• Title/Summary/Keyword: Oblique Line

Search Result 100, Processing Time 0.026 seconds

Counterbalance applied to the Dynamics of Daniel Libeskind's Architecture - Focused on Libeskind Museums - (다니엘 리베스킨트 건축의 역동성에 적용된 상대적 균형감 - 뮤지엄 건축을 중심으로 -)

  • Lee, Da-Kyoung;Cho, Ja-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.1
    • /
    • pp.64-71
    • /
    • 2015
  • This study aims to disclose the dynamics of Daniel Libeskind Museums by the principles of counterbalance. Balance as a dynamic concept is the settlement of instability and tension and to draw overall sense of balance by controlling new perception elements that may cope with the unbalance elements. This is based on balancing compensation and can be explained as a counterbalance. Daniel Libeskind, a representative architect of deconstructivism, creates dynamic space by using oblique lines on the plane. The study was carried out under the assumption that this space would be designed under the certain principles rather than the result of momentary feelings and the analysis was conducted by the counterpoint of music and counterbalance. As a result, Daniel Libeskind balances in a way of forming the mutual right angle by using oblique lines which cancel out the unbalance in plane composition or making the same angle based on vertical / horizontal axis. Counterbalance has been achieved in the section and elevation as well as plane and complex and diverse oblique lines were worked under the constant principle not accidental results. The axes of Daniel Libeskind's architecture have been known to follow contextualism with symbolism and historicity but it was found that a design technique considering counterbalance was used in the overall control.

Numerical prediction analysis of propeller exciting force for hull-propeller-rudder system in oblique flow

  • Sun, Shuai;Li, Liang;Wang, Chao;Zhang, Hongyu
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.69-84
    • /
    • 2018
  • In order to analyze the characteristics of propeller exciting force, the hybrid grid is adopted and the numerical prediction of KCS ship model is performed for hull-propeller-rudder system by Reynolds-Averaged Navier Stokes (RANS) method and volume of fluid (VOF) model. Firstly, the numerical simulation of hydrodynamics for bare hull at oblique state is carried out. The results show that with the increasing of the drift angle, the coefficients of resistance, side force and yaw moment are constantly increasing, and the bigger the drift angle, the worse the overall uniformity of propeller disk. Then, propeller bearing force for hull-propeller-rudder system in oblique flow is calculated. It is found that the propeller thrust and torque fluctuation coefficient peak in drift angle are greater than that in straight line navigation, and the negative drift angle is greater than the positive. The fluctuation peak variation law of coefficient of side force and bending moment are different due to various causes.

Finite element stress analysis on supporting bone by tripodal placement of implant fixture (유한요소법을 이용한 임플란트 고정체의 삼각배열에 따른 지지골의 응력 분석)

  • Son, Sung-Sik;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: This study was to propose the clear understanding for stress distribution of supporting bone by use of staggered buccal offset tripodal placement of fixtures of posterior 3 crown implant partial dentures. We realized posterior 3 crown implant fixed partial dentures through finite element modeling and analysed stress effect of implant arrangement location to supporting bone under external load using finite element method. Method: To understand stress distribution of 3 crown implant fixed partial dentures which have 2 different arrangement by finite element analysis. In each model, for loading condition, we applied $45^{\circ}$ oblique load to occlusal surface of crown and applied 100 N for 3 crown individually(total 300 N) for imitating possible oral loading condition. at this time, we calculated Von Mises stress distribution in supporting bone through finite element method. Result: When apply $45^{\circ}$ oblique load to in-line arrangement model, maximum stress result for 100 N for each 3 crown 47.566MPa. In tripodal placement, result for 1mm buccal offset tripodal placement implant model was maximum distributed load 51.418MPa, so result was higher than in-line arrangement model. Conclusion: In stress distribution result by placement of implant fixture, the most effective structure was in-line arrangement. The tripodal placement does not effective for stress distribution, gap cause more damage to supporting bone.

  • PDF

The study on preference according to visual shape of Hangeul logotype (한글 로고타입의 시각적인 형태에 따른 선호도에 관한 연구)

  • Shin, Yoon-Jhin
    • Science of Emotion and Sensibility
    • /
    • v.12 no.2
    • /
    • pp.193-204
    • /
    • 2009
  • The importance of corporate identity design has been recently highlighted in the marketing. However, logotype among marks that represent the image of a company has been neglected relatively comparing to symbol mark and logo mark. A logotype should be something to represent the personalities and characteristics of a company in suggestive ways. For such reasons, the image expressions by shape are thought to be important. Consequently, the formative aspects of visual communication design should be examined with emphases. However, it is true that studies on the formative aspects regarding logotypes and logo marks, especially studies on the shapes of font types and the responses of consumers to them, are lacking. Accordingly, this study examined the visual shape of logotype preferred by consumers and the shape of logotype preferred by consumers according to the business type of companies. As a result of research, there were differences in the elements of logotype preferred according to the business type of companies; as for construction companies is preferred the body of the type of dotum font with bold stem, without serif, with oblique, straight-line and curve-line endings; as for banks is preferred the body of the type of dotum font without serif, with oblique ending and with one-side curve style of serif, the stem in a middle level; as for laboratories is preferred the body of the type of dotum font with oblique ending, with bold stem and straight-line serif. The elements that should be commonly applied to construction companies, banks and laboratories appear to be the oblique ending but the curve-line ending and shallow stem seemed to be avoided. On the other hand, the serif, ending and gulim appeared to be applied differently according to the business type.

  • PDF

A STUDY OF DENIAL ARCH FORM IN NORMAL OCCLUSION (정상교합의 치열궁형태에 관한 연구)

  • Cho, Joo-Hwan;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.249-261
    • /
    • 1984
  • This study was to investigate the fitness of the dental arch line to the parabola, and to estimate correlation between the parabola and some ratios of the dental arch measurements. The sample was consisted of the 64 plaster casts showing normal occlusion which was taken from males and females of Korea, aging from 15 to 18 years. The photos of occlusal surface of the plaster casts were taken, and 38 landmarks on the film were selected. The 3 dental arch lines on each dental arch were imaged. One is the dental arch line passing the points of the most buccal surfaces of the teeth, another is that passing the buccal cusp tips of the posterior teeth and the incisal edges, and the other is that passing the midpoints of the teeth. The landmarks on the film were digitized, and measurements and statistics were performed by the IBM computer. The results were as follows; 1. The fitness of the dental arch to the parabola was very good. The fitness of thor upper dental arch was above $91\%$, and that of the lower dental arch was $93\%$. 2. The dental arch line passing the points of the most buccal surfaces of teeth was best fit to the parabola, the buccal cusp tip arch line and the midpoint arch line in order. 3. Correlation between the ratio of oblique molar dental height to molar width and the parabola was very high. 4. The ratio of oblique molar dental height to molar width was devided into 4 groups by the quartiles, and mean parabolic equations and curves were calculated and drawn.

  • PDF

Comparison for the Metatarso-Phalangeal Oblique Angle in the Diabetic Foot (당뇨 족 환자간에 중족 족지 관절 경사각의 비교)

  • Kim, Jae-Hwa;Cho, Duck-Yun;Yoon, Hyung-Ku;Shin, Dong-Eun;Lee, Jae-Man
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.139-143
    • /
    • 2002
  • Purpose: We analyzed the Metatarso-Phalangeal Oblique Angle(MPOA) of Diabetic foot. Materials and methods: We studied retrospectively 60 cases of diabetic foot in 52 patients, for the evaluation of the correlations between clinical outcomes and radiologic findings in the conservative management group (Group A; 36 cases) and the major operation group (Group B; 24 cases). We measured MPOA on AP view. The MPOA was defined as the intersection angle of the Metatarso-Phalangeal Break Line (a line passing from the second to fifth metatarsal heads) and the long axis of foot in sagittal plane. We performed the statistical analysis between MPOA and clinical outcomes. by independent t-test. Results: The mean of MPOA in group B, $70.79^{\circ}$ (range: $62.8^{\circ}-81.3^{\circ}$), was significantly higher than that in group A, $68.04^{\circ}$ (range: $62.0^{\circ}-76.4^{\circ}$). The mean of MPOA in patients of fore foot lesions(30 cases), $71.30^{\circ}$ (range: $62.0^{\circ}-71.5^{\circ}$), was significantly higher than that in patients of hind foot lesions(30 cases), $66.97^{\circ}$(range: $62.8^{\circ}-81.3^{\circ}$). Conclusions: We recognized the MPOA might be useful simple parameter in assessing the diabetic foot.

  • PDF

A COMPARATIVE STUDY ON THE STANDARDIZED AND INDIVIDUALIZED OBLIQUE LATERAL TRANSCRANIAL RADIOGRAPHS OF THE TEMPOROMANDIBULAR JOINT (규격화 및 개인별 악관절사측방향 투사법에 관한 비교연구)

  • Sohn Young-Soon;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.97-108
    • /
    • 1992
  • The author obtained 120 oblique-lateral transcranial radiograms by two projection methods from 30 subjects with clinically normal TMJ. The relative position of the condyle within the articular fossa and the quality of the radiographic images were compared in the standardized and individualized radiographic groups. The results were as follows: 1. The condylar position in the individualized radiographic group was more posterior than that in the standardized radiographic group (P<0.001). 2. The horizontal angle between the long axis of condyle and intermeatal line in the individualized group ranged from 0° to 31° (14.38°±7.55°), and the highest prevalence was found between 15 and 19° 3. The individualized group showed prominent radiopaque shadow of the anterior condylar border; the image detail was superior in the standardized group to that of the individualized group (P<0.05).

  • PDF

Algorithm for Discrimination of Brown Rice Kernels Using Machine Vision (기계시각을 이용한 현미의 개체 품위 판별 알고리즘 개발)

  • 노상하;황창선;이종환
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.295-302
    • /
    • 1997
  • An ultimate purpose of this study was to develop an automatic system for brown rice quality inspection using image processing technique. In this study emphasis was put on developing an algorithm for discriminating the brown rice kernels depending on their external quality with a color image processing system equipped with an adaptor magnifying the input image and optical fiber for oblique lightening. Primarily, geometical and optical features of images were analyzed with paddy and the various brown rice kernel samples such as a sound, cracked, peen-transparent, green-opaque, colored, white-opaque and brokens. Secondary, geometrical and optical parameters significant for identifying each rice kernels were screened by a statistical analysis(STEPWISE and DISCRIM procedure, SAS wer. 6) and an algorithm fur on- line discrimination of the rice kernels in static state were developed, and finally its performance was evaluated. The results are summarized as follows. 1) It was ascertained that the cracked kernels can be detected when e incident angle of the oblique light is less than 2$0^{\circ}C$ but detectivity was significantly affected by the angle between the direction of the oblique light and the longitudinal axis of the rice kernel and also by the location of the embryo with respect to the oblique light. 2) The most significant Parameters which can discriminate brown rice kernels are area, length and R, B and r values among the several geometrical and optical parameters. 3) Discrimination accuracies of the algorithm were ranged from 90% to 96% for a sound, cracked, colored, broken and unhulled, about 81 % for green-transparent and white-opaque and 75 % for green-opaque, respectively.

  • PDF

A Study on Muscular System of Foot Three Yang Meridian-Muscle (족삼양경근(足三陽經筋)의 근육학적(筋肉學的) 고찰(考察))

  • Lee, Myung-Sun;Hong, Seung-Won;Lee, Sang-Ryong
    • Korean Journal of Acupuncture
    • /
    • v.25 no.2
    • /
    • pp.1-32
    • /
    • 2008
  • Objectives : This study was performed to understand the interrelation between 'Foot three yang meridian-muscle' and 'muscular system'. Methods : We have researched some of the literatures on Meridian-muscle theory, anatomical muscular system, myofascial pain syndrome and anatomy trains. And especially we have compared myofascial pain syndrome to anatomy trains and researched what kind of relationship is exist between them. Results : It is considered that Foot taeyang meridian-muscle includes Abductor digiti minimi m., Gastrocnemius m., Biceps femoris m., Longissimus m., Omohyoid m., Occipital m., Frontal m., Orbicularis oculi m., Trapezius m., Sternocleidomastoid m., Sternohyoid m., Zygomaticus m. Foot soyang meridian-muscle includes Dorsal interosseus m., Tendon of extensor digitorum longus m., Extensor digitorum longus m., Iliotibial band, Vastus lateralis m., Piriformis m., Tensor fasciae latae m., Internal abdominal oblique m., External abdominal oblique m,, Internal intercostal m., External intercostal m., Pectoralis major m., Sternocleidomastoid m., Posterior auricular m., Temporal m., Masseter m., Orbicularis oculi m. Foot yangmyung meridian-muscle includes Extensor digitorum longus m., Vastus lateralis m., Iliotibial band, Iliopsoas m., Anterior tibial m., Rectus femoris m., Sartorius m., Rectus abdominis m., Pectoralis major m., Internal intercostal m., External intercostal m., Sternocleidomastoid m., Masseter m., Levator labii superioris m., Zygomatic major m., Zygomatic minor m., Orbicularis oculi m., Buccinator m. and the symptoms of Foot three yang meridian-muscle are similar to the myofascial pain syndrome. Superficial back line in anatomy trains is similar to the pathway of Foot taeyang meridian-muscle. Lateral Line in anatomy trains is similar to the pathway of Foot soyang meridian-muscle. Superficial Front Arm Line in anatomy trains is similar to the pathway of Foot yangmyung meridian-muscle. Conclusions : There is some difference between myofascial pain syndrome and meridian-muscle theory in that the former explains each muscle individually, while the latter classifies muscular system in the view of integrated organism. More studies are needed in anatomy and physiology to support the integration of muscular system of Foot three yang meridian-muscle in aspect of anatomy trains.

  • PDF

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.