The relationship between the discharge characteristics and the superficial layer of MgO in AC PDP

  • Kim, Hee-Joong;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.224-227
    • /
    • 2002
  • The relationship between the discharge aging time and the superficial layer thickness of MgO thin film was investigated in an AC PDP. The discharge characteristics of an AC PDP with the various aging time were evaluated by discharge aging experiments. We find the presence of a superficial lay which is related to the discharge characteristics during aging process. The superficial layer of MgO thin film was observed by Transmission Electron Microscope (TEM). It was found that the superficial layer thickness of MgO was dependent on discharge aging time.

  • PDF

Hollow cathode discharge에서 자발적 진동의 광검류 신호 측정 (Observation of spontaneous oscillation of optogalvanic signal in a hollow cathode discharge)

  • 이준회
    • 한국진공학회지
    • /
    • 제12권1호
    • /
    • pp.51-54
    • /
    • 2003
  • 아르곤 방전 기체의 음 글로우 영역에서 자발적 직동의 광검류 신호를 관찰하였다. 자발적 진동의 광검규 신호는 3 mA 보다 낮은 땅선 전류에서 나타난다. 준안정 준위의 인자 밀도 변화와 1s-2p 전이의 방출 세기를 동시에 측정한 결과, 자발적 진동 신호를 발생시키는 메커니즘 중의 한 가지는 느린 전자의 충돌에 의한 준안정 준위 원자의 단계적 이온화이다.

STD-11 합금공구강과 P-20 초경합금재의 WEDM 특성에 관한 연구 (A Study on the Characteristics of Wire-Cut Electrical Discharge Machining for STD-11 Alloy Steel and P-20 Tungsten Carbide Alloy)

  • 이재명;허성중;김원일
    • 한국정밀공학회지
    • /
    • 제13권1호
    • /
    • pp.22-28
    • /
    • 1996
  • From the experimental study of Wire-Cut Electric Discharge Machining of STD-11 alloy steel and P-20 tungsten carbide, the characteristics such as hand drum form and discharge gap have been observed and evaluated for various conditions. Hand drum form can be improved when gap have been observed and evaluated for various conditions. Hand drum form can be improved when gap voltage and spark cycle become smaller, thickness become thinner, wire tension become larger and the no of cutting increases. When 60mm thickness tungsten carbide is cut in normal condition, hand drum form becomes larger due to the low conductivity machining allowance become slightly larger when peak discharge current and gap voltage become larger, or wire tension becomes smaller. Under the same condition, machining allowance of tungsten carbide is larger than alloyed steel by 1/100mm.

  • PDF

The effect of the cell size on the discharge characteristics of a plasma display panel

  • Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • 제12권1호
    • /
    • pp.29-35
    • /
    • 2011
  • In this study, plasma display panels with three different cell volumes were prepared by changing the spaces between the vertical barrier ribs into two and three times the reference structure. The discharge gap and area of the segmented ITO electrode were the same for the three cases, and Ne.20%Xe gas was used. The luminance and luminance efficiency were measured using applied voltage variations. The time evolution and intensity distribution of the infrared, which are related to the vacuum ultraviolet, were observed via intensified, charged, coupled device, and the visible-light intensity profiles were observed using PR-900 to analyze the discharge phenomena in the discharge cell.

Effects of Panel Temperature on the Discharge Characteristics of Micro Discharge Cells

  • Shim, Kyung-Ryeol;Park, Chung-Hoo;Lee, Ho-Jun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.215-219
    • /
    • 2004
  • The effects of ambient temperature on the discharge characteristics of Ne-Xe based micro discharge cells for ac-PDP (plasma display panel) have been studied. In ramp voltage driving, which is generally used as a reset method of PDP, two dissimilar modes of strong and weak discharge were found. As the interval between the former sustaining discharge and ramp voltage discharge becomes greater, the probability of a strong discharge increases. This suggests that a sufficient number of priming particles is necessary for initiating weak mode (Townsend discharge). It was discovered that under higher ambient temperatures, weak discharge occurs more frequently. The discharge time lag observed in square pulse driving of single cells becomes surprisingly smaller under higher ambient temperatures for the constant gas number density condition.

소하천수계의 단위유량도 유도 및 비교에 관한 수문학적 고찰 (Hydrological Studies on the Comparison and the Derivation of Unit Hydrography in the small River Systems.)

  • 이순혁
    • 한국농공학회지
    • /
    • 제20권3호
    • /
    • pp.4739-4749
    • /
    • 1978
  • This studies were conducted to derive synthetic unitgraphs and triangular unitgraphs correlated with watershed characteristics which can be used to the estimation and control of flood for the rational development of Agricultural water resources. Derived Synthetic unitgraphs and Triangular unitgraphs can be applied to the ungaged watersheds were compared with average unitgraphs by observed data. Seven small watersheds were selected as studying basins Han, Geum, Nakdong, Yeongsan and Inchon river system. The results summarized for these studies are as follows: 1. Average unitgraphs by observed data and dimensionless unitgraphs for synthesis were derived for all river systems. 2. Peak discharge per unit area of the unitgraph, qp, was derived as qp=10-0.389-0.0424Lg with a high significance. 3. Formulas for the base width of unitgraph of 50 and 75 percent for peak flow for each water systems was adopted as Table 5. 4. The base length of the unitgraph, Tb, in hours in connection with time to peak, Tp, in hours was expressed as Tb =4.3Tp. 5. Peak discharge, Qp, were obtained as Table 6 by the Triangular form to all subwatersheds. 6. Relative errors in the peak discharge of the synthetic unitgraphs showed to be 7.3 percent to the peak of observed average unitgraphs except errors of peak discharge for Yeongsan river system. This indicates that Synthetic unitgraphs for the small watersheds of Han, Geum, Nakdong and Inchon river systems can be applied to the ungaged watersheds. On the other hand, It was confirmed that the accuracy of Instantaneous Unit Hydrograph with only 1.6 percent as relative errors was approaching more closely to the observed average unitgraph than that of synthetic unitgraph with relative errors. 23.9 percent for Yeongsan river system. 7. Errors in the peak discharge of the triangular unitgraph to the observed average unitgraph showed to be 0.6 percent to 7.5 percent which can be regarded as a high precision within the range of 200 to 500$\textrm{km}^2$ in area. On the contrary, application of triangular unitgraph within the range of 200$\textrm{km}^2$ in area has defined as a unsuitable method because of high relative errors, 26.4 percent to 61.6 percent.

  • PDF

AC PDP(Plasma Display Panel)의 방전 특성 해석

  • 황기웅;정희섭;서정현
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1997년도 제13회 학술발표회 논문개요집
    • /
    • pp.173-176
    • /
    • 1997
  • A numerical analysis of the micro-discharge in an AC pplasma dispplay cell has been made using time-deppendent, 2-dimensional multi-fluid equations to understand the discharge pphysics of He-Xe discharge. The time deppendent distribution of the electron tempperature, densities of electrons, various ions and excited sppecies, and the effects fo the wall charge accumulated on the dielectric surface are obtained and comppared with the results of direct observation of time deppendent behavior of VUV and visible sppectra from single discharge cell observed using a gated, image intensified CCD to elucidate the discharge physics.

  • PDF

Effect of Self-Erase Discharge on the Luminous Efficacy of Long Gap AC PDPs

  • Kim, Tae-Jun;Jung, Jae-Chul;Jung, Hae-Yoon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.585-588
    • /
    • 2007
  • We studied the effect of self-erase discharge on the luminous efficacy of ac PDPs. We observed through discharge current analysis to confirm that the selferase discharge occurred mainly between sustain cathode and address electrode, which have an influence on the luminous efficacy. The amount and timing of the self-erase discharge was varied to observe its effect on the luminous efficacy. It has been found that the luminous efficacy could be improved by the self-erase discharge when it is adjusted to occur right before the main discharge in the small gap structure. In the long gap structure, on the contrary, the luminous efficacy could be increased when the self-erase discharge is suppressed. Also, various waveforms to control self-erase discharge are suggested and tested in the panel experiments.

  • PDF

EFFECTS OF RIVER DISCHARGE ON GROWTH OF PERIPHYTON IN SAND RIVER

  • Toda Yuji;Tsujimoto Tetsuro;Fujimori Noriomi
    • Water Engineering Research
    • /
    • 제6권3호
    • /
    • pp.113-122
    • /
    • 2005
  • Periphyton is known to be one of major primary producers for river ecosystem. While the growth of periphyton usually observed on the stone surface in gravel river, the large growth of periphyton is sometimes seen even in sand river with relatively small river discharge. In the present study, field observations and numerical simulations were performed to investigate the growth of periphyton in sand river. In the field observation, the growth of periphyton on fixed sand bed was measured weekly. The results of the field observations show that the large growth of periphyton occurs in sand river until the bed material sands have not moved. An integrated numerical simulation model is presented to describe the growth of periphyton at observed river reach, and a series of numerical simulations were performed to study the effect of river discharge on growth of periphyton in the sand river. The results of the numerical simulations show that the net primary production of periphyton decreases with the river discharge. These results suggest that the reduction of river discharge at ordinary water stage strongly affects the primary productivity of periphyton even in sand river.

  • PDF

Spatiotemporal Behaviors of Excited Xenon Atoms in a Three-Dimensional Diagnosable Microplasma Unit Cell with High Sustain Frequency for Plasma Display Panels

  • Oh, Jun-Seok;Sakai, Osamu;Hashimoto, Masaki;Tachibana, Kunihide
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.925-928
    • /
    • 2006
  • With the high sustain frequency at 250 kHz, a three-dimensional diagnostics of excited xenon atoms was investigated by the emission and absorption microscopic spectroscopy for plasma display panels, spatiotemporally. As a typical feature of the emissions, a broad discharge peak was observed on the temporal cathode and a sharp one was monitored on the anode, at the high frequency. However, the discharge starts from the cathode edge, actually, that is a discharge space on the floated address (or data) electrode. Spatially, the dense emission and absorption peak were observed in the discharge space between the sustain electrodes gap. Overall, the microdischarge at high sustain frequency showed priming dominant characteristics.