• Title/Summary/Keyword: Occlusal analysis

Search Result 455, Processing Time 0.019 seconds

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.

Comparison of asymmetric degree between maxillofacial hard and soft tissue in facial asymmetric subjects using three-dimensional computed tomography (안면비대칭자의 3차원 전산단층사진 분석에서 경$\cdot$연조직간 비대칭 정도 차이)

  • Kim, Wang-Sik;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.163-173
    • /
    • 2005
  • The purpose of this study was to compare the asymmetric degree between maxillofacial hard and soft tissues in individuals with facial asymmetry. Computerized tomographies (CT) of 34 adults (17 male, 17 female) who had facial asymmetry were taken. The CT images were transmitted to personal computers and then reconstructed into three-dimensional (3D) images through the use of computer software. In order to evaluate the degree of facial asymmetry, 6 measurements were constructed as the hard tissue measurements while 6 counterpart measurements were taken as the soft tissue measurements. The means and standard deviations were obtained for each measurement using 3D measure, then t-test was used to investigate the differences between each hard tissue measurement and the corresponding soft tissue measurement All measurements used in the present study showed statistically significant differences between the hard and soft tissues. The degree of soft tissue asymmetry was smaller than that of corresponding hard tissue asymmetry in case of chin deviation, frontal ramal inclination difference, and frontal corpus inclination difference. On the other hand, the degree of soft tissue asymmetry was greater than that of underlying hard tissue asymmetry in the measurement of lip canting and lip cheilion height difference The present study suggests that asymmetric differences of hard and soft tissue is observed nu facial asymmetric subjects and thus soft tissue analysis is needed in addition to hard tissue analysis when making an evaluation of facial asymmetry.

INFLUENCE OF INTERIMPLANT DISTANCE ON BONE RESORPTION : A RADIOLOGICAL AND HISTOLOGICAL STUDY IN BEAGLE DOGS (Beagle dog를 이용한 임프란트 사이의 간격에 따른 골흡수에 대한 방사선 및 조직학적 평가)

  • Lee, Su-Youn;Lee, Jae-Wook;Kim, Jin-Wook;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.571-577
    • /
    • 2008
  • Introduction: Possible etiologic factors associated with bone loss around implants after implantation are surgical trauma, occlusal overload, periimplantitis, presence of micro gap and the formation of biologic distances. Tarnow et al. observed that the crestal bone loss was greater when the distance between the implants was <3mm than when the implants were ${\geq}\;3mm$ apart. The aim of this study was to evaluate the influence of different interimplant distance on marginal bone and crestal bone resorption in the beagle dogs. Materials and methods: The mandibular premolars of 5 dogs were extracted bilaterally. After 12 weeks of healing, each dog received 7 implants. On each side, implants were separated by 2mm (Group 1) and by 5mm (Group 2). After 16 weeks of healing, the dogs were sacrificed. Marginal bone loss was determined through linear measurements made between the implant-abutment junctions and the most coronal portions of the bone in contact with the implant surface. A line was drawn uniting the implant-abutment junctions of the adjacent implants, and a linear measurement was made at the midpoint in the direction of the most coronal peak of the interimplant bone crest to determine the crestal bone loss. Both of them was measured radiologically and histologically. Result and conclusion: In radiological analysis, the mean of marginal bone loss was $1.26{\pm}0.14mm$ for group 1 and $1.23{\pm}0.34mm$ for group 2, the mean of crestal bone loss was $1.10{\pm}0.14mm$ for group 1 and $1.02{\pm}0.30mm$ for group 2. The results were not statistically significant between 2 groups. In histological analysis, the mean of marginal bone loss was $1.63{\pm}0.48mm$ for group 1 and $1.62{\pm}0.50mm$ for group 2, the mean of crestal bone loss was $1.23{\pm}0.35mm$ for group 1 and $1.15{\pm}0.39mm$ for group 2. The differences were also not statistically significant. The clinical significance of this result is that the increase in the crestal bone loss results in the increase in the distance between the base of the interproximal contact of the crowns and the bone crest, and this determines if papilla will be present or absent between implants. Considering this fact, keeping up sufficient interimplant distance is important to minimize crestal bone loss.

A STUDY OF THE TEMPOROMANDIBULAR JOINT IN NORMAL OCCLUSION USING T.M.J TOMOGRAM AND CEPHALOGRAM (단층 및 두부 방사선 계측사진을 이용한 정상교합자의 악관절에 관한 연구)

  • Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.16 no.1
    • /
    • pp.85-106
    • /
    • 1986
  • The purpose of this investigation was to know the means of the T.M.J. space and to compare spational differences in centric relation and centric occlusion by the T.M.J. Tomogram and to study the correlation between the articular eminence slope and the lingual surface slope of the maxillary central incisor by the Cephalogram in near normal occlusion subjects. These results could give contribution for the diagnosis of orthodontic treatment and T.M.J. dysfunction and the assessment of orthopedic treatment and orthognathic surgery. 44 young adults (28 men and 16 women, 21 to 27 years of age) were selected from the Dental students in Yonsei Univ. Criteria for selection was normal occlusion, no clinical signs and T.M.J. dysfunction, no history of orthodontic treatment, and no missing tooth. After submental vertex view analysis. each subject was given the T.M.J. Tomogram in centric relation and centric occlusion and the Cephalogram was given with Quint Sectograph. All data was recorded and statistically processed with the CYBER computer system. Results were analyzed: the following findings and conclusions were derived. 1. The mean value for the combined right and left anterior joint space was 2.549mm, the posterior space was 2.260mm, and superior space was 3.31mm in centric relation. The anterior space was 2.316mm, posterior space was 2.474mm, and superior space was 3.435mm in centric occlusion. 2. In the centric relation position, both condyles were placed more posterioly and superioly in their fossae than in the centric occlusion position by the spatial difference. 3. In the centric occlusion position, both condyles were more symmetrically placed in their fossae with equal anterior-posterioly rather than in the centric relation position. 4. The mean articular eminence angle was $48.19^{\circ}$ and the mean fossa height was 7.911mm. A strong positive correlation between the articular eminence angle and fossa height in T.M.J. Tomogram was found. 5. In Cephalometric analysis, there was a strong positive correlation between the articular eminence slope and the lingual surface slope of the upper central incisor to the FH plane, occlusal plane, and S-N plane. 6. There was moderate positive correlation between the S-E measurements and the fossa height, articular eminence angle, and DcGn < F-H.

  • PDF

A study on the anterior tooth size discrepancies among orthodontic patients with varying malocclusions (부정교합자의 전치부 치아크기 부조화에 관한 연구)

  • Kim, Hyeok-Soo;Shim, Hae-Young;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.420-432
    • /
    • 2005
  • Bolton analysis is widely used to predict tooth size discrepancy. but its accuracy has been challenged. The purpose of this study was to describe true anterior tooth size discrepancies among orthodontic patients and to evaluate the factors that affect true anterior tooth size discrepancies. The subjects consisted of 80 patients with varying malocclusions (Class I. Class II. Class III. and Class III surgery) who were treated orthodontically. Pre-treatment models. set-up models from post-treatment models. and lateral cephalometric radiographs were analyzed The results were as follows. The means. the standard deviations. and ranges of anterior Bolton ratio in the present study were somewhat higher than those of Bolton's samples and Korean normal samples. The number of patients showing maxillary deficiency was larger than that of patients showing maxillary excess in view of true anterior discrepancies. There was a significant difference between anterior Bolton discrepancy from pre-treatment models and true anterior discrepancy from set-up models (p < 0.05) There was no significant difference in true anterior discrepancies among malocclusion groups (p > 0.05). And there was also no significant difference between the male and female groups (p> 0.05). Overbite and the incisal edge thickness of maxillary anterior teeth have little relationship with true anterior discrepancies. Multiple regression analysis showed that true anterior discrepancy was mainly determined by anterior Bolton ratio, upper incisor to occlusal plane angle after treatment. interincisal angle after treatment. and upper right lateral incisor width.

AN ANALYSIS OF STRESS DISTRIBUTION AROUND THE IMPLANT ACCORDING TO THE BONE QUALITY AND BITE FORCE: FINITE ELEMENT METHOD (저작압이 임프란트 주위골 내 응력분포에 미치는 영향에 관한 연구)

  • Hyun Ki-Bong;Lee Sun-Hyung;Chang Ik-Tae;Yang Jae-Ho;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.391-409
    • /
    • 2001
  • Since the early study about the osseointegration, lots of researches have been performed to increase the success rate and the stress around the implant in the jaw bone has been considered as one of the causes of failure. The purpose of this study was to examine the relationship between the implant failure and the stress by analysing the influence of different bone quality and bite force of some foods on the stress distribution around the implant, and to estimate the treatment result according to the bone quality and dietary pattern of patients. Bone quality was divided in 4 groups and models were drawn with the assumption that thread type implant(Nobel Biocare AB, Goteborg, Sweden) of 3.75mm diameter, 13mm length was installed to the bones. Various bite forces were applied to the occlusal surface of superstructure and the stress distributed around the implant were analysed with finite element analysis program. The results were as follows ; 1. The stress was changed proportionally to the bite forces of foods at all measuring points in all load cases. 2. The stress at the marginal bone was higher than that of the other measuring points in all load cases, and it was decreased at the first thread area. 3. The stress at the marginal bone was highest in type IV bone in all load cases. Especially it was twice those of other bone types at the bucco-lingual marginal bone and 50% higher at the mesio-distal marginal bone. 4. The stress at the bucco-lingual sides of the bone around the apical portions of implant showed little differences among the bone types, while type IV bone showed lower stress concentration than the other bone types in the mesio-distal sides. 5. Under the buccal oblique load ($15^{\circ}$ ), the stress at the lingual marginal bone was higher than that of buccal marginal bone, and the difference between the two points was almost same regardless of bone types.

  • PDF

FINITE ELEMENT ANALYSIS ON MAXILLARY MOLAR IMPLANT UNDER DIFFERENT C/R RATIO (상악 구치부 임플랜트 보철수복시 치관/치근비에 따른 응력 분포에 대한 유한 요소 분석)

  • Kim, Jin-Ho;Kim, Hyung-Seob;Choi, Dae-Gyun;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.561-573
    • /
    • 2006
  • Statement of the problem: In cases of low bone level in maxilla followed by extraction due to severe periodontitis or enlarged maxillary sinus, crown-root ratio of implant prosthesis will increase. The prognosis of these cases is not good as expected. Purpose : The purpose is to compare stress distribution due to crown-root ratio and effect of splinting between two implants in maxillary molar area under different loads Material and methods: Using ITI($4.1{\times}10$ mm) implant. two finite element models were made(model S: two parallel implants, model A: one of two is 20 degree inclined). Each model was designed in different crown-root ratio(0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it splinted or non-splinted clinical situations. After that, 300 N force was loaded to each model in four ways.(load 1 : middle of occlusal table, load 2 : middle of buccal cusp, load 3 : middle of lingual cusp, load 4 : horizontal load to middle of buccal cusp), and stress distribution was analyzed. Results: On all occasions, stress was concentrated on neck of implant near cortical bone. In the case of inclined implant, stress was increased compared with parallel implants. Under load 1, 2, 3, stress was not increased even when crown-root ratio increases, but under load 4, when crown-root ratio increases, stress also increased. And more stress was concentrated under load 1 than load 2, 3. When crown-root ratio was same, stress under load 1, 2, 3 decreased when splinting, but under load 4, stress did not really decrease. Conclusion: Under vertical load, stress distribution related to crown-root ratio did not change. But under horizontal load, stress increased as crown-root ratio increases. Under vertical load, splinting decreased stress but under horizontal load, effect of splinting was decreased as condition of implant changes for the worse such as increase of crown-root ratio, inclined implant.

FINITE ELEMENT ANALYSIS OF WIDE DIAMETER SCREW IMPLANT PLACED INTO REGENERATED BONE (재생된 골에 식립한 넓은 직경의 나사형 임플란트에 대한 유한요소법적 분석)

  • Kim, Su-Gwan;Kim, Jae-Duk;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.248-254
    • /
    • 2005
  • The purpose of this study was to investigate the distribution of stress within the regenerated bone surrounding the implant using three dimensional finite element stress analysis method. Using ANSYS software revision 6.0 (IronCAD LLC, USA), a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The $5.0{\times}11.5-mm$ screw implant (3i, USA) was used for this study, and was assumed to be 100% osseointegrated. And it was restored with gold crown with resin filling at the central fossa area. The implant was surrounded by the regenerated type IV bone, with 4 mm in width and 7 mm apical to the platform of implant in length. And the regenerated bone was surrounded by type I, type II, and type III bone, respectively. The present study used a fine grid model incorporating elements between 250,820 and 352,494 and nodal points between 47,978 and 67,471. A load of 200N was applied at the 3 points on occlusal surfaces of the restoration, the central fossa, outside point of the central fossa with resin filling into screw hole, and the functional cusp, at a 0 degree angle to the vertical axis of the implant, respectively. The results were as follows: 1. The stress distribution in the regenerated bone-implant interface was highly dependent on both the density of the native bone surrounding the regenerated bone and the loading point. 2. A load of 200N at the buccal cusp produced 5-fold increase in the stress concentration at the neck of the implant and apex of regenerated bone irrespective of surrounding bone density compared to a load of 200N at the central fossa. 3. It was found that stress was more homogeneously distributed along the side of implant when the implant was surrounded by both regenerated bone and native type III bone. In summary, these data indicate that concentration of stress on the implant-regenerated bone interface depends on both the native bone quality surrounding the regenerated bone adjacent to implant and the load direction applied on the prosthesis.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL ($Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구)

  • Kim Woo-Young;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

Influence of diameter, length, and platform shape of implant fixture on the stress distribution in and around the screw type implant (나사형 임플란트 고정체의 길이, 직경, 플랫폼 형태에 따른 임플란트와 주위조직의 응력분포)

  • Kang, Ji-Eun;Chung, Hyun-Ju;Ku, Chul-Whoi;Yang, Hong-So
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.277-288
    • /
    • 2002
  • Seven finite element models were constructed in mandible having single screw-type implant fixture connected to the premolar superstructure, in order to evaluate how the length, diameter and platform shape of a screw-type fixture influence the stress in the supporting tissue around fixtures. Each finite element model was varied in terms of length, diameter, and platform shape of the fixture. In each model, 250N of vertical load was placed on the central pit of an occlusal plane and 250N of oblique load placed on the buccal cusp. The stress distribution in the supporting tissue and the other components was analysed using 2-dimensional finite element analysis and the maximum von Mises stress in each reference area was compared. Under lateral loading, the stress was larger at the abutment/fixture interface, and in the crestal bone, compared to the stress pattern under vertical loading. The amount of stress at the superstructure was similar regardless of the length, diameter and platform shape of a fixture. Around the longer fixture, the stress was decreased at the bone crest and subjacent cancellous bone and increased in the cancellous bone area apical to the fixture. Around the wider fixture, the stress was decreased at the abutment/fixture interface, and the bone crest and increased in the cancellous bone area apical to the fixture. Around the fixture having wider platform, less stress was produced at the abutment/fixture interface and the upper part of the cortical bone, compared to the fixture having standard platform. In conclusion, the stress distribution of the supporting tissue was affected by length, diameter, and platform shape of a fixture, and the fixture which was larger in diameter and length could reduce the stress in the supporting tissues at the bone-fixture interface and bone crest area.