• Title/Summary/Keyword: Objective Lens

Search Result 223, Processing Time 0.03 seconds

Analysis and Optimal Design of Optical Pickup Actuator by 3D-EMCN Method (3D-EMCN법을 이용한 광 픽업 액츄에이터의 해석 및 최적설계)

  • Kim, Jin-A;Jeon, Tae-Gyeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.234-241
    • /
    • 2002
  • An optical pickup actuator is an objective-lens-moving mechanism that provides a means to follow the disk displacement accurately(1). In this paper, a slim type optical pickup actuator for Notebook PCs is analyzed and designed to improve the driving sensitivity A three dimensional equivalent magnetic circuit network method (3D-EMCN method) is proposed for an analysis method which provides better characteristics in both precision and computation time of analysis comparing with a commercial three-dimensional finite element (3D-FEM) codes. To verify the validity of proposed method, we made a comparison between the analysis results and the experimental ones. We also compared this analysis results with 3D-FEM results. Among the several optimal algorithm, we adopt a niching genetic algorithm, which renders a set of the multiple optimal solutions. RCS (Restricted Competition Selection) niching genetic algorithm is used for optimal design of the actuator's performance. Recently, the pickup actuator needs additional driving structure for radial and tangential tilting motion to obtain better pick-up performance. So we applied the proposed method to the model containing tilting coils.

Development of Multi-Purpose Variable Polarization Imaging System for Clinical Diagnosis (임상 진단용 다목적 가변 편광 영상장치 개발)

  • Bae, Young-Woo;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.265-270
    • /
    • 2007
  • Polarization imaging systems have been widely used to selectively characterize skin lesions. Nevertheless, current systems are used in single-mode due to the limitations of a fixed polarization mode and a single-working distance of light source, in which uniform light distribution is achieved on target area. To address such limitations, we developed a variable polarization imaging system based on multi-working distance of light source for various clinical diagnoses. In this study, we characterize the imaging system and present experiment results demonstrating its clinical usefulness. The imaging system consists of a CCD color camera, linear polarization filters, and a single-layered LED ring light source which provides uniform light distribution at multi-working distances. The first polarizer was placed on the light source and the second polarizer placed on objective lens provides continuous linear polarization angle from $0^{\circ}\;to\;90^{\circ}$. The clinical efficacy of the imaging system was investigated by acquiring and analyzing clinical images of skin wrinkle and dental plaque. With the experiments, we verified the potential usefulness of the imaging system for other clinical applications.

3-axis Moving Magnet Type Actuator (가동 자석형 3 축 구동 엑츄에이터)

  • Hur, Young-Jun;Song, Myeong-Gyu;Park, No-Cheol;Yoo, Jeong-Hoon;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1033-1036
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to equip 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added tilting mechanism to 2-axis moving magnet actuator which is designed in previous research. Addition of the tilting mechanism cuts down the focusing sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF

Measurement of Micro Thermal Deformation of Optical Pick-up Base Using Holographic Interferometry (흘로그램 간섭계를 이용한 광픽업 베이스의 미소 열변형 측정)

  • 서영민;강신일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.191-194
    • /
    • 2002
  • In optical pick-up, optical components such as objective lens, collimator, mirror, laser diode and photo diode are mounted on the pick-up base. These components must keep their original position during operation for proper transmittance of information from laser diode to optical disk and back to photo diode. However, micro thermal deformation of pick-up base which is induced by thermal environment during operation can deteriorate the performance of optical pick-up. Therefore, it is important to measure and analyze the thermal deformation behavior of pick-up base under thermal environment. In the present study, a measurement system using holographic interferometry was designed to measure micro thermal deformation of pick up base. The measurement system was verified by using the deformation of cantilever with prescribed motion actuated by PZT with 1 nm resolution. Interferometric measurement was compared quantitatively with that induced by PZT actuator. Finally, micro thermal deformation of pick-up base under actual thermal environment was measured using the present holographic interferometry and the results were analysed.

  • PDF

Investigation into direct fabrication of nano-patterns using nano-stereolithography (NSL) process (나노 스테레오리소그래피 공정을 이용한 무(無)마스크 나노 패턴제작에 관한 연구)

  • Park Sang Hu;Lim Tae-Woo;Yang Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.156-162
    • /
    • 2006
  • Direct fabrication of nano patterns has been studied employing a nano-stereolithography (NSL) process. The needs of nano patterning techniques have been intensively increased for diverse applications for nano/micro-devices; micro-fluidic channels, micro-molds. and other novel micro-objects. For fabrication of high-aspect-ratio (HAR) patterns, a thick spin coating of SU-8 process is generally used in the conventional photolithography, however, additional processes such as pre- and post-baking processes and expansive precise photomasks are inevitably required. In this work, direct fabrication of HAR patterns with a high spatial resolution is tried employing two-photon polymerization in the NSL process. The precision and aspect ratio of patterns can be controlled using process parameters of laser power, exposure time, and numerical aperture of objective lens. It is also feasible to control the aspect ratio of patterns by truncation amounts of patterns, and a layer-by-layer piling up technique is attempted to achieve HAR patterns. Through the fabrication of several patterns using the NSL process, the possibility of effective patterning technique fer various N/MEMS applications has been demonstrated.

A study on the optimal control of Long Stroke Fast Tool Servo Systems (장거리 구동용 FTS 의 최적 제어에 관한 연구)

  • 이상호;이찬홍;김갑순
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.818-821
    • /
    • 2004
  • With a rapid development in the area of micro and ultra precision technology, the micro surface machining of small size parts are explosively increased. Especially, to improve efficiency of various beams in lens and reflector, non-rotational symmetric form and several mm level heights changeable surface can be machined at a time. These geometric complex 3D surface cannot be machined by general short stroke FTS. The long stroke FTS if firmly needed to move directly several mm and have nm level positioning accuracy for the complex surface form. The long stroke FTS used linear motors to drive moving unit long and fine, aero static bearings to decrease friction and moving errors in guide way, optical linear scale with nm level resolution to measure position of FTS. Furthermore, to increase the performance of acceleration of FTS, the light material, such as AL is used for the structure and the high stiffness box type structure is selected. In this paper, the genetic algorithm approach is described to determine a set of design parameters for auto tuning. The authors have attempted to model the design problem with the objective of minimizing the error, such as variable pattern change. This method can give the better alternative than existing other method.

  • PDF

Study on Dual-Lenses Actuator for HD-DVD System (차세대 DVD 시스템용 Actuator 연구)

  • Kim, Seok-Jung;Lee, Yong-Hoon;Ahn, Young-Man;Chung, Chong-Sam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.777-781
    • /
    • 2002
  • Recently, an optical disc system has been proposed using blue laser diode, high NA objective lens and groove only disc structure. A new method is needed to readout CD and DVD in this blue system. In order to readout CD and DVD in HD-DVD system, we adopted dual-lenses actuator in consideration of optical utilization efficiency, optical performance and insurance of sufficient W.D (working distance). This dual-lenses actuator has two objectives in radial direction, one is for CD/DVD and the other is for HD-DVD. We had to solve the induced problems of DC tilt increase, $2^{nd}$ resonance deterioration and AC sensitivity drop caused by disposing two lenses in an actuator. Especially, to solve AC sensitivity drop, we introduced two 2-pole magnets and separated focus and track magnetic circuits. Consequently we presented that dual-lenses actuator has been possessed good performance. And we measured eye patterns of CD, DVD and HD-DVD by using HD-DVD optical pick-up with dual-lenses actuator.

  • PDF

Characteristics of Hybrid Optical Pickup Actuator at High Temperature (하이브리드형 광픽업 액추에이터의 고온특성)

  • Lee, Jin-Won;Kim, Kwang;Cheong, Young-Min;Kim, Dae-Whan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.1010-1014
    • /
    • 2002
  • A new type actuator has been designed and investigated to overcome thermal problems in slim optical disc drive which is adopted in mobile storage devices. Recently, in optical storage device technical trends, the size of optical disc drives is slimmer to adopt notebook computer and the spindle rotate velocity is faster to achieve high transfer rate and the power of actuator is higher to perform tilting, etc. However, these trends of optical disc drives tend to raise the environment temperature of drives, actuator power and parts temperature. Moreover, it is more difficult to remove the heat inside a drive and the temperature of an actuator increases and drive slims. As a result, increase of surface temperature of actuator body caused that second resonance of an actuator moves down to a lower frequency band and the performance of optical parts also deteriorates. Especially objective lens, coil and magnet of the actuator parts are easily damaged. To manage these thermal problems, in this paper an actuator with a hybrid blade, which is composed of vectra which has low thermal conductivity and magnesium which has high thermal conductivity, has been suggested and verified. Despite the high temperature environment, the proposed actuator showed good dynamic performance.

  • PDF

Analysis and Reduction of Subsidiary Resonance of an Optical Pickup Actuator (광 픽업 액추에이터의 부공진 원인 규명과 저감화)

  • Seo, Jin-Gyu;Jeong, Ho-Seop;Park, Gi-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.728-734
    • /
    • 2000
  • An asymmetric actuator can be used to reduce the distance between the reflective mirror and objective lens of a small optical disk drive for use in the notebook-sized personal computer data storage devices. However, this asymmetric actuator is very sensitive to the subsidiary resonance which is caused by its rigid body motion. In this paper, an analytical approach using a simple lumped parameter system model is presented with a physical insight to investigate why the subsidiary resonance occurs. The finite element method is used to figure out the force and torque characteristics of the asymmetric actuator which are essential to understand the subsidiary vibration characteristics. The frequency responses are presented to examine how the subsidiary resonance is altered for various situations of having different thickness of a yoke and permanent magnet and of having a different magnet circuit. Finally, the design guidelines to avoid the subsidiary resonance will be presented.

Theoretical Calculation on Radiation Patterns of Epi-signal in CARS Microscopy (간섭성 반스톡스 라만 산란 현미경 후방 신호지 방사패턴에 관한 이론계산 연구)

  • Yoo, Yong-Shim;Cho, Hyuck
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.286-291
    • /
    • 2007
  • We theoretically investigated the far-field radiation pattern of epi-signal from a polystyrene sphere in coherent anti-Stokes Raman scattering (CARS) microscopy with an objective lens of high numerical aperture. We calculated the field distribution of the incident laser beams under the tight-focusing condition and the far-field radiation pattern through coherent addition of radiation from the nonlinear polarizations (Hertzian dipoles) as the origin of CARS signal generation. The epi-radiation patterns for polystyrene spheres of different diameters are calculated, and the pattern of a sphere is also compared with that of a shell fer a diameter of 1100 nm. We finally show how the radiation pattern of the polystyrene sphere changes as the center of the sphere shifts from the focus of the beam.