• Title/Summary/Keyword: Objective Lens

Search Result 223, Processing Time 0.024 seconds

A Hybrid Recommendation System based on Fuzzy C-Means Clustering and Supervised Learning

  • Duan, Li;Wang, Weiping;Han, Baijing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.7
    • /
    • pp.2399-2413
    • /
    • 2021
  • A recommendation system is an information filter tool, which uses the ratings and reviews of users to generate a personalized recommendation service for users. However, the cold-start problem of users and items is still a major research hotspot on service recommendations. To address this challenge, this paper proposes a high-efficient hybrid recommendation system based on Fuzzy C-Means (FCM) clustering and supervised learning models. The proposed recommendation method includes two aspects: on the one hand, FCM clustering technique has been applied to the item-based collaborative filtering framework to solve the cold start problem; on the other hand, the content information is integrated into the collaborative filtering. The algorithm constructs the user and item membership degree feature vector, and adopts the data representation form of the scoring matrix to the supervised learning algorithm, as well as by combining the subjective membership degree feature vector and the objective membership degree feature vector in a linear combination, the prediction accuracy is significantly improved on the public datasets with different sparsity. The efficiency of the proposed system is illustrated by conducting several experiments on MovieLens dataset.

Morpho-GAN: Unsupervised Learning of Data with High Morphology using Generative Adversarial Networks (Morpho-GAN: Generative Adversarial Networks를 사용하여 높은 형태론 데이터에 대한 비지도학습)

  • Abduazimov, Azamat;Jo, GeunSik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.01a
    • /
    • pp.11-14
    • /
    • 2020
  • The importance of data in the development of deep learning is very high. Data with high morphological features are usually utilized in the domains where careful lens calibrations are needed by a human to capture those data. Synthesis of high morphological data for that domain can be a great asset to improve the classification accuracy of systems in the field. Unsupervised learning can be employed for this task. Generating photo-realistic objects of interest has been massively studied after Generative Adversarial Network (GAN) was introduced. In this paper, we propose Morpho-GAN, a method that unifies several GAN techniques to generate quality data of high morphology. Our method introduces a new suitable training objective in the discriminator of GAN to synthesize images that follow the distribution of the original dataset. The results demonstrate that the proposed method can generate plausible data as good as other modern baseline models while taking a less complex during training.

  • PDF

Trends and Refractive Status of Cataract Surgery - An Optometry Clinic-Based Survey in Chungbuk (백내장 수술 경향과 굴절상태 - 충북 지역의 안경원 중심으로 조사)

  • Kim, Hyeong-Su;Son, Jeong-Sik;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the distribution of age and gender, types of intraocular lens (IOL), and refractive errors in subjects who had cataract surgery. Methods: 2,217 subjects who had cataract surgery were surveyed at an optometry clinic in Chungbuk from 2010 to 2012. Information about IOL was obtained from case history, reflective and retroillumination images IOL by auto refracto-keratometer. Refractive errors were determined by objective and subjective refraction. Results: The mean age of the subjects was $71.74{\pm}10.62$ years. The number of cataract surgeries increased from 524 persons in 2010 to 888 persons in 2012. Of the subjects surveyed, 52 persons (2.3%) were under the 40 years of age, 144 persons (6.5%) were in 50s, 404 persons (18.2%) were in 60s, 1,132 persons (51.1%) were in 70s, 485 persons (21.9%) were in above 80s. Cataract surgery was significantly prevalent in more female (1,338 persons, 60.4%) than in male (879 persons, 39.6%). Types of IOL were 2,141 persons (96.6%) for monofocal lens, special IOLs such as multifocal, accommodative and toric lens were 76 persons (3.4%). The distribution of refractive errors after cataract operation were 1,588 eyes (38.5%) for simple myopic astigmatism, 327 eyes (7.9%) for simple hyperopic astigmatism, 601 eyes (14.6%) for mixed astigmatism, 1,240 eyes (30.0%) for myopia, 136 eyes (3.3%) for hyperopia, and 234 eyes (5.7%) for emmetropia. The uncorrected and best corrected visual acuity of the subjects were $0.55{\pm}0.25$ and $0.80{\pm}0.23$, respectively. Conclusions: The prevalence of cataract surgery increased with age until 70s years of age, it was more prevalent in men than women over 60s, and frequency of special types of IOL were low. Most cataract surgeries left residual refractive errors. Therefore even after cataract surgery it may need spectacles for better vision at either distance or near.

A Comparative Analysis of increased along with the age presbyopic additions in city and island villages (도시와 섬마을 노안의 연령에 따른 근용 가입도의 비교 관찰)

  • Kim, In-Suk;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.61-65
    • /
    • 2002
  • This study examines how the average presbyopic additions and eye refraction state of old ages in city may be different to that island. There were 677 of the old who were 50 or over 90 in the sample. The visual acuity test was done by objective and subjective methods and used for near-chart program. The far-point refraction state and power of the additions lens results were as follows ; 1. Of far-point refraction state in city peoples; male: emmetropia 10%, myopia 17%, hyperopia 19%, mixed astigmatism 38%, etc. 16% female : emmetropia 20%, myopia 20%, hyperopia 20%, mixed astigmatism 27%, etc. 13% 2. Of far-point refraction state in island villages ; male : emmetropia 13%, myopia 17%, hyperopia 22%, mixed astigmatism 40%, etc. 8% female : emmetropia 7%, myopia 13%, hyperopia 26%, mixed astigmatism 44%, etc. 10% 3. Average presbyopic additions states has been presented no discrimination ; male: 50 to 60 : +1.25 or +1.50D, 61 to 65 : +1.75 or + 2.00D, 66 to 70 : +2.25 or +2.50D 71 to 75 : +2.75 or +3.00D, 76 to 80 : +3.25 or +3.50D, over81 : +3.75D female : 50 to 60 : +1.25 or + 1.50D, 61 to 65 : +1.75 or + 2.00D, 66 to 70 : +2.25 or +2.50D 71 to 75 : +2.25 or + 2.50D, 76 to 80 : +2.75 or +3.00D, over81 : +2.75 or +3.00D 4. Under the condition of wearing lens, the average working time was 1 or 2 hour but some people used over 5 hours. 5. Generally, it has been investigated the old ages peoples has ocular diseases and cataract was the most common.

  • PDF

Study on the Scan Field of Modified Octupole and Quadrupole Deflector in a Microcolumn (마이크로칼럼에서 변형된 4중극 디플렉터와 8중극 디플렉터의 스캔 영역 비교)

  • Kim, Young Chul;Kim, Ho-Seob;Ahn, Seong Joon;Oh, Tae-Sik;Kim, Dae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2018
  • In a microcolumn, a miniaturized electrostatic deflector is often adopted to scan an electron beam. Usually, a double octupole deflector is used because it can avoid excessive spherical aberrations by controlling the electron beam path close to the optical axis of the objective lens and has a wide scan field. Studies on microcolumns have been performed to improve the low throughput of an electron column through multiple column applications. On the other hand, as the number of microcolumns increases, the number of wires connected to the components of the microcolumn increases. This will result in practical problems during the process of connecting the wires to electronic controllers outside of the vacuum chamber. To reduce this problem, modified quadrupole and octupole deflectors were examined through simulation analysis by selecting an ultraminiaturized microcolumn with the Einzel lens eliminated. The modified deflectors were designed changing the size of each electrode of the conventional Si octupole deflector. The variations of the scan field and electric field strength were studied by changing the size of active electrodes to which the deflection voltage was to be applied. The scan field increased linearly with increasing deflection voltage. The scan field of the quadrupole deflector and the electric field strength at the center were calculated to be approximately 1.3 ~ 2.0 times larger than those of the octupole deflector depending on the electrode size.

Endoscopic Removal of Traumatic Intracerebral Hematoma via Superolateral Keyhole (외상성 뇌실질내 혈종에 대한 상측방 키홀을 통한 내시경적 혈종 제거)

  • Park, Sung-Jin;Ha, Ho-Gyun;Jung, Ho;Lee, Sang-Keol;Park, Moon-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.249-254
    • /
    • 2000
  • Objective : As a minimally invasive strategy, endoscopic technique was introduced for removal of the traumatic intracerebral hematoma. Material and Method : A 54-year-old man with three-day history of seizure and progressive mental deterioration after traffic accident was presented. Computerized Tomography(CT) of the brain showed a huge intracerebral hematoma on the right frontal lobe and ventricle. The operation was performed via right frontal superolateral keyhole with 2cm eyebrow skin incision. Using 0-degree and 30-degree angled lens 4mm rigid endoscopes, nearly all of the hematoma was evacuated under the direct endoscopic visualization and a ventricular catheter was exactly placed into the frontal horn of the right lateral ventricle at the end of procedure. Results : The seizure was discontinued and neurological status had been improved during postoperative periods. Postoperative CT demonstrated that most of the hematoma was removed and the ventricular drainge tube was exactly placed in the right foramen of Monro. Conclusion : With endoscopic technique, the authors successfully evacuated traumatic intracerebral hematoma and exactly placed the ventricular drainage catheter under direct visualization. This technique may be considered as an another option for removal of traumatic intracerebral hematoma.

  • PDF

Extraction of Subject Size in Still Image Using Floor Pattern (바닥 패턴을 이용한 단일영상 내의 피사체 크기 추출)

  • Hwang, Min-Gu;Kim, Dong-Min;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.11-17
    • /
    • 2011
  • This paper aims to realize the information of a subject existing in a still image with objective values. To attain the goal, this research takes the vanishing point that a 2D still image has as the basis and recomposes the still image into a 3D image using a 3D program. Also, in order to set up the axis of the camera necessary to recompose a 3D image, this paper used the lens angle of view that the image has and floor patterns as well. The 3D image completed in this way can measure the size and distance of all subjects in the floor patterns if the size value of a particular reference subject is known, and through this, it can be possible to acquire basic information of a subject that can be either a criminal or a clue in the images of CCTVs or some criminal scene.

Synchrotron Radiation Imaging of Tissues Using Phase Contrast Technique (방사광 위상차 현미경을 이용한 생체조직의 미세구조 영상)

  • Kang, Bo-Sun;Lee, Dong-Yeol;Kim, Ki-Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.23-30
    • /
    • 2008
  • X-ray microscopy with synchrotron radiation(SR) might be a useful tool for novel x-ray imaging in the clinical and laboratory settings. Microscopically, it enables us to observe detailed structure of animal organs samples with a great magnification power and an excellent resolution. The phase contrast mechanisms in image by X-ray are described. The phase-contrast X-ray imaging with SR from in-vivo and in-vitro mouse tail, rat nerve and rat lung were obtained with an 8 KeV monochromatic beam. The visual image was magnified using 10x microscope objective lens and captured using an digital CCD camera. The results showed more structural details and high resolution images with SR imaging system than conventional X-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications and clinical radiography.

  • PDF

Relationship between Uncorrected Visual Acuity and Refraction of the Children and Teenagers (소아, 청소년의 나안시력과 굴절이상의 상관성 분석)

  • Kim, Sang-Moon;Shim, Hyun-Seok;Shim, Jun-Beom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.173-178
    • /
    • 2013
  • Purpose: This study is to predict refractive errors according to uncorrected visual acuity using uncorrected visual acuity of the first glasses wearers. Methods: For 886 children who visited an ophthalmic clinic, subjective refraction was carried out with maintain refraction (MR) and cycloplegic refraction (CR), and objective refraction was carried out using auto-refractometer. Uncorrected visual acuity and corrected visual acuity were tested using on a trial lens and a Han's visual acuity chart. Results: In correlation between with the uncorrected visual acuity and refractive the myopia was the highest (r=0.774) and followed by hyperopia (r=0.670), simple astigmatism (r=0.623), simple with-the-rule astigmatism (r=0.604)and simple against-the-rule astigmatism (r=0.508). Conclusions: There were differences in the predictions between uncorrected visual acuity and refractive error according to the types of refractive error and astigmatism.

Diffraction Efficiency Analysis of Silver Halide Film for Color Holography Recording

  • Park, Sung Chul;Kim, Sang Il;Son, Kwang Chul;Kwon, Soon Chul;Lee, Seung Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.16-27
    • /
    • 2015
  • Holography technology which was developed by Dennis Gabor (1900~1979) in 1948 is a technology to record wave planes of actual 3D objects. It is known as the only technology which can express 3D information most perfectly close to human-friendly. Holography technology is widely used in advertisement, architecture and arts as well as science technology areas. Especially, digital holographic print which is an applied area is greatly used in military map, architecture map and cultural asset restoration by printing and reproducing 3D information. Holography is realized by recording and reproducing the amplitude and phase information on high resolution film using coherent light like laser. Recording materials for digital holographic printer are silver halide, photoresist and photopolymer. Because the materials have different diffraction efficiency according to film characteristics of each manufacturer, appropriate guide lines should be suggested through efficiency analysis of each film. This paper suggests appropriate guide lines through the diffraction efficiency measurement of silver halide which is a holographic printer recording medium. And the objective of this study is to suggest appropriate guide lines through diffraction efficiency analysis of Ultimate 08-C and PFG-03C which are commercially used. The experiment was prepared by self-diffraction efficiency system which measures the strength with the defector by penetrating RGB recording medium and concentrating diffracted beams through collimating lens. The experiment showed Geola's PFG-03C which is a silver halide for full color has price/performance advantage in optical hologram recording, but recording angles and reproduction angles are irregular for digital holographic printer recording. Ultimate's Ultimate08-C for full color shows its diffraction efficiency is relatively stable and high according to recording angles and laser wavelength.