• Title/Summary/Keyword: Occlusion type

Search Result 292, Processing Time 0.027 seconds

Analgesic Effect of Botulinum Toxin on Neuropathic Pain after Trigeminal Nerve Injury (삼차신경 손상에 의한 신경병증성 통증에서 보툴리눔 독소의 진통 효과)

  • Kim, Young-Gun;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2012
  • Botulinum toxin type A (BoNT-A) has been applied successfully to treat chronic migraine, dystonia, spasticity and temporomandubular disorders(TMDs) as well as frontal wrinkle and glabella wrinkle. Recently it has been reported that BoNT-A, reversibly blocks presynaptic acetylcholine release, also inhibits the release of substance P, CGRP(calcitonin gene related peptide) and glutamate related to peripheral sensitization and neurogenic inflammation in sensory nerve, In this study we reviewed animal nerve injury model such as rat and rabbit and identify the analgesic effect and mechanism of nerve injury pain after dental treatment.

Impression procedures for removable partial dentures (가철성 국소의치 제작을 위한 인상채득)

  • Heo, Yu-Ri;Son, Mee-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.152-158
    • /
    • 2014
  • To fabricate removable partial denture which provide patient's comfort and maintain oral health, cast fabrication which reproduce anatomical and functional state of mouth is needed. Diagnostic cast and master cast are produced through the process of preliminary impression and final impression taking. Both of remaining teeth and edentulous area should be well taken in removable partial denture impression. According to the supporting type of partial denture, impression material and method can be changed. Therefore, understanding of impression procedure is essential for the accurate clinical application.

Delayed-type retrobulbar hematoma caused by low temperature after reconstruction of inferior blow-out fracture

  • Lee, Da Woon;Kim, Tae Hyung;Choi, Hwan Jun;Wee, Syeo Young
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.2
    • /
    • pp.110-114
    • /
    • 2021
  • Retrobulbar hemorrhage is a disastrous condition that can lead to permanent blindness. As such, rapid diagnosis and treatment are critical. Here, we report a patient who presented with retrobulbar hemorrhage following an orbital floor fracture. Restoration of inferior orbital wall with porous polyethylene implant was underwent. Four days after the orbital floor reconstruction, the patient smoked a cigarette outdoors in -3℃ weather. Cold temperature and smoking caused an increase in his systemic blood pressure. The elevated blood pressure increased intraorbital pressure to the extent of causing central retinal artery occlusion and exacerbated oozing. During exploratory surgery, 3 mL of hematoma and diffuse oozing without arterial bleeding were observed. Prompt diagnosis and treatment prevented vision impairment. Few studies have reported on the risk factors for retrobulbar hemorrhage. This case showed that daily activities, such as exposure to cold weather or tobacco smoking, could be risk factors for retrobulbar hemorrhage.

A Study on Assembly Part Recognition Using Part-Based Superquadric Model (부품 기반한 수퍼쿼드릭 모델을 이용한 기계부품 인식에 관한 연구)

  • 이선호;홍현기;최종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4B
    • /
    • pp.734-742
    • /
    • 2000
  • This paper presents a new volumetric approach to 3D object recognition by using PBSM (part-based superquadric model). The assembly part object can be constructed with the set of volumetric primitives and the relationships between them. We describe volumetric characteristics of the model object with superquadric parameters. In addition, our model base has the relationships between volumetric primitives as well as the surface information : the surface type, the junction type between neighboring surfaces. These surface properties and relationships between parts are effectively used in recognition process. Our integrated method is robust to recognition of the identity, position, and orientation of randomly oriented assembly parts. Furthermore, we can reduce the effects of self-occlusion and non-linear shape changes according to viewpoint. In this paper, we show that our integrated method is robust to recognition of the identity, position, and orientation of randomly oriented assembly parts through experimental results.

  • PDF

Evaluation of fitness in implant screw as tightening torque in dental laboratory (기공실에서의 임플란트 토크값에 따른 적합도 평가)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.310-315
    • /
    • 2015
  • Purpose: The purpose of this study was to measure the tightening torque for dental implant in dental laboratory and to analyze of the effects of different tightening torque. Materials and Methods: The tightening torque for dental implant in dental laboratory were measured by digital torque gauge. The length of abutment and analog were measured as tightening torque of manufacturer's instructions and the measured value. And the data were statically analyzed. Results: The mean tightening torque of implant screw in dental laboratory was $1.563{\pm}0.332Ncm$. The external type implant system of total length were showing no significant differences but the internal type implant system had difference significant (P < 0.05) when compared with tightening torque. Conclusion: The implant prosthesis should be made under manufacturer's instructions especially as tightening torque of screw. For the fidelity of implant prosthesis, dental technician should learn how to use the torque gauge.

Removable prosthetic rehabilitation in patient with maxillofacial defects caused by gunshot: A case report (총상으로 인한 악안면 결손을 가진 환자에 대한 가철성 보철물 수복증례)

  • Lee, Donggyu;Kang, Jeongkyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.198-204
    • /
    • 2017
  • Maxillofacial defect comes from congenital defect, trauma and surgical resection. Patients with intraoral defect are commonly related to maxillary defect and they need prosthetic rehabilitation. Functional reconstruction of partially edentulous mandible has many limitations. However, if both condyles are intact, maxillofacial prosthesis using partial denture give competent results. In this case, a patient of 58 year-old male has a defect on palate and left mandibular posterior teeth from gunshot. The maxillary defect of this patient is Class IV according to Aramany classification and the mandibular one is Type V according to Cantor and Curtis classification. For retention of the obturator, remaining teeth are fully utilized and artificial teeth are arranged harmoniously to provide stable occlusion. Mandibular RPD covered limited range of deformed soft tissue derived from mandibular resection surgery. With these treatments, the patient in this case showed improvements in mastication, swallowing and speech.

Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials (대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구)

  • Park, Young-Bae
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

Association of polymorphisms in thromboxane A2 receptor and thromboxane A synthase 1 with cerebral infarction in a Korean population

  • Park, Sun-Ah;Park, Byung-Lae;Park, Jeong-Ho;Lee, Tae-Kyeong;Sung, Ki-Bum;Lee, You-Kyoung;Chang, Hun-Soo;Park, Choon-Sik;Shin, Hyoung-Doo
    • BMB Reports
    • /
    • v.42 no.4
    • /
    • pp.200-205
    • /
    • 2009
  • Thromboxane A2 (TBXA2) is a potent vasoconstrictor in cerebral circulation and is a known contributor to the pathogenesis of cerebral infarction. Thromboxane A2 synthase 1 (TBXAS1) and thromboxane A2 receptors (TBXA2R) are key components in TBXA2 function. We examined whether genetic variants in TBXA2R and TBXAS1 are risk factors for cerebral infarction by genotyping 453 Korean patients with noncardiogenic cerebral infarction and 260 controls. A few, specific polymorphisms in the TBXA2R (-3372G>C, +4710T>C and 4839T>C) and TBXAS1 (+16184G>T, +141931A>T and +177729G>A) genes were chosen and investigated. Logistic regression showed the frequencies of TBXAS1+16184G>T and TBXAS1-ht3 were significantly more frequent in cerebral infarction (P = 0.002, OR = 2.75 and P = 0.01, OR = 1.57, respectively), specifically in small-artery occlusion (SAO) type of cerebral infarction (P = 0.0003 and 0.005, respectively). These results suggest specific TBXAS1 gene polymorphisms may be a useful marker for development of cerebral infarction, especially SAO type in Korean population.

Characterization of the Stress in the Luting Cement layer Influenced by Material Properties of Full Veneer Crown (전부피개관의 물성과 시멘트의 물성이 시멘트 내부의 응력에 미치는 영향)

  • Lee, Jun-Young;Lee, Kyu-bok;Lee, Chung-Hee;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • The objective of this study was to test the effects of crown material, cement type, the direction in which stress is applied and distribution of luting cement that might lead to cement microfracture using 2D Finite Element Method. Twenty three finite element models with a chamfer margin configuration were generated for a mandibular first molar. Crown models exhibited four crown materials: type 3 gold alloy, Ni-Cr alloy, ceramic and composite resin, and two luting cements: zinc phosphate and glass ionomer cements with a thicknesses of $70{\mu}m$. Modeled crowns were loaded axially or obliquely at unit load of 1 N. Areas and levels of stress concentrations within the cement were determined. Stress in the cement layer at the margins of crowns were higher than those in the area away from the margin. Stress under oblique loads were much higher than under axial load. The stiffer crown material produced higher stress and similarly, higher stress were found in cements with the greater Young's modulus.

Analysis of 363 Consecutive Patient with Acute Ischemic Stroke f개m the Hanbang Stroke Registry (뇌혈관 한의학 기반 연구사업 등록자료를 통한 363명의 급성기 뇌경색 환자의 기초 임상자료 분석)

  • Sun, Jong-Joo;Jung, Jae-Han;Moon, Sang-Kwan;Cho, Ki-Ho;Ko, Seong-Gyu;Chen, Chan-Yong;Han, Chang-Ho;Jung, Woo-Sang
    • The Journal of Korean Medicine
    • /
    • v.28 no.1 s.69
    • /
    • pp.35-41
    • /
    • 2007
  • Objectives : To gain better insights on the characteristics of stroke patients admitted to oriental medical hospitals, we analyzed the data of 363 consecutive patients with acute ischemic stroke from Hanbang Stroke Registry supported by the Ministry of Science and Technology of Korea. Methods : Subjects' enrollment was in the oriental medical hospitals of 3 universities located in the metropolitan region from October 2005 to October 2006. We assessed the subjects' general characteristics, risk factors, and etiology of stroke. Each patient's TOAST classification type was confirmed by two independent specialists. Those were small vessel occlusion (SVO), large artery atherosclerosis (LAA), cardioembolism (CE), stroke with other determined etiology (SOE), and stroke with undetermined etiology (SUE).Results 'The distribution of the subjects' general characteristics and risk factors for stroke were similar with result storm previous reports. However, in the TOAST classification, SVO was the major type occupying 78.5% in the total subjects, which is the highest share compared with other research with similar methods. These results imply that patients with more severe symptoms rarely visit oriental medical hospitals. Conclusion : Assuming that this research will continue adding patient's data continuously, this work will help us to understand the features of stroke patients at oriental medical hospitals, and contribute to expansion of the Korean Hanbang Stroke Data Bank.

  • PDF