• Title/Summary/Keyword: Observation type

Search Result 1,408, Processing Time 0.028 seconds

Types and Abundance of Filamentous Bacteria, Protozoa and Metazoa in Activated Sludge (활성오니에서 발견된 사상세균, 원생동물 및 후생동물의 유형과 우점도 분석)

  • 정재춘;김남천
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.3
    • /
    • pp.365-371
    • /
    • 1995
  • Filamentous bacteria and other large microorganisms, which are useful indicators of bulking and poeration, were identified by microscopic observation. Activated sludge samples were taken from the aeration basin of 5 municipal wasterwater plants and 6 industrial ones. Among the filamentous bacteria founds, Microthrix parvicella was most frequently present, followed by type 0041, type 1701 and Nocardia. This frequency of occurrence was similar to those reorted in USA and the Neterland. The morphology of filamentous bacteria observed were generally identical with those previously reported. except type 1701 which had slender filament diameter. Among protozoa, Vorticella was most frequently present, followed by Aspidisca, Opercularia and Difflugia. Philodina was the only metazoa observed. Both filamentous bacteria and protozoa would be useful indicator organisms. The potential for these organisms as indicators were discussed.

  • PDF

Determinants and Processes of Morphological Transformation of Apartment Complexes in Busan (부산 아파트 단지 배치형태 변화의 요인과 과정에 관한 연구)

  • Lee, Sangjin;Park, SoHyu
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.3
    • /
    • pp.91-102
    • /
    • 2019
  • This study explores the causes and processes of morphological transformation of apartment complexes in Busan. All apartment complexes built until the year 2016 were selected for statistical analysis, drawing/map examination, field observation, selected expert interviews based on 6 periodical groups: Period I(~1990), Period II(1991~1995), Period III(1996~2000), Period IV(2001~2005), Period V(2006~2010), and Period VI(2011~2016). The research argues for three 'arrangement' types, P1U, L1U and P2U, which have dominated the whole periods occupying 88% of the total 260 complexes. The switch of the leading type represents for morphological transformation of apartment complexes. Four aspects, density(F.A.R.), height(maximum number of floors), deformed-building-type ratio, and building-orientation, have affected the change of 'arrangement' types. Density was the major cause of the arrangement-type switch, from P1U to L1U, on Period II(1991~1995). The morphological change, from type L1U to P2U, on Period V(2006~2010) was caused by height and orientation, and is correlated with the increased number of deformed-type buildings. The first phase morphological change on Period II(1991~1995) was resulted by the supply side of apartment. However, the second phase transformation on Period V(2006~2010) had gone through the complex process including reflection of consumers' demands. The significance of research is to reveal the morphological transformation process of apartment complexes through analytical investigation of the entire apartment data in Busan. The result shows that the major change of urban paysage started to occur from Period V(2006~2010), and the superficial evaluation on apartment 'being monotonous and repetitive' may not be proper at least from the perspective of town plan.

Living Behavioral Patterns of Single or Spouse Elderly Households and Ubiquitous Home Services for Each Household Type (노인단독가구 유형별 생활행태 특성 및 유비쿼터스 홈 서비스 요소 제안)

  • Kwon, Oh Jung
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.759-778
    • /
    • 2010
  • The purposes of this study were to identify living behavioral patterns in of single or couple elderly households in residential environment, to find out ubiquitous home services for the elders, and finally to suggest the ubiquitous home services according to each household's type. For this study, literature review, field works for ubiquitous home services for the elders, and in-depth interview and observation by 74 elderly participants were conducted. The major findings of the study were as follows: single or spouse elderly households were classified into 8 types according to the combination of their household types, income level, and health status. Among 8 types, 2 types were excluded for final analysis due to small sample size. Living behavioral characteristics of 6 types were analyzed and the behavioral pattern of each type was drawn. Based on this behavioral pattern of each type, ubiquitous home services which meet the needs of each type were suggested. The implications and limitations of this study were also discussed and the suggestions for further studies were recommended.

Susceptibility of Stress Corrosion Crack Initiation of Type 304 SS in Simulated Primary Water Environment of PWR (원전 1차 계통수 모사환경에서 Type 304 스테인리스강의 응력부식균열개시 민감도)

  • Sung-Hwan Cho;Sung-Woo Kim;Jong-Yeon Lee
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.20 no.1
    • /
    • pp.25-31
    • /
    • 2024
  • The core shroud of rector vessel internals (RVI) of OPR1000 and ARP1400 is made of Type 304 stainless steel (SS) by bending and welding process that may induce high deformation and residual stress in manufacturing. This work aims to evaluate the susceptibility of stress corrosion crack (SCC) initiation of bent parts of RVI in high temperature primary water environment. For SCC initiation test, tensile specimens were fabricated from the 90 degree bent plate of Type 304 SS (DT specimen), that is an archived part of a Korean APR1400. After the SCC initiation test, the specimen surface was thoroughly examined by optical and scanning electron microscopy, and compared to the specimen fabricated from the as-received plate of Type 304 SS (AR specimen). The surface observation revealed that SCC initiated on the AR specimen surface in typical intergranular (IG) mode, while SCC on the DT specimen occurred in transgrannular mode as well as IG mode. It was also found that the size and number of SCC on the DT specimen were larger than that on the AR specimen. This was attributable to a strain-hardening during the bending process. To compare the susceptibility of SCC initiation, total crack density (TCD) was calculated from the total crack length divided by the measured area of AR and DT specimens. TCD of DT specimen was 4.6 times higher than AR specimen in average, indicating that higher possibility of degradation of bent parts of RVI for a long-term operation.

The Effect of Tin Ion-plating on the Bond Strength of Orthodontic Bracket (TiN Ion-Plating이 교정용 브라켓의 접착강도에 미치는 영향)

  • KIM, Seok-Yong;KWON, Oh-Won;KIM, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.157-171
    • /
    • 1997
  • This study was conducted to see the effect of TiN ion-plating on the bond strength of orthodontic bracket. Three stainless-steel brackets with different base types were chosen; when TiN ion-plated brackets and non iorrplated brackets were bonded to the teeth, initial and long-term bond strength were measured, The observations oi bonding surface and failure sites through the scanning electron microscope were analysed and compared. The summary of this study was as follows; ${\cdot}$ When TiN ion-plating was not applied, the Micro-Loc type was the highest in bond strength atter 24 hours as $5.89{\pm}1.77$ MPa, followed by $4,27{\pm}1.12MPa$ for Foil Mesh type and $2.64{\pm}0.58MPa$ for Undercut type(P<0.05). ${\cdot}$ Under TiN ion-plating, the bond strength after 24 hours showed: Micro-Loc type $-6.26{\pm}1.51MPa$, Foil Mesh type $-7.45{\pm}2.01MPa$, Undercut type $-2.93{\pm}0.84MPa$. Unlike in the case of non ion-plating, Foil Mesh type showed a higher strength than Micro-Loc type, with Undercut type still showing the lowest bond strength(P<0.05). The bond strength, after 24 hours, increased in case of ion-plated in all 3 types, but a significant increase was shown only in Foil Mesh type(P<0.001). ${\cdot}$ Under a long-term immersion, regardless of ion or non ion-plating, bond strength in general increased over the initial bond strength(one day), with more stability. ${\cdot}$ Through scanning electron microscopic observation of bonding surface, it was found that, regardless of the bracket base type or the application of ion-plating, the resin was thoroughly spreaded into bracket base to form a solid bonding surface between the bracket and the tooth. This was also true in case of a long-term immersion. ${\cdot}$ The scanning electron microscopic observation of failure sites revealed diverse failure patterns.

  • PDF

The Effects of Gypsum Fibrosum on Renal Functional and Histopathological Disorder in Chronic Renal Failure Rat Model (석고(石膏)가 만성 신부전 Rat의 신기능 보호 및 조직학적 변화에 미치는 영향)

  • Byun, Sang-Hyuk
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.871-886
    • /
    • 2008
  • Objective : Gypsum fibrosum has been traditionally used in treatment of febrile diseases and recently been shown to have anti-inflammatory effect. Chronic renal failure has a serious clinical symptoms including proteinuria, azotemia, anemia, and hyperlipidemia and has characteristic histopathological changes, glomerular hypertrophy, infiltration of inflammatory cells, and crescentic sclerosis, We investigated the effects of gypsum fibrosum on renal functional and histopathological disorder in chronic renal failure rat model induced 5/6 nephrectomy. Methods : Using Sprague-Dawley rats, CRF was induced by 5/6 nephrectomy. The rats were divided into 3 groups, normal, conrol, and gypsum administered orally with gypsum fibrosum 500mg/kg/day. Body weight, 24 hr proteinuria, hematologic analysis, and histological morphologic changes were followed up after 8 weeks. The glomerular macrophage/monocyte infiltration, $TGF-{\beta}_1$, type IV collagen, and angiotensin II type1 receptor($AT_1$) were evaluated by immunohistochemistry. Resuls : In the CRF control group, functional parameters and histopathologic changes clearly indicated the development of CRF. 24 hr proteinuria significantly increased in the CRF control group over the normal group, and serum creatinine level was lower in the gypsum group than in the control group, LDL-cholesterol was significantly lower in the gypsum group than in the control group. Morphological investigations showed a variety of characteristic features of CRF, glomerular hypertrophy, increasing cellular density of glomerulus, deposition of extra-cellular matrix, fibrotic change, and glomerular sclerosis in the control group, but in the gypsum group, these features diminished significantly. In observation of renal type IV collagen and $AT_1$ expression, positive area significantly increased in the control group over the normal group, and it significantly decreased in the gypsum group compared to the control group. Conclusions : Our findings suggest that gypsum fibrosum inhibits $AT_1$ and type IV collagen expression in renal tissues and attenuates progression of glomerulosclerosis and interstitial fibrosis in chronic renal failure rats, which lead to amelioration of renal function. From these results, we suggest that gypsum fibrosum may have renoprotective effects and could be a useful remedy agent for treating chronic renal failure.

  • PDF

Correction Coeffecient for Tensile Adhesive Strength of the Bridge Decks Waterproofing Systems with Different Temperature Conditions (온도조건에 따른 교면방수재의 인장접착강도 보정계수에 관한 실험적 연구)

  • Lee, Byung-Duck;Yun, Byung-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.794-797
    • /
    • 2004
  • In this study, tensile adhesive strength(TAS) test was carreid out for evaluated the effects of temperature conditions (-20, -10, 0, 5, 10, 20, 30, $40^{\circ}C$) on the tensile adhesive characteristics about 4 type waterproofing membranes which were commercially used in bridge decks. And, failure appeariences of waterproofing systems in each temperature after TAS test were observed the sawing surfaces of waterproofing systems for whether or not damaged of waterproofing membranes. Also, correction coefficient of TAS with temperature were calculated using 4 type waterproofing membrane. It could be shown that the higher TAS and shear adhesive strength, the lower temperature, regardless of the type of waterproofing membrane. Temperature sensibility of TAS was especially remarkable in epoxy membrane. Failure type was occurred the ductile failure in $30^{\circ}C\;and\;40^{\circ}C$. From these results, it was shown that if ambient temperature above $30^{\circ}C$ maintains for a long time, waterproofing membrane will be deformed by softening. Otherwise, waterproofing membrane in temperature below $20^{\circ}C$ shown that occurred the brittle failure. From the results of visual observation of cutting surface for specimen, the thin waterproofing membranes shown indented by hot aggregate of the asphalt mixtures. Therefore, it could be known that the specification of waterproofing membrane thickness is necessary by waterproofing membrane type. As temperature change varied with pavement depth, the interface temperature was more important than ambient temperature in TAS test. Now, TAS test results were limited only in $-10^{\circ}C\;and\;20^{\circ}C$ temperature, but correction coefficient of TAS by ambient temperature could be used as a solution to deal with this problem.

  • PDF

A study on the Healing Effects of UV-Day light for the healthy Leprosy Center through the ANOVA statistical analysis - Focused on 5S (Sort, Straighten, Shine, Standardize, Sustain)

  • Shaikh, Javaria Manzoor;Park, JaeSeung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.4
    • /
    • pp.7-18
    • /
    • 2013
  • Purpose: The aim of this paper is to reduce the stress and the disturbance occur in selective action of patient. This article will also help us to control spreading and reduce the order and bacteria produced by leprosy disease among the lepers. This will be achieved with the help of several variables and these variables help us on health benefits is 5S (Sort, Straighten, Shine, Standardize, Sustain) i.e. ratio of sectional morphology, lessor 90 degree angles, day light, universal design building and maximum ventilation. The replies from the questionnaire were collected based on varying levels of satisfaction and gloominess on the scale of 1-10. Methods: The multi-layer methodological framework for maximising the healing environment obtained from the observation of schemes and parameters of ANOVA: (Analysis Of Variance between five deciding factors) are. Firstly applied for the calculation of the patient's satisfaction for U.V light from sun on ECOTECT simulation, secondly the number of $90^{\circ}$ angle, along the corridors. Thirdly understanding the ways to represent people's perceptual structures and way finding with Space Syntax software. Fourthly the ratio of depth to height of the building typology and finally interviewing the subjects describing their special experiences based on scale value. The focus of this testing of human subjects was to receive data for the existence of image scheme in way-finding and to identify the mechanisms by which sun light impacts human (lepers) health. Results: AMPVA studies concluded that there is similarity between I and O plan as well as L and H plan whereas U plan was difference among the five selected architectural shapes. Implications: The purpose of this research is to show the effects of the I-type, L-type, C-type, U-type and O-type plan design, and to analyse the morphology for EBD (Evidence-Based Design) healing environment which is a universal design for Munghopir Karachi, in Pakistan.

Exhibition Space Characteristics that Reflect the Expression Type of Interaction Design - Centered in Digital Media Exhibition Space of Seoul City - (인터랙션 디자인 표현유형을 반영한 전시공간 특성 - 서울지역 디지털미디어 전시공간을 중심으로 -)

  • Kim, Kyoung-Tae;Han, Hae-Ryon
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.5
    • /
    • pp.55-62
    • /
    • 2016
  • This study was to research and study whether the types of interaction design perform the effective functions and roles as the exhibition space that audiences want centered in the digital media exhibition space. It was to suggest effective space characteristics through analyzing how the interaction design was expressed at the exhibition space and its application. For the analysis, it completes theoretical inquiry on the classification of the space characteristics according to the concept type of interaction and design characteristics. Based on it, it directly visited the exhibition space that reflected the interaction design centered in Seoul City, experienced the given experience, and designed the analyzing frame by composing a checklist after the observation research. Through the designed analysis, it performed a site questionnaire to audiences. It induced the conclusion as follows after analyzing the case space that reflected the interaction design type. First, the program analysis of the space that has the variability is necessary through a variety of digital analysis as there is a limitation that the characteristic of digital media has. Second, in the concept type of the interaction design, it needs the interaction stage among people that can communicate with audiences and stimulate their senses through vidual factors. Third, in the characteristic of the interaction design, it should try to use effective contents to get over the limitation of the space through the interaction in the designated space in case of exhibition. In the following research, it needs to study on the variety of stage plans in detail by supplying contents to audiences and grafting to the exhibition space continuously through using the interaction design that uses digital media at there.

Observation of the Preionization effect and Operational Characteristics of a Nitrogen Laser by a Pulse type high Voltage Power Supply (펄스형 고전압 전원에 의한 선전리 현상의 관측과 질소레이저의 동작 특성)

  • Lee, Bong-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2006
  • We constructed a TEA $N_2$ laser which consists of spark gap, pulse type high voltage power supply, Blumlein transmission line circuit, laser tube with Ernst electrode. We observed the self-preionization with an optical fiber in the spark gap and laser tube. The higher voltage power supplied to the Blumlein transmission line circuit, the better preionization was. An U-type transformer yielded better stability and output power than an I-type transformer. The discharge time after triggering a spark gap for the U-type transformer was also short. We obtained the stability of $2.7\%$ and output power of $36{\mu}J$ when the optimum conditions of the laser operation were spark gap distance of 6.0 mm, electrode distance in laser tube of 5.0 mm, $N_2$ gas flow rate in spark gap of 1500 cc/min, $N_2$ gas flow rate in laser tube of 4 ${\iota}$/min, output window reflectivity of $40\%$ and repetition rate of 10 Hz.