• Title/Summary/Keyword: Oblique view

Search Result 86, Processing Time 0.033 seconds

Utility of forward-view endoscopic ultrasound in fine-needle aspiration in patients with a surgically altered upper gastrointestinal anatomy

  • Asmaa Bakr;Kazuo Hara;Moaz Elshair;Shin Haba;Takamichi Kuwahara;Nozomi Okuno;Daiki Fumihara;Takafumi Yanaidani;Samy Zaky;Hanaa Omar
    • Clinical Endoscopy
    • /
    • v.56 no.3
    • /
    • pp.367-374
    • /
    • 2023
  • Background/Aims: Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) using oblique-view EUS in patients with a surgically altered anatomy (SAA) of the upper gastrointestinal tract is limited because of difficult scope insertion due to the disturbed anatomy. This study aimed to investigate the efficiency of forward-view (FV)-EUS in performing FNA in patients with a SAA. Methods: We retrospectively investigated 32 patients with a SAA of the upper gastrointestinal tract who visited Aichi Cancer Center Hospital in Nagoya, Japan, between January 2014 and December 2020. We performed upper gastrointestinal EUS-FNA using FV-EUS combined with fluoroscopic imaging to confirm tumor recurrence or to make a decision before chemotherapy or after a failure of diagnosis by radiology. Results: We successfully performed EUS-FNA in all studied patients (100% technical success), with the specificity, sensitivity, and accuracy of 100%, 87.5%, and 87.8%, respectively, with no complications. Conclusions: EUS-FNA using FV-EUS combined with fluoroscopic imaging is an effective and safe technique for tissue acquisition in patients with a SAA.

Analysis of sideward footprint of Multi-view imagery by sidelap changing (횡중복도 변화에 따른 다각사진 Sideward Footprint 분석)

  • Seo, Sang-Il;Park, Seon-Dong;Kim, Jong-In;Yoon, Jong-Seong
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.53-56
    • /
    • 2010
  • An aerial multi-looking camera system equips itself with five separate cameras which enables acquiring one vertical image and four oblique images at the same time. This provides diverse information about the site compared to aerial photographs vertically. However, multi-looking Aerial Camera for building a 3D spatial information don't use a large-size CCD camera, do uses a medium-size CCD camera, if acquiring forward, backward, left and right imagery of Certain objects, Aerial photographing set overlap and sidelap must be considered. Especially, Sideward-looking camera set up by the sidelap to determine whether a particular object can be acquisition Through our research we analyzed of sideward footprint and aerial photographing efficiency of Multi-view imagery by sidelap changing.

  • PDF

Evaluation of Radiation Dose and Imaging of the QC Program in Mammography MLO View (MLO View의 유방촬영에서 QC 프로그램을 이용한 선량 및 영상 평가)

  • Lee, Seon-Hwa;Kim, Jung-Min;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.221-228
    • /
    • 2015
  • Purpose: In digital mammography QC program was used for the purpose of reducing low-dose and high-definition images of the radiation dose. Materials and Methods: In digital mammography using a QC phantom according to the average glandular dose in the exposure method MLO view $0^{\circ}C$, $30^{\circ}C$, $45^{\circ}C$, $50^{\circ}C$, $55^{\circ}C$, $70^{\circ}C$, was measured at $90^{\circ}C$ intervals, an image with Hologic QC program to the SNR and CNR was measured to evaluate. Results: The average dose in the MLO view was wired to $90^{\circ}C$ when the maximum was 1.75 mGy, it decreased approximately 6% was measured at $45^{\circ}C$ 1.65 mGy. In addition, 1.67 mGy, manual record, there were an average wired in accordance with the exposure dose and the dose of 1.52 mGy difference in the way auto filter. Image quality evaluation at every angular section SNR 50 ~ 52, shows a slight difference in CNR 11 ~ 12, it was included in the manufacturer's recommended value. Conclusion: The dose was lowest in MLO view $45^{\circ}C$, the difference between SNR and CNR were insignificant. The method of exposure will need a way to reduce the exposure of the patient's body or unnecessary patient by placing a difference in settings in which the characteristics.

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

Mathematical Model Identification and Optimal Navigation Control for Automatic Navigation of Underwater Vehicle (수중운동체의 자율운항을 위한 수학모델 확립과 최적운항 제어기법)

  • Kim, Jong-Hwa;Son, Kyeong-Ho;Kong, Gil-Yeong;Lee, Seung-Geon
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.216-217
    • /
    • 2005
  • This paper presents an integrated navagation control concept for underwater vehicles under high speed navigation circumstance. First of all, in order to control an underwater vehicle with respect to automatic navigation, an integrated navigation control method is suggested in view of synchronous control for course keeping, diving and depth control. An exact nonlinear model equation with six-degree-of-freedom is derived for control algorithm. To identify various hydrodynamic coefficients of the equation, an experimental approach is introduced and results are demonstrated for MANTA type model.

  • PDF

Apicoectomy for Treatment of Periapical Abscess in two Dogs (치근단 주위 농양의 치료로서 치근단 절제술 적용 2례)

  • 이은창;김희영;이충호;정성목;박성민;김완희;양정환;유준호;홍연정
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.253-255
    • /
    • 2002
  • A 10-year-old, female mixed breed dog and a 3-year-old, female chihuahua which had swelling below lower eyelid were refered to Veterinary Medical Teaching Hospital, Seoul National University. The plain maxillary oblique view revealed radiolucency at periapical area in maxillary fourth premolar. The 2 cases were diagnosed as periapical abscess by clinical sign and radiographs, and apicoectomies were performed for resetting the lesions and preserving the teeth. Under general anesthesia with isoflurane, periapical abscess was resected by burs and the defect was filled with zinc phosphate cement. Radiograph was perfomed at 1 week and 1 year after apicoectomy and there was no evidence of recurrence.

Study of Ultra-Small Optical Anisotropy Profile of Rubbed Polyimide Film by using Transmission Ellipsometry

  • Lyum, Kyung Hun;Yoon, Hee Kyu;Kim, Sang Jun;An, Sung Hyuck;Kim, Sang Youl
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.156-161
    • /
    • 2014
  • Anisotropy profile of a rubbed polyimide film is investigated using both a modified ultra high precision transmission ellipsometer and the analysis software previously developed to determine the optic axis distribution of discotic liquid crystals in the wide view film. The distorted sinusoidal variation of the ellipsometric constants obtained at an oblique angle of incidence indicates that the optic axis varies from $14.7^{\circ}$ to $40.6^{\circ}$ from the sample plane. The magnitude and distribution of anisotropy is expressed in terms of no, ne, and the cosine-shaped tilt angle distribution of the optic axis in a rubbed polyimide film.

A Study on Muscular System of Foot Three Yang Meridian-Muscle (족삼양경근(足三陽經筋)의 근육학적(筋肉學的) 고찰(考察))

  • Lee, Myung-Sun;Hong, Seung-Won;Lee, Sang-Ryong
    • Korean Journal of Acupuncture
    • /
    • v.25 no.2
    • /
    • pp.1-32
    • /
    • 2008
  • Objectives : This study was performed to understand the interrelation between 'Foot three yang meridian-muscle' and 'muscular system'. Methods : We have researched some of the literatures on Meridian-muscle theory, anatomical muscular system, myofascial pain syndrome and anatomy trains. And especially we have compared myofascial pain syndrome to anatomy trains and researched what kind of relationship is exist between them. Results : It is considered that Foot taeyang meridian-muscle includes Abductor digiti minimi m., Gastrocnemius m., Biceps femoris m., Longissimus m., Omohyoid m., Occipital m., Frontal m., Orbicularis oculi m., Trapezius m., Sternocleidomastoid m., Sternohyoid m., Zygomaticus m. Foot soyang meridian-muscle includes Dorsal interosseus m., Tendon of extensor digitorum longus m., Extensor digitorum longus m., Iliotibial band, Vastus lateralis m., Piriformis m., Tensor fasciae latae m., Internal abdominal oblique m., External abdominal oblique m,, Internal intercostal m., External intercostal m., Pectoralis major m., Sternocleidomastoid m., Posterior auricular m., Temporal m., Masseter m., Orbicularis oculi m. Foot yangmyung meridian-muscle includes Extensor digitorum longus m., Vastus lateralis m., Iliotibial band, Iliopsoas m., Anterior tibial m., Rectus femoris m., Sartorius m., Rectus abdominis m., Pectoralis major m., Internal intercostal m., External intercostal m., Sternocleidomastoid m., Masseter m., Levator labii superioris m., Zygomatic major m., Zygomatic minor m., Orbicularis oculi m., Buccinator m. and the symptoms of Foot three yang meridian-muscle are similar to the myofascial pain syndrome. Superficial back line in anatomy trains is similar to the pathway of Foot taeyang meridian-muscle. Lateral Line in anatomy trains is similar to the pathway of Foot soyang meridian-muscle. Superficial Front Arm Line in anatomy trains is similar to the pathway of Foot yangmyung meridian-muscle. Conclusions : There is some difference between myofascial pain syndrome and meridian-muscle theory in that the former explains each muscle individually, while the latter classifies muscular system in the view of integrated organism. More studies are needed in anatomy and physiology to support the integration of muscular system of Foot three yang meridian-muscle in aspect of anatomy trains.

  • PDF

Interaction of Ion Cyclotron Electromagnetic Wave with Energetic Particles in the Existence of Alternating Electric Field Using Ring Distribution

  • Shukla, Kumari Neeta;Kumari, Jyoti;Pandey, Rama Shankar
    • Journal of Astronomy and Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.67-77
    • /
    • 2022
  • The elements that impact the dynamics and collaborations of waves and particles in the magnetosphere of planets have been considered here. Saturn's internal magnetosphere is determined by substantiated instabilities and discovered to be an exceptional zone of wave activity. Interchanged instability is found to be one of the responsible events in view of temperature anisotropy and energization processes of magnetospheric species. The generated active ions alongside electrons that constitute the populations of highly magnetized planets like Saturn's ring electron current are taken into consideration in the current framework. The previous and similar method of characteristics and the perturbed distribution function have been used to derive dispersion relation. In incorporating this investigation, the characteristics of electromagnetic ion cyclotron wave (EMIC) waves are determined by the composition of ions in plasmas through which the waves propagate. The effect of ring distribution illustrates non-monotonous description on growth rate (GR) depending upon plasma parameters picked out. Observations made by Cassini found appropriate for modern study, have been applied to the Kronian magnetosphere. Using Maxwellian ring distribution function of ions and detailed mathematical formulation, an expression for dispersion relation as well as GR and real frequency (RF) are evaluated. Analysis of plasma parameters shows that, proliferating EMIC waves are not developed much when propagation is parallelly aligned with magnetosphere as compared to waves propagating in oblique direction. GR for the oblique case, is influenced by temperature anisotropy as well as by alternating current (AC) frequency, whereas it is much affected only by AC frequency for parallel propagating waves.