• Title/Summary/Keyword: ORB

Search Result 164, Processing Time 0.023 seconds

KIC 6206751: the first R CMa-type eclipsing binary with ɣ Doradus pulsations

  • Lee, Jae Woo;Park, Jang-Ho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.84.2-84.2
    • /
    • 2019
  • We present the absolute properties of the double-lined eclipsing binary KIC 6206751 exhibiting multiperiodic pulsations. The Kepler light curve of this system was simultaneously solved with the previously published radial-velocity data. The results indicate that the binary star is a short-period semi-detached system with fundamental parameters of $M_1=1.66{\pm}0.04M_{\odot}$, $M_2=0.215{\pm}0.006M_{\odot}$, $R_1=1.53{\pm}0.02R_{\odot}$, $R_2=1.33{\pm}0.02R_{\odot}$, $L_1=5.0{\pm}0.6L_{\odot}$, and $L_2=0.96{\pm}0.09L_{\odot}$. We applied multiple frequency analyses to the eclipse-subtracted light residuals and detected the 42 frequencies below $2.5days^{-1}$. Among these, three independent frequencies of $f_2$, $f_3$, and $f_4$ can be identified as high-order ($38{\leq}n{\leq}40$) low-degree (l=2) gravity-mode oscillations, whereas the other frequencies may be orbital harmonics and combination terms. The ratios between the orbital frequency and the pulsation frequencies are $f_{orb}:f_{2-4}{\simeq}2:3$, which implies that the ${\gamma}$ Dor pulsations of the detached primary star may be excited by the tidal interaction of the secondary companion. The short orbital period, and the low mass ratio and $M_2$ demonstrate that KIC 6206751 is an R CMa-type star, which is most likely evolving into an EL CVn star. Of seven well-studied R CMa-type stars, our program target is the only eclipsing binary with a ${\gamma}$ Dor pulsating component.

  • PDF

Absolute Dimension and Pulsational Characteristics of the Eclipsing Binary EW Boo with a δ Sct Pulsator

  • Kim, Hye-Young;Hong, Kyeongsoo;Kim, Chun-Hwey;Lee, Jae Woo;Jeong, Min-Ji;Park, Jang-Ho;Song, Mi-Hwa
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.34.4-35
    • /
    • 2021
  • We present the TESS photometry and our high-resolution spectra of the semi-detached Algol EW Boo. For an orbital period study, we collected all available times of minima including ours for the last 30 years. It is found that the eclipse timing variation of the system can be represented by a periodic oscillation of 18.5±1.0 yr plus a secular period increase with a rate of [dP/dt]orb=-6(±3)×10-8 d yr-1. From our observed spectra, the effective temperature of the primary star was determined to be Teff,1=8560±118 K. From a simultaneous analysis of the TESS light and our double-lined radial velocity curves, the absolute masses, radii, and luminosities are M1=2.30±0.07M, M2=0.38±0.01M, R1=1.92±0.02 R, R2=1.27±0.01 R, L1=1.92±0.02 L, and L2=0.752±0.007 L, respectively. Multiple frequency analyses were carried out for the light residuals after subtracting the binary star model. We detected a total of 75 frequencies in the region of 16.50-104.8 day-1. Our results demonstrate that the more hotter primary star of EW Boo is a δ Sct pulsator by considering its position in the δ Scuti region of the Cepheid instability strip and pulsational characteristics.

  • PDF

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

A Construction of TMO Object Group Model for Distributed Real-Time Services (분산 실시간 서비스를 위한 TMO 객체그룹 모델의 구축)

  • 신창선;김명희;주수종
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.5_6
    • /
    • pp.307-318
    • /
    • 2003
  • In this paper, we design and construct a TMO object group that provides the guaranteed real-time services in the distributed object computing environments, and verify execution power of its model for the correct distributed real-time services. The TMO object group we suggested is based on TINA's object group concept. This model consists of TMO objects having real-time properties and some components that support the object management service and the real-time scheduling service in the TMO object group. Also TMO objects can be duplicated or non-duplicated on distributed systems. Our model can execute the guaranteed distributed real-time service on COTS middlewares without restricting the specially ORB or the of operating system. For achieving goals of our model. we defined the concepts of the TMO object and the structure of the TMO object group. Also we designed and implemented the functions and interactions of components in the object group. The TMO object group includes the Dynamic Binder object and the Scheduler object for supporting the object management service and the real-time scheduling service, respectively The Dynamic Binder object supports the dynamic binding service that selects the appropriate one out of the duplicated TMO objects for the clients'request. And the Scheduler object supports the real-time scheduling service that determines the priority of tasks executed by an arbitrary TMO object for the clients'service requests. And then, in order to verify the executions of our model, we implemented the Dynamic Binder object and the Scheduler object adopting the binding priority algorithm for the dynamic binding service and the EDF algorithm for the real-time scheduling service from extending the existing known algorithms. Finally, from the numerical analyzed results we are shown, we verified whether our TMO object group model could support dynamic binding service for duplicated or non-duplicated TMO objects, also real-time scheduling service for an arbitrary TMO object requested from clients.