• Title/Summary/Keyword: Occlusal contacts

Search Result 72, Processing Time 0.024 seconds

A Study on the Changes of Occlusal Contacts after Electromyographic Biofeedback Therapy (E.M.G. biofeedback therapy에 의한 occlusal contact의 변화에 관한 련구)

  • 김영주;이승우;김영구
    • Journal of Oral Medicine and Pain
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 1985
  • Changes of occlusal contacts after E.M.G. biofeedback therapy with D.D.S. (Self control system, EMG 220, Sandiago California) was investigated in 20 SNUH students and residents with normal occlusion. Treatment time was 30 minutes on every subject. Occlusal contacts of before biofeedback therapy were taken at 4: 00 P.M. and that of after biofeedback therapy were taken at 4:40 P.M. Author compared the occlusal contacts before biofeedback therapy with that of after biofeedback therapy. The obtained results were as follow : 1. The number of occlusal contacts was 23.9, before biofeedback therapy and, 26.3, after biofeedback therapy. 2. The percentage of accentuated contact to diffuse contact was 78.5%, before treatment and 38.8% after treatment. 3. 6 heaviest contacts were changed 4.3 teeth per one subject after biofeedback therapy.

  • PDF

COMPUTERIZED EVALUATION OF OCCLUSAL CONTACTS IN CENTRIC CLOSURE IN DISTAL EXTENSION PARTIAL DENTURE CASES (유리단 국소의치 환자에서 T-scan system을 이용한 중심교합시에 교합접촉 양상 연구)

  • Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.4
    • /
    • pp.565-573
    • /
    • 1992
  • This clinical study was to analyze occlusal contacts in maximum intercuspation on distal extension partial denture and to compare tooth contact state between the denture teeth and abutment teeth by time mode and force mode using the T-scan system. The subjects ware twenty-one adult patients with upper natural teeth and lower distal extension partial denture. Conclusion : 1. The patient with simultaneous occlusal contacts both denture tooth and abutment and bilaterally in Kennedy Class I cases was one-sixth, but there was no one with symmetric occlusal and equal force among bilateral denture teeth and abutments. 2. The five-fifteenth of Kennedy Class I case patients resulted in simultaeous occlusal contacts bet-ween denture teeth and abutments but no one has the symmetric occlusal contacts and unifarm force between denture teeth and abutment teeth.

  • PDF

An occlusal contact analysis of lateral mandibular movement using T-Scan system (T-Scan system을 이용한 하악 측방운동 시 교합접촉 분석)

  • Song, Joo-Hun;Joo, Se-Jin;Lee, Ho-Sun;Kang, Dong-Wan;Lee, Gyeong-Je
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.128-137
    • /
    • 2015
  • Purpose: Most of the former studies about the occlusal contact patterns during the mandibular movement focused on foreigner. The purpose of this study is analyzing the occlusal contacts of young Koreans by using T-Scan system. Materials and methods: The sample size was 87 and the occlusal contacts of each right and left lateral movements were measured from the maximum intercuspation to the 3mm excursive position for three times respectively. All of the occlusal contacts were double checked through the thin metal foil. The results were categorized as two; 1) considering occlusal contact patterns on working side only, 2) considering occlusal contact patterns on working and nonworking sides. Results: The results showed that the nonworking side occlusal contacts play major roles in the lateral mandibular movement. In both cases of considering with and without the nonworking side occlusal contacts, the group function was the most prevalent. In the working side, the contacts were the most frequent in canine and the frequency of contacts was decreased as the distance was increased from canine to molar. In the nonworking side, the contacts were the most frequent in second molar. And the gender factor was statistically significant (${\alpha}$=.05), as females have more nonworking side occlusal contacts in this study. Conclusion: Among the three factors of anterior guidance, the group function was the most dominant factor. The analysis of 87 samples showed that canine contact was the most frequent in the working side and second molar contact was the most common in the nonworking side.

The Effect of Head Posture Change on Initial Occlusal Contacts (두부의 자세 변화가 초기 교합접촉에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.195-204
    • /
    • 1995
  • The purpose of this study was to evaluate effect of head posture change on initial occlusal contacts through measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture. Two special devices were designed and constructed. Mandibular movement replicator was used to assess reliability of the K6 diagnostic system(MKG; Myo-tronic Inc, Seatle, USA) and head posture calibrator was used to maintain the constant head posture during experiment. We measured difference of distance between initial occlusal contact and maximum intercuspal position with MKG in upright, supine, 45 degrees extension, 30 degrees flexion, 30 degrees right and left bending postion of the head. The Frankfurt horizontal plane was used as a reference plane. 21 adults aged from 23 to 25 were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. The obtained results were as follows : The mean absolute distances between initial occlusal contact and maximum intercuspal postion were 0.39(0.18mm in the upright position, 0.65(0.37mm in the supine position, 0.59(0.33mm in the 45 degree extension, 0.70(0.53mm in the 30 degrees flexion, 1.12(1.10mm in the 30 degrees right bending and 1.94(0.67mm in the 30 degrees left bending of the head. The positions of the initial occlusal contacts have a tendency to locate anterior, left and inferior to maximal intercuspal position in upright position, posterior and inferior in supine position and 45 degrees extension, anterior and inferior in 30 degrees flexion, right and inferior in 30 degrees right bending, and left and inferior in 30 degrees left bending of the head. There were significant differences among the initial occlusal contacts in each head postures(P<0.0001). Therefore, we need to check initial occlusal contacts in the altered head posture during occlusal analysis and adjustment of occlusal appliance and dental occlusion for diagnosis and treatment of temporomandibular disorder.

  • PDF

A STUDY ON THE OCCLUSAL CONTACT OF THE SUBJECTS WITH TEMPOROMANDIBULAR JOINT SOUND (측두악관절 잡음자의 교합접촉에 관한 연구)

  • Yoon, Kwang-Hyun;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.51-61
    • /
    • 1993
  • The purpose of this study was to evaluate a possible occlusal contributing factor on the pathogenesis of temporomandibular joint sound by a new computer aided method for analysis of occlusal contact. 20 subjects without temporomandibular joint sound as control group and 20 subjects with temporomandibular joint sound as experimental group in the TMJ clinic, dental infirmary, School of Dentistry, Chosun University were selected so as to investigate the distribution and intensity of the bilateral occlusal contacts on silicone rubber bites in habitual intercusal position through a computer aided system. The following results were obtained : 1. The distribution and intensity of the occlusal contact could be analyzed and expressed as color density value per levels by this computer aided method. 2. There was not statistical significance between control and experimental group in total occlusal contacts. 3. There was statistical significance between control and experimental group In the total difference of right and left occlusal contacts.(P<0.05).

  • PDF

A Study on the Effects of Chewing Side Preference on the Pattern of Occlusal Contacts (저작습관에 따른 교합접촉의 변화양태에 관한 연구)

  • Sun-Oh Kwon;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.15 no.1
    • /
    • pp.117-124
    • /
    • 1991
  • The purpose of his study was to investigate the variations of occlusal contact pattern according to chewing side preference. The author selected 59 dental students (mean age 23.6 years) who had no signs and symptoms of masticatory disorders and divided into two groups, that is, bilateral chewing side group and unilateral chewing side group, respectively. For recording, T-Scan System(Teksan Inc., USA) was used and the recorded occlusal contacts were examined as to the number of occlusal contacts, points distribution in dental arch, time sequence and force snapshot. The obtained results were as follow s: 1. Total number of occlusal contacts were more in unilateral chewing side group and there were significant difference in number between right and left side or between chewing and less-chewing side in all two groups. 2. All items related to time sequence showed no statistical significant difference between two groups in any case. 3. Unilateral chewing side group had more occlusal contact force than bilateral group, especially in chewing side. From the above finding, the author considered that there was occlusal unbalance in unilateral chewing side group. 4. Chewing side preference would possibly have more effects on the occurrence rate of anterior tooth contact that the rate of prolonged their contact but proved.

  • PDF

Evaluation of biogeneric design techniques with CEREC CAD/CAM system

  • Arslan, Yeliz;Nemli, Secil Karakoca;Gungor, Merve Bankoglu;Tamam, Evsen;Yilmaz, Handan
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.431-436
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate occlusal contacts generated by 3 different biogeneric design modes (individual (BI), copy (BC), reference (BR)) of CEREC software and to assess the designs subjectively. MATERIALS AND METHODS. Ten pairs of maxillary and mandibular casts were obtained from full dentate individuals. Gypsum cast contacts were quantified with articulating paper and digital impressions were taken. Then, all ceramic crown preparation was performed on the left first molar teeth and digital impressions of prepared teeth were made. BI, BC, and BR crowns were designed. Occlusal images of designs including occlusal contacts were superimposed on the gypsum cast images and corresponding contacts were determined. Three designs were evaluated by the students. RESULTS. The results of the study revealed that there was significant difference among the number of contacts of gypsum cast and digital models (P<.05). The comparison of the percentage of virtual contacts of three crown designs which were identical to the contacts of original gypsum cast revealed that BI and BR designs showed significantly higher percentages of identical contacts compared with BC design (P<.05). Subjective assessment revealed that students generally found BI designs and BR designs natural regarding naturalness of fissure morphology and cusp shape and cusp tip position. For general occlusal morphology, student groups generally found BI design "too strong" or "perfect", BC design "too weak", and BR design "perfect". CONCLUSION. On a prepared tooth, three different biogeneric design modes of a CAD/CAM software reveals different crown designs regarding occlusal contacts and morphology.

A correlation between bruxism and eccentric occlusal interferences (이갈이와 편심위 교합간섭의 상관관계 분석)

  • Lee, Ho-Sun;Kim, Mi-Gyeong;Jin, Soo-Yoon;Kim, Hee-Jung;Lee, Gyeing-je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.253-261
    • /
    • 2018
  • Purpose: The purpose of this study was to analyze correlation between bruxism and occlusal contacts on balancing side. Materials and Methods: The purpose of this study is to compare the difference of group function and balancing side occlusal contacts according to bruxism and sex, A total of 100 adults that aged 26-37 years (39 bruxers and 61 non-bruxers) were examined. The lateral excursion and balanced occlusal contacts were analyzed to determine the correlation with bruxism. The occlusal contacts were recorded by T-Scan system and articulating paper. Results: The group function was the highest in 61.5% of bruxers and 47.5% of non-bruxers. In comparison between males and females, group function was 58.9% in males and 37.0% in females. Occlusal contacts on non-working side occurred in 48 out of 100 patients. There were 51.2% of the cases in the bruxers and 46.0% in the non-bruxers. Statistically, there was no correlation between the bruxism and occlusal contacts on non-working side. There was no correlation between sex and balancing occlusal contacts. Conclusion: There was no significant correlation between bruxism and occlusal contacts on non-working side. The group function was the highest in bruxers when lateral excursion was occurred.

The Effect of Head Posture Change on Initial Occlusal Contact in Temporomandibular Disorder Patient (측두하악 장애환자에서 두부자세 변화가 초기 교합접촉에 미치는 영향)

  • Weon-Ho Choi;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.489-496
    • /
    • 1995
  • The purpose of this study was to evaluate an effect of change on head posture initial occlusal contacts with measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture in TMDs patient. For this study, 24 patients from age 13 to 36 were selected, they were examined health history taken, patients who have sign and symptoms of TMDs were examine before the study. For the normal group, 21 adults from age 23 to 25 were selected. They have normal or class I molar relationship, and have no other prosthetic restorations. Difference on distance between initial occlusal contact and maximum intercuspal position with mandibular kinesiograph$(MKG^R)$(K6 diagnostic system, Myo-tronic Inc, USA) in upright, supine, 45$^{\circ}$ extension, 30$^{\circ}$ flexion position of the head were measured. The Frankfort horizontal plane was used as a reference plane. The results were as follows : 1. There were significant differences between initial occlusal contacts of the normal and patient group on upright position and 30$^{\circ}$ flexion of the head(p<0.05, p<0.01) 2. The position of the initial occlusal contacts have a tendency to place anterior and inferior to maximal intercuspal position in upright position and 30( flexion of the head as well as posterior and inferior in supine position and 45$^{\circ}$ extension of the head in the normal and patient groups. 3. There were significant differences among the initial occlusal contacts between uptight and supine position; upright and 45$^{\circ}$ extension of the head(p<0.05); supine position and 30$^{\circ}$ flexion of the head, .and 30(flexion and 45$^{\circ}$ extension of the head in the patient group(p<0.01) The result have shown that after treatment on the supine position, it may be necessary to check occlusal contact on the upright position as well ass flexion of the head. It may need careful adjustment in occlusal condition on upright position of TMDs patient.

  • PDF

Comparison of two computerized occlusal analysis systems for indicating occlusal contacts

  • Jeong, Min-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.49-54
    • /
    • 2020
  • PURPOSE. The purpose of this study was to compare the performance of Accura to that of the T-scan for indicating occlusal contacts. MATERIALS AND METHODS. Twenty-four subjects were selected. Their maxillary dental casts were scanned with a model scanner. The Stereolithography files of the casts were positioned to align with the occlusal plane. Occlusal surfaces of every tooth were divided into three to six anatomic regions. T-scan and Accura recordings were made during two masticatory cycles. The T-scan and Accura images were captured at the maximum bite force and overlapped to the cast. Photographs of interocclusal records were used as the reference during overlap. The occlusal contacts were counted to compare the T-scan and Accura. McNemar's test was used for statistical significance and the corresponding P-values were calculated from a chi-square distribution with one degree of freedom. The accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Accura were calculated relative to the T-scan values as a control. RESULTS. No statistical differences (P>.05) were found between the T-scan and Accura methods. The accuracy of Accura was 75.8%, sensitivity was 82.1%, specificity was 60.1%, PPV was 82.9%, and NPV was 60.1%. CONCLUSION. Accura could be another possible option as a computerized occlusal analysis system for indicating occlusal contacts at maximum intercuspation.