• Title/Summary/Keyword: Occlusal analysis

Search Result 455, Processing Time 0.021 seconds

CLINICAL STUDY OF THE SKELETAL CL III MALOCCLUSION PATIENTS AFTER 2-PHASE SURGICAL-ORTHODONTIC TREATMENT (골격성 제III급 부정교합 환자의 2단계 치료후 경과에 대한 임상적 연구)

  • Cho, Yun-Ju;Kim, Sang-Jung;Kim, Dong-Ryul;Suk, Geon-Jung;Hong, Kwang-Jin;Lee, Jeong-Gu;Sohn, Hong-Bum
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.6
    • /
    • pp.628-635
    • /
    • 2000
  • The purpose of this study was to evaluate the result after 2-phase surgical-orthodontic treatment without preoperative orthodontic treatment for the skeletal Cl III malocclusion patient and to obtain an adequate protocol on the bases of this result. This retrospective study of ten patients who underwent 2-phase treatment were done to evaluate 1) the surgical stability and relapse pattern 2) the facial esthetics 3) the TMJ problem 4) the total time of the treatment. Results were followed : 1) The horizontal relapse of the mandible was 26.8% and didn't show significant differences compared to the conventional 3-phase treatment. But, it was considered that this amount of relapse was the sum of true relapse and autoratation of mandible due to decreased vertical dimension during orthodontic treatment. 2) It was estimated that there's no difference on the ratio of anterior facial height between the subjects and the normal patients. On the horizontal analysis, the mandible of the subjects was located more anteriorly than that of the normal patients. This result showed that there was a need for the accurate preoperative esthetic evaluation and the additional methods for reducing the relapse due to the occlusal interference. 3) Wide variation was noted on the TMJ symptoms of the subjects, however, it was estimated that there's no significant differencees of symptoms compared to that of the conventional 3-phase treatment on literatures. 4) The average of the overall period of treatment was 20.8 months and we obtained reduction of the treatment time compaired to 3-phase treatment on many literatures. Most of the results of this study were similar to the findings of the 3-phase treatment(preoperative orthodontic-orthognathic surgery-postoperative orthodontic), but total time of the treatment was shorter in patients with 2-phase treatment than in those with the conventional 3-phase treatment. With 2-phase treatment, we experienced many advantages compared to the conventional method considering that it was favarable conditions for the teeth, it had the flexibility for the treatment, and it could be the adequate treatment approach for the stomatognathic system. Although this retrospective pilot study had some limitations, due to small samples, the authors would hope that it could serve as a guide for the future researches, and the clinical applications.

  • PDF

THE USE OF REMOVABLE APPLIANCE FOR THE CORRECTION OF MINOR IRREGULARITIES IN ANTERIOR SEGMENT (전치부의 경미한 공간부조화 개선을 위한 가철성 장치의 적용 예)

  • Kwak, Ah-Ram;Choi, Yeong-Chul;Park, Jae-Hong;Choi, Seong-Chul;Kim, Gwang-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.685-693
    • /
    • 2007
  • Class I malocclusion without skeletal problem results from tooth size/arch-size discrepancies, either evidenced by crowding, or spacing problems. Treatment method can be chosen according to dentition, the amount of arch discrepancy, patient compliance, or patient demands. We report of clear aligner and spring aligner that can be applicated in cases of permanent dentition with minimal arch discrepancy in anterior segment. There are some limits of application, but these are very useful appliances in the selective case. When crowding exists, definitive analysis and diagnosis should be made before starting treatment because certain amount of space must be obtained somewhere in the dentition to resolve the crowding. Therefore, appliance should be applied when lacking space is small. Also, in cases with spacing arch circumference is reduced after alignment so no problem in intermaxilla occlusal relationship must be confirmed. In case with crowding, judicious removal of interproximal enamel is indicated.

  • PDF

The evaluation of rotational movements of maxillary posterior teeth using three dimensional images in cases of extraction of maxillary first premolar (3차원 영상을 이용한 상악 소구치 발치공간 폐쇄 후 상악 구치부 회전양상의 평가)

  • Chong, Deuck-Ryong;Jang, Yen-Ju;Chun, Youn-Sic;Jung, Sang-Hyuk;Lee, Sung-Keun
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.451-458
    • /
    • 2005
  • Cephalometric superimposition is unable to evaluate tooth movement along the occlusal plane and the errors of photographing and superimposition of the occlusogram is also inevitable. The purpose of the present study was to evaluate the rotational movements of the maxillary posterior teeth following space closure after extraction of maxillary first premolars. using 3D dental images. In 19 adult females. analysis of rotational movements of the maxillary posterior teeth was performed between the initial and final 3D dental images superimposed on the maxillary hard palate. The results showed a diversity of rotational movements of posterior teeth. The causes of various rotational movements may be different rotation of molars in each case at the beginning of treatment. individual characters of the dental arch and tooth morphology. The results of the study indicate that accurate evaluation of rotational movements of posterior teeth following space closure after extraction of premolars using 3D dental images can be obtained through the subdivision of tooth movement during the initial aligning, space closure and finishing stages.

Shear bond strength of a self-adhesive resin cement to resin-coated dentin (간접수복용 복합레진과 자가 접착 레진 시멘트의 전단결합강도에 레진코팅법이 미치는 영향)

  • Hong, Jee-Youn;Park, Cheol-Woo;Heo, Jeong-Uk;Bang, Min-Ki;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Purpose: The aims of this study were to evaluate the effect of a resin coating on the shear bond strength of indirect composite restoration bonded to dentin with a self adhesive resin cement and to compare the shear bond strength with that of a conventional resin cement. Materials and methods: The occlusal enamels of thirty six extracted noncarious human molars were removed until the dentin flat surfaces of the teeth were exposed. Then, they were divided into 3 groups. The dentin surfaces of group 1 and 3 were left without any conditioning, while the dentin surfaces of group 2 were resin-coated with Clearfil SE bond and a flowable resin composite, Metafil Flo. After all specimens were temporized for 24 hours, indirect composite resin blocks fabricated by Tescera were bonded to dentins by Unicem for group 1 and 2, and by Panavia F for group 3. After 48 hours of water storage, shear bond strengths were measured. The data was analyzed with one-way analysis of variance and multiple comparison test (Tukey method). Results: The shear bond strengths of Unicem applied to resin coated dentin surfaces were significantly higher than those of Unicem and Panavia F used to uncoated dentin surfaces (P<.0001). Conclusion: Application of a resin coating to the dentin surface significantly improved the shear bonding strength of a self adhesive resin cement in indirect restoration.

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

A FINITE ELEMENT ANALYSIS ON STRESS AND DISPLACEMENT ACCORDING TO ISTHMUS WIDTH OF GOLD INLAY CAVITY (금인레이 와동의 폭경에 따른 응력분포와 변위에 관한 유한요소법적 연구)

  • Shin, Gang-Suk;Cho, Young-Gon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.395-411
    • /
    • 1993
  • The purpose of this study was to examine the clear concept of the designs for cavity preparations. Among the several parameters in cavity designs, profound understanding of isthmus width factor would facilitate selection of the appropriate cavity preparation for a specific clinical situation. In this study, the cavities were prepared on maxillary first premolar and filled with gold inaly. A two - dimensional model was composed of 1037 - node triangle elements. In this model, isthmus was varied in width at 1/4, 1/3 and 1/2 of intercuspal width and material properties were given for four element groups, i.e., enamel, dentin, pulp and gold. The 500N occlusal load varied in direction and it was examined using three types of load : concentrated load, divided load and distributed load. The models were also examined with empty cavities using the devided load and distributed load. These models were analyzed the displacement and strees distribution by the two - dimensional Finite Element Method. The results were as follows : 1. All experimental models which filled with gold inlay after cavity preparation were similar direction of displacement with control model under same load type. But in the models with empty cavities, as isthmus width was wider, the degree of displacement was increased at same load type. 2. Among the experimental models which were filled with gold inaly after cavity preparation, the model II showed the least stress concentration under concentrated load and divided load. But in the models with empty cavities, the model III showed the largest stress concentration and tooth fracture is expected regardless isthmus width. 3. All experimental models showed similar displacement pattern beneath restorative material under a concentrated load. In the models with empty cavities, a divided load resulted in a lingual displacement of the lingual cusp, but a distributed load resulted in a buccal displacement of the lingual cusp. In regard to the above results, the restored models were stronger than empty models in respect to the bending moment and tensile stress. The empty models are expected to fracture regardless isthmus width. The safest isthmus width was 1/3 of intercuspal distance, which showed the least stress concentration in respect to the effect of stress distribution.

  • PDF

Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application (유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교)

  • Jun, In-Sik;Kim, Bu-Sub;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF

A comparative study of periodontal conditions around mesially tipped molars by a tipping degree (대구치의 근심 경사 정도에 따른 치주 상태의 비교 연구)

  • Park, So-Young;Choi, Seoung-Hwan;Lee, Su-Jeong;Chang, Moon-Taek;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.41-49
    • /
    • 2002
  • The aim of this study was to compare periodontal conditions around mesially tipped molars by a tipping degree. Patients who had been consecutively treated at the Department of Periodontology, Chonbuk National University Hospital from October 1999 to August 2001 were assessed with radiographs taken at their molar regions. Of all molars investigated, 142 molars of 116 patients tipped mesially more than 10 degrees to the line perpendicular to an occlusal plane were selected for the study. The tipped molars were divided into 2 groups with a reference to a tipping degree, i.e., 66 slightly tipped(group 1 : <$30^{\circ}$) and 76 severely tipped molars (group 2 : ${\geq}30^{\circ}$). Probing depth(PD), plaque retention index(PRI) at mesial surfaces of tipped molars and tooth mobility(TM) were recorded at the clinical examination. Tipping degree(TD) and alveolar bony defect(ABD) at the mesial surface of the molars were measured in a radiograph. The results showed that no statistical differences were found between groups in all measured variables. In Pearson correlation analysis performed in the same group, a positive relationship was shown between PRI and PD in the group 1 and, in the group 2, between PRI and PD as well as PRI and ABD(p < 0.01). However, no statistically significant relationship was found between TD and all other variables in both groups. Within limitations of this study, it may be concluded that tipping degree did not seem to influence periodontal conditions, i.e., PD, ABD and TM of mesially tipped molars per se, but plaque presence/absence seemed to mainly affect the periodontal conditions of the tipped molars.

A PHOTOELASTIC STRESS ANLYSIS IN THE SURROUNDING TISSUES OF TEETH SEATED BY INDIRECT RETAINERS WHEN APPLIED DISLODGING FORCES ON UNILATERAL DISTRAL EXTENTION PARTIAL DENTURES (편측성 후방연장 국소의치의 의치상에 이탈력이 가해질 때 간접유지장치가 장착된 치아 주위조직에 발생하는 응력에 관한 광탄성 분석)

  • Son, Jee-Young;Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.415-430
    • /
    • 1996
  • The purpose of this study was to evaluate the stress distributions in the surrounding tissues of the teeth seated by indirect retainers in three different teeth of unilateral distal extension partial denture when the dislodging forces were applied on denture bases. Three dimensional photoelastic models were made. The teeth on which indirect retainers were seated were mandibular left lateral incisor (Model I), canine (Model II), and first premolar (Model III). The dislodging force with 860mg at $45^{\circ}$ angulation to occlusal plane was applied to each model. Three dimensional photoelastic stress analysis was done, and the records were diagramed and analysed. The results were as follows : The compressive stresses were shown the most on neck portions of buccal, mesial, and distal sides in all three models. Slight tensile stresses were shown on neck portions of lingual sides in all three models. The compressive stresses on buccal side were shown in strength in such order as model I, model II, and model III. The compressive stresses were shown on neck portion of mesial and distal sides of model I and mode II, with model I more than Model II. The compressive stresses were shown only on neck portion of mesial side on Model III. The general overall magnitude of compressive stresses were shown in strength in such order as Model I, Model II, and Model III.

  • PDF

INFLUENCE OF APPLICATION METHODS OF A DENTIN ADHESIVE ON SHEAR BOND STRENGTH AND ADHESIVE PATTERN (상이질 접착제의 적용방법에 따른 전단결합강도와 접착양상에 관한 연구)

  • Park, Sung-Taek;Moon, Joo-Hoon;Cho, Young-Gon;Ohn, Yeong-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.381-391
    • /
    • 1999
  • A new 5th generation adhesive system(ONE-STEP) has been supplied which operators can apply to conditioned tooth surfaces by one simplified step. The purpose of this study was to determine whether different methods of adhesive application and various air drying duration after applying adhesive affect the shear bond strength of composite resin to dentin, and to evaluate the adhesive pattern of composite resin and dentin under SEM. Seventy-seven extracted human molar teeth were cleaned and mounted in palstic test tubes. The occlusal dentin surfaces were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A.). Teeth were randomly divided into 7 groups (n=11), In experimental A group, adhesive was applied to dentin with agitation for 20 sec. In experimental N-A group, adhesive were continuously applied to dentin for 20 sec. Also control and experimental 1, 2, 3, 4 groups were dried for 10, 0, 5, 20, 30 seconds after applying adhesive, respectively, Adhesives were light cured for 10 sec. A gelatin capsule 5mm in diameter was filled with Aelitefil$^{TM}$ composite resin, placed on the treated dentin surface and light cured for 40 see, from three sides, All specimens were stored in distilled water at room temperature for 24 hours. The shear bond strengths were measured using a universal testing machine(AGS-1000 4D, Japan) at a crosshead speed of 5mm/min. An one-way ANOVA and LSD test were used for statistical analysis of the data. For SEM evaluation, seven specimens were made and sectioned. Representive postfracture and seven specimens were mounted on brass stubs, sputter-coated with gold and observed under SEM. The results were as follows : 1. The shear bond strength of experimental A group which adhesive were applied to dentin with agitation was higher than that of experimental N-A group (continuous application), and there was significant difference between two groups (p<0.01). 2. The interface between composite and dentin according to different application methods showed close adaptation in experimental A group and showed tinny gap in experimental N-A group. 3. The shear bond strength accoding to various air drying duration was the lowest value(7.57${\pm}$2.60 MPa) in experimental 1 group, so there was significant difference between experimental 1 group and other four groups (p<0.05). But there was no significant difference of shear bond strength between four groups (p>0.05). 4. The interface between composite and dentin according to various air drying duration showed close adaptation in control group and tinny gap in experimental 3 and 4 groups. But experimental 1 and 2 groups showed $30{\mu}$ and 6 - $10{\mu}m$ thick gaps, respectively.

  • PDF