• Title/Summary/Keyword: Oblique Image

Search Result 137, Processing Time 0.031 seconds

Optimization of the surface structure of reflector for reflective LCDs (반사형 LCD용 반사판의 표면구조의 최적화)

  • 김홍철;박원상;황용석;윤태훈;김재창
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.2
    • /
    • pp.166-170
    • /
    • 2002
  • Reflectors for reflective LCDs must be designed to be able to control the direction of the image and the viewing angle range for optimal display. In this paper, we tried to optimize the reflector for reflective LCDs. The conventional surface structures showed many defects and problems. Therefore we made efforts to improve the surface structures of the conventional reflectors through both a theoretical approach and analytic work. As a result, we proposed surface structures which showed almost uniform reflectance within the viewing angle range specified by a user even at any oblique incidence. By using Beckmann's equations, we could check the reflective property of the proposed surface structures.

Analysis of sideward footprint of Multi-view imagery by sidelap changing (횡중복도 변화에 따른 다각사진 Sideward Footprint 분석)

  • Seo, Sang-Il;Park, Seon-Dong;Kim, Jong-In;Yoon, Jong-Seong
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.53-56
    • /
    • 2010
  • An aerial multi-looking camera system equips itself with five separate cameras which enables acquiring one vertical image and four oblique images at the same time. This provides diverse information about the site compared to aerial photographs vertically. However, multi-looking Aerial Camera for building a 3D spatial information don't use a large-size CCD camera, do uses a medium-size CCD camera, if acquiring forward, backward, left and right imagery of Certain objects, Aerial photographing set overlap and sidelap must be considered. Especially, Sideward-looking camera set up by the sidelap to determine whether a particular object can be acquisition Through our research we analyzed of sideward footprint and aerial photographing efficiency of Multi-view imagery by sidelap changing.

  • PDF

Magnetic Resonance Imaging in Thoracic Disease (흉부질환의 자기공명영상)

  • Song, Koun-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.345-352
    • /
    • 1993
  • The role of magnetic resonance(MR) imaging in the evaluation of thoracic disease has been limited Nontheless, MR has inherent properties of better contrast resolution than CT allowing tissue-specific diagnosis. MR has capability of direct imaging in sagittal, coronal, and oblique planes which provide better anatomic information than axial images of CT such as lesions in the pulmonary apex, aorticopulmonary window, peridiaphragmatic region, and subcarinal region. MR is sensitive to blood flow making it an ideal imaging modality for the evaluation of cardiovascular system of the thorax without the need for intravenous contrast media. Technical developments and better control of motion artifacts have resulted in improved image quality, and clinical applications of MR imaging in thoracic diseases have been expanded. Although MR imaging is considered as a problem-solving tool in patients with equivocal CT findings, MR should be used as the primary imaging modality in the following situations: 1) Evaluation of the cardiovascular abnormalities of the thorax 2) Evaluation of the superior sulcus tumors 3) Evaluation of the chest wall invasion or mediastinal invasion by tumor 4) Evaluation of the posterior mediastinal mass, especially neurogenic tumor 5) Differentiation of fibrosis and residual or recurrent tumor, especially in lymphoma 6) Evaluation of brachial plexopathy With technical developments and fast scan capabilities, clinical indications for MR imaging in thorax will increase in the area of pulmonary parenchymal and pulmonary vascular imaging.

  • PDF

Scarf Design Combined with Opt Art and Geometrical Pattern of Traditional Ddeoksal (옵아트와 전통 떡살의 기하문양을 조합한 스카프디자인 연구)

  • Kim, Sun Young
    • Fashion & Textile Research Journal
    • /
    • v.15 no.3
    • /
    • pp.325-335
    • /
    • 2013
  • This work develops a motif design integrated with geometrical patterns in traditional ddeoksal and that can be applied to a scarf design so that traditional elements unique to Korean culture can be developed further for a modern application to various design fields. For the research method, literature reviews on op art and traditional ddeoksal were conducted with Adobe Illustrator CS3 and Adobe Photoshop CS3. As for the motif combination, such applications were taken as five pieces from the works of Victor Vasarely and some traditional ddeoksal shapes such as oblique line pattern, taegeuk pattern, and geometrical pattern. Abstract and geometrical images were borrowed from op art and ddeoksal for image expression. The total number of works selected was eleven. To realize the applied scarf design, a motif layout was performed with the scarf center or rim highlighted so that each design feature could be remarkable based on the motif combination. With the function of scaling, rotation, opacity control, filtering effect, the changed images were shown through motif distortion. In addition, this work applies a single combined motif to products for a possible transformation into handkerchiefs and boutique scarfs in the case of smaller sized scarfs.

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

Three-Dimensional Digital Subtraction Angiography (디지털 혈관 조영술 영상의 3차원적 해석)

  • 이승지;김희찬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.1
    • /
    • pp.63-71
    • /
    • 1983
  • A dye-edge tracking algorithm was used to determine the corresponding points in the two images(anterior-posterior and lateral) of the digital subtraction biplane angiography. This correspondence was used to reconstruct three dimensional images of cerebral artery in a dog experiment. The method was tested by comparing the measured image of oblique view with the computed reconstructed image. For the present study, we have developed three new algorithms. The first algorithm is to determine the corresponding dye-edge points using the fact the dye density at the moving edge avows the same changing pattern in the two projection views. This moving pattern of dye-edge density is computed using a matching method of cross-correlation for the two sequential frames' dye density. The second algorithm is for simplified perspective transformation, and the third one is to identify the specific corresponding points on the small vessels. The present method can be applied to compute the blood velocity using the dye-edge displacement and the three- dimensional distance data.

  • PDF

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

The Study Intervertebral Foramen Image for the Cervical spine of Posterior Anterio Oblique for the Angle (목뼈 척추사이 공간 관찰을 위한 후·전 사방향 촬영 각도에 관한 연구)

  • Ahn, Byung Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • The Study on the patient is in a clinical researcher is not necessarily pose before after before after dwichim (Pronation) pose with neck-in-law (RAO, LAO) to chwalyoungbeop subjective evaluation experiment looked at objectively. Overview evaluation is a result of measuring the angle of the space between the vertebrae in PACS image $C_2{\sim}C_3$, $C_3{\sim}C_4$, $C_4{\sim}C_5$, $C_5{\sim}C_6$, $C_6{\sim}C_7$, in the angle of the $C_7{\sim}T_1$ $47.4^{\circ}{\pm}3.3$, $50.5^{\circ}{\pm}2.3$, $52.7^{\circ}{\pm}4.2$, $53.2^{\circ}{\pm}1.9$, $53.2^{\circ}{\pm}2.3$, $55.2^{\circ}{\pm}2.3$ was found to show increasing the angle between the ball and the median nerve in the lower neck sagittal grows. In a comparison of the measured angles in foraminal image was not significantly different (P>0.01). Subjective evaluation Recever Operation characteristic to the top, the upper neck hole (foramen) C2 ~ C3-up than conventional $45^{\circ}$ angle of the lower neck, $C_3{\sim}C_4$, were observed in the well $50^{\circ}$ $C_5{\sim}C_6$, $C_6{\sim}C_7$, the $C_7{\sim}T_1$ was observed at $55^{\circ}$ well observed experimental results video recession neck vertebrae son-in-law, son-in-law taken place in an objective evaluation, subjective evaluation of the upper neck after case could be observed at $50^{\circ}$, well in the lower neck $55^{\circ}$.

Aesthetic Characteristics of Hanae Mori's Apparel (하나에 모리(Hanae Mori) 의상에 나타난 미적 특성)

  • Choi, Young-Ok
    • Fashion & Textile Research Journal
    • /
    • v.9 no.6
    • /
    • pp.613-625
    • /
    • 2007
  • Globalizing the Japanese fashion successfully, Hanae Mori's work awoke the western fashion world's nostalgia towards the East. Analyzing the aesthetic characteristics of Hanae Mori's clothes what kinds of aesthetic characteristic that her work had and what kinds of influences that she made in the modern fashion would provide substantial contribution of the world's modern fashion. This study provided forms and remarkable features of Japanese traditional custom, revealed Hanae Mori's life and her philosophies of fashion, and defined Hanae Mori's aesthetic characteristics by analyzing her work from 1970's until the retirement, July 2004. Methods of this study are completed by documentary records of Hanae Mori, research papers and fashion magazines that are published domestically and internationally, and collected materials from internet. The results of analysis are epitomized as below. Hanae Mori was the first Japanese fashion designer who expressed the characteristics of traditional Japanese custom with modernity sprit. In the 60's and 70's, especially in the U.S. and European fashion market, she inspired western fashion designers by her original sprit of art: combining Japanese tradition which showed distinctive color and spirit of nature and the western beauty. Hanae Mori created new dress molding from the Kimono's unstructured feature. Her layered look dressing, oblique adjustment and Obi, and others all enabled Mori to express Japanese image into modern fashion. Additionally, in terms of traditional Japanese image being acknowledged world-widely, she played a major contribution in world fashion by suggesting a new vision and raised several sensations in fashion artistry and modeling. Amongst her various patterns, Hanae Mori had butterfly patterns in most of her works, which was her representative symbol. This spoke for her strong will and senses of duty that wanting to inform beauty of Japanese women who were reflected in modern and graceful butterfly patterns. Flowers were another element that symbolized Mori. Using various flower motifs that bloomed in every different four seasons, she connected two images into her fashion; beauty of the nature and enlightening image of vibrating life. The aesthetic characteristics of Hanae Mori's clothes were defined as five: Japonism, naturalism, feminism, eroticism, and modernism. Japonism which is the spirit of Japanese, Mori used the concept to connect the East and the West. Naturalism represented harmony of the nature and the human. Feminism highlighted Eastern women's beauty. Eroticism emitted feminine attraction. Modernism represented simplicity and sophistication. Such aesthetic character illustrated Mori's original emotion that was based on Japanese spirit and she combined it with values of the East and the West. From the analysis of Mori's aesthetic characteristics, it is clearly recognizable her feministic beauty is emanated by her original emotion and sensibility.

The shoulder diagnosis Scapula study of patients who visited the hospital (병원 내원한 환자 견갑골(scapula) 진단을 위한 연구)

  • Ahn, Byeong-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 2010
  • True lateral scapula image was very important to diagnosis the scapula fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapula true lateral in korean. d Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine Anteroposterior projection taken with $30^{\circ}$, $40^{\circ}$, $45^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlap of vertebral border and axillary border of scapula as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor.$30^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $40^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $45^{\circ}$ trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. There was no result of trunk rotation angle to radiograph the true scapula lateral image up to date. This studies were summarized as follows; Adaptation of $40^{\circ}$ trunk rotation was the best to show the true scapula lateral image in korean. Our results were very useful to get the true scapula lateral images in clinic.