and achieved SE of 98.82%, SP of 98.49%, AC of 98.76% and AUC of 0.9995 compared to other state-of-the-art methods. The obtained results indicate that the FRS-OCC system can be used in any surveillance application.

Closure of patent ductus arteriosus with a vascular plug in a German Shepherd dog

  • Han-Joon Lee;Taehyung Kwon;Gyeonggook Park;Dong-Kwan Lee;Joong-Hyun Song;Kun-Ho Song
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.1
    • /
    • pp.55-59
    • /
    • 2024
  • A 4-year-old, spayed female German Shepherd dog (GSD) weighing 22.4 kg was referred to Chungnam National University Veterinary Medicine Teaching Hospital with the chief complaint of a cardiac murmur. A continuous murmur was detected at the left basilar region upon auscultation. In the thoracic radiographs, slight bulging of the aorta, the main pulmonary artery, and the left atrium were observed. Echocardiography revealed continuous turbulent flow directed from the main pulmonary artery towards the pulmonary valve and consistently within the main pulmonary artery. Based on all the results, a diagnosis of type II A patent ductus arteriosus (PDA) was made, and plans were established to treat it with transcatheter occlusion. Transcatheter occlusion was performed using a vascular plug and successfully deployed at the PDA. The patient did not exhibit any complications. GSDs are relatively less common compared to small-breed dogs in South Korea. Considering that GSDs are predisposed to PDA, it is crucial to periodically assess the presence of PDA through auscultation and echocardiography, even in the absence of clinical signs. Transcatheter occlusion using a vascular plug can be an option for treatment and can yield favorable outcomes.

Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • PURPOSE. This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. MATERIALS AND METHODS. Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion types (Group I: Canine protected occlusion, Group II: Unilaterally balanced occlusion, Group III: Bilaterally balanced occlusion). Two strain gauges were attached to each implant abutment. The programmed dynamic loads (0 - 300 N) were applied using a chewing simulator (MTS 858 Mini Bionix II systems, MTS systems corp., Minn, USA) and the strains were monitored. The statistical analyses were performed using the paired t-test and the ANOVA. RESULTS. The mean strain values (MSV) for the working sides were 151.83 ${\mu}{\varepsilon}$, 176.23 ${\mu}{\varepsilon}$, and 131.07 ${\mu}{\varepsilon}$ for Group I, Group II, and Group III, respectively. There was a significant difference between Group II and Group III (P < .05). Also, the MSV for non-working side were 58.29 ${\mu}{\varepsilon}$, 72.64 ${\mu}{\varepsilon}$, and 98.93 ${\mu}{\varepsilon}$ for Group I, Group II, and Group III, respectively. One was significantly different from the others with a 95% confidence interval (P < .05). CONCLUSION. The MSV for the working side of Groups I and II were significantly different from that for the non-working side (Group I: t = 7.58, Group II: t = 6.25). The MSV for the working side of Group II showed significantly larger than that of Group III (P < .01). Lastly, the MSV for the non-working side of Group III showed significantly larger than those of Group I or Group II (P < .01).

Comparison of Intraoperative Somatosensory Evoked Potential(SSEP) Monitoring During Aneurysm Surgery : ACA Aneurysms vs MCA Aneurysms (전대뇌동맥과 중대뇌동맥 동맥류 수술시 체성감각유발전위의 모니터링의 비교, 분석)

  • Choi, Kwang Yeong;Kim, Gook Ki;Lim, Young Jin;Kim, Tae Sung;Leem, Won;Rhee, Bong Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.281-288
    • /
    • 2001
  • Objectives : The purpose of this study is to evaluate the usefulness of SSEP monitoring during intracranial aneurysm surgery and compare the characteristics of wave change in relation to neurologic changes between ACA aneurysms and MCA aneurysms. Methods : During recent three years(between January 1997 and November 1999), intraoperative SSEP monitoring had been done in 63 operations for intracranial aneurysms. We had monitored the median nerve SSEP during surgery for aneurysms of MCA and the posterior tibial nerve SSEP for aneurysms of ACoA or ACA. A more than 50% reduction of any cortical SEP response was considered to be a significant SEP change, compared to its baseline value before the start of surgery. Changes in the SEPs were categorized as follows : Type IA, no significant amplitude changes without temporary clipping ; Type IB, no significant amplitude changes with temporary clipping ; Type II, significant changes with temporary clipping and complete return to control amplitude ; Type III, significant changes with temporary clipping and incomplete return to control amplitude ; Type IV, significant changes with temporary clipping and more decreased amplitude changes. Results : Among the 63 intraoperative monitoring, there were 37 cases of ACA aneurysms(An), and 26 of MCA An. The temporary proximal arterial occlusion during surgery were performed in 31(83.8%)cases of ACA An, 22(84.6%) of MCA An. Seven of the 31 ACA An(22.6%) and ten of the 22 MCA An(45.5%) had significant changes. The type were as follows : 4 patients with type II and 3 with type III in the ACA An ; 3 patients with type II and 3 with type III and 4 with type IV in the MCA An. In both group type II changes had no new postoperative neurological deficit. All 6 patients with type III had new neurological deficits ; However, One case in the ACA An and two cases in the MCA An. had transient neurologic deficit and improved markedly over the next two months. All 4 type IV changes in the MCA An. had permanant neurologic deficits. Two out of 30 cases(6.7%) in the ACA An. and one out of 16 cases(6.3%) in the MCA An. without significant amplitude change had new neurologic deficit postoperatively. Conclusion : Based on this study, Intraoperative SSEP monitoring during aneurysm surgery would provide useful information for detecting cerebral ischemia. SSEP response during surgery for MCA An. is more sensitive than ACA An. Otherwise, there were no meaningful difference in rate of false negativity.

  • PDF