• Title/Summary/Keyword: OPEN WATER

Search Result 1,861, Processing Time 0.031 seconds

Oceanographic Characteristics of the Japan Sea Proper Water I. Oceanographic Conditions of the Japan Sea and the Japan Sea Proper Water in Winter (동해고유수의 해양학적 특성 I. 겨울철 동해의 해황과 동해고유수)

  • 최용규;양성기
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.317-332
    • /
    • 1994
  • Based on the Results of Marine Meteorological and Oceanographical Observations (1966 ~ 1987), oceanographic conditions of the Japan Sea in winter was studied in relation to the Japan Sea Proper Water (JSPW). The mean and dispersion of the deep water above 1000 m depth are 0.26$\pm$0.2$^{\circ}C$ in temperature and 5.1$\pm$0.25 ml/h in oxygen. The mean and dispersion of the bottom water below 1000m depth are 0.07$\pm$$0.04^{\circ}C$ in temperature and 5.1$\pm$0.15ml/1 in oxygen. The distributions of the temperature and dissolved oxygen in the deep water above 1000m depth are ranged wider than 각one of the bottom water below 1000m depth in T-S and T-$ extrm{O}_2$ diagrams. The bottom water are showed more homogeneous and smaller variations than the deep water in the characteristics of water mass. The deep water above 1000m depth is active in contact with the atmosphere. The JSPW similar to the above characteristics is showed in the open ocean of the north of $40^{\circ}$30""N, west of $138^{\circ}$E. Therefore, the deep water is formed probably by the open-ocean convection.tion.

  • PDF

Performance Evaluation of Open-Loop Ground Water Heat Pump system (개방형 지열히트펌프 시스템의 성능평가)

  • Kim, Tae-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.9-14
    • /
    • 2006
  • Open loop or ground water heat pump systems are the oldest of ground-source systems. Standing column wells can be used as highly efficient ground heat exchanger in geo-thermal heat pump systems, where hydrological and geological conditions are suitable. These systems require some careful considerations for well design, ground water flow, heat exchanger selection etc This paper describes 9round water temperature variations, performances in heat ins and cool ing mode and the results of ground water analysis.

  • PDF

Development of Open Water Management Program(OWMP) for Water Management Automation System with Open Architecture (물관리자동화시스템을 위한 개방형 운영 프로그램 개발)

  • Kim, Sun-Joo;Kim, Pill-Sik;Yoon, Chan-Young
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.84-88
    • /
    • 2001
  • This study presents an application of object-oriented methodology for Open Water Management Program(OWMP). Accordingly, OWMP provides a high degree of reliability which allows modification of parameters by change of region or time to be possible OWMP consists of Data Base Management System(DBMS) and Model System. DBMS make it possible to analyze data related with planning water schedule and establishing database. Model System calculates reservoir inflow, reservoir effluent and basin water demand. A operator decides the reservoir operation with results of Model System and DBMS. OWMP could be adapted to the planning and decision for saving water.

  • PDF

Study of the Open-Water Test and Analysis for a Pumpjet Propulsor in LCT (대형 캐비테이션터널에서 펌프젯 추진기 단독성능 시험 및 해석 기법 연구)

  • Ahn, Jong-Woo;Seol, Han-Shin;Jung, Hong-Seok;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.3
    • /
    • pp.149-156
    • /
    • 2022
  • In order to study the open-water test and analysis techniques for pumpjet propulsors in the Large Cavitation Tunnel (LCT), at the Korea Research Institute of Ships and Ocean Engineering, a set of test equipment was designed and manufactured. The pumpjet propulsor is composed of rotor, stator and duct resulting in the strong interaction between the components. A ring-shaped sensor was developed to measure the thrust and torque for duct and stator. The test equipment including the pumpjet is installed on an existing POW dynamometer in the reverse direction. The results from the reverse POW test setup were validated against those from the conventional POW test setup in the Towing Tank (TT) as well as in the LCT. The pumpjet open-water test was conducted at the Reynolds number of around 1.0×106, at which the obtained experimental data became stable in the Reynolds number effect test. The open-water test for the rotor (rotor-only) was conducted to study whether the duct and stator should be considered as a part of the hull or the propulsor. On the basis of the test results, it was shown that the duct and stator could be included in the propulsor. The total thrust, combined thrust of rotor, duct, and stator was used for the pumpjet open-water test analysis. As the whole pumpjet is defined as a propulsor, it is thought that the self-propulsion test and analysis could be conducted in the same way as that of the conventional propeller.

Management of an Open Comminuted Fracture of the Metacarpus using Circular External Skeletal Fixation in a Korean Water Deer (Hydropotes inermis argyopus) (고라니에서 발생한 손허리뼈 개방 복합골절의 원형 외부골격고정법 적용)

  • Heo, Su-Young;Jeong, Seongmok;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.359-362
    • /
    • 2015
  • A Korean water deer was rescued after being hit by a motor vehicle. Clinical and radiographic examination revealed a grade III open fracture of the right metacarpus with severe soft tissue injury. The water deer underwent closed reduction of the fracture, which was stabilized by the application of the Ilizarov method of 4-ring circular external skeletal fixation (CESF) as a minimally invasive technique. The water deer was successfully released into the wild. CESF was advantageous for the stabilization of open comminuted fracture and the management of a severely contaminated wound in a Korean water deer. CESF can be used successfully in wild deer with good tolerance and minimal complications.

Design of Auto Feed Supply System for Fish Farm (양식장용 자동 먹이공급시스템 설계)

  • Oh, Jin-Seok;Jo, Kwan-Jun
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.709-713
    • /
    • 2009
  • Water pollution of coast has a significant impact on the fish farm and fisheries. For solving the water pollution problems the fish farms are moving to the open sea. The fish farms in open sea have to operate by the automatic feeding system and remote monitoring system for safety and management. This paper describes an automatic feeding system for fish farms in open sea. Water temperature and fish weight will change depending on the amount of feed. And the fish farm temperature is changed extremely in open sea than on land side. This paper described that the feed amount is calculated automatically according to temperature, fish weight, and the automatic feed system. And the performance of automatic feed system is verified with test model for operation test.

Behaviour Analysis of Irrigation Reservoir Using Open Water Management Program (개방형 물관리 프로그램을 이용한 관개용 저수지의 거동 분석)

  • Kim, Sun-Joo;Kim, Phil-Shik;Lim, Chang-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.1
    • /
    • pp.3-13
    • /
    • 2004
  • For optimal irrigation reservoir operation during flood and normal period, a general and systematic policy is suggested to make balance of the conflicting purposes between water conservation and flood control. We developed Open Water Management Program (OWMP) with an open architecture to deal with newly arising upgrade problems for optimal management of irrigation reservoir. And we evaluated the applicability of OWMP to estimate daily runoff from an agricultural watershed including irrigation reservoirs, and analyzed behaviour of irrigation reservoirs as irrigation water requirements considering frequency analysis of reservoir storage and frequency analysis water requirements for effective management of reservoir. When we executed OWMP with data produced from an experimental field, IHP basins, the mean relative errors of application of daily runoff and irrigation water requirement were less than 5%. We also applied OWMP to a Seongju irrigation reservoir to simulate daily runoff, storage and water requirement from 1998 to 2002, and the mean model efficiency between measured and simulated value was 0.76. Our results based on the magnitude of relative errors and model efficiency of the model simulation indicate that the OWMP can be a tool nicely adapted to the effective water management of irrigation reservoir for beneficial water use and flood disaster management.

Examining the Equality of Multi-Outlet Flow Rates within a Dual Open Channel (이중 수로 구조의 분배수로 내 다지점 유출 유량의 균등성 평가에 관한 연구)

  • Kim, Seong-Su;Park, No-Suk;Jeong, Woo-Chang;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.423-430
    • /
    • 2012
  • This study was conducted to qualify the equality of the flow distribution from open channel between rapid mixing basin and flocculation basins in a domestic S_ water treatment plant, and to suggest a remedy for improving the equality. In order to evaluate the feasibility of the suggested remedy, computational fluid dynamics (CFD) technique are used, and for verifying the CFD simulation results tracer tests were carried out. From the results of CFD simulation and tracer tests, it was investigated that the modification of hydraulic structure in the distribution channel, which is to install the longitudinal orifice baffle in flow direction, could improve the equality of the flow distribution over 75%.

Long-term Water Balance Analysis of Irrigation Reservoir using Open Water Management Program (개방형물관리 프로그램을 이용한 관개용 저수지의 장기물수지 분석)

  • Kim, Sun-Joo;Kim, Phil-Shik
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.235-238
    • /
    • 2003
  • In this study, we developed Open Water Management Program (OWMP) with an open architecture to deal with newly arising upgrade problems for a water management automation system. When we executed OWMP with data produced from an experimental field in Korea, the relative errors of this simulation were less than 5%. We developed runoff calculation model and verified it with measured data of 4 basins included in IHP. The relative errors came out less than 5% in all basins, except for one basin. We also applied OWMP to seongju irrigation reservoir to simulate daily runoff from 1998 to 2002, and the day, month, and year relative error between measured and simulated value was 0.25-0.05. Therefore the OWMP can be a tool nicely adapted to the optimal water management of irrigation reservoir.

  • PDF

Anxiolytic Effects of Total Saponin Fraction from Ginseng Radix Rubra on the Elevated Plus-Maze Model in Mice

  • Cha, Hwa-Young;Seo, Jeong-Ju;Park, Jeong-Hill;Choi, Kang-Ju;Hong, Jin-Tae;Oh, Ki-Wan
    • Journal of Ginseng Research
    • /
    • v.28 no.3
    • /
    • pp.132-135
    • /
    • 2004
  • This study was performed to investigate the anxiolytic effects of total sponin fraction from Ginseng Radix Rubra (KRG) in mice using the elevated plus-maze model. The water extract of KRG and ginseng total saponins (GTS) purified from the water extract of KRG were administered orally to mice. One hour after administration of KRG water extract and GTS, mice were tested on the elevated plus-maze. The water extract of KRG 100 mg/kg, and GTS 25 and 50 mg/kg did not increase open arm entries and time spent on open arm. However, GTS 100 mg/kg increased the number of open arm entries and time spent on open arm. On the other hand, as the plus-maze test was affected by changes in locomotor activity, an additional test was carried out with the specific aim of monitoring locomotor activity. The water extract of KRG 100 mg/kg, and GTS 25 and 50 mg/kg did not affect the locomotor activity. However, GTS 100 mg/kg significantly decreased locomotor activity. From this study, we suggest that GTS may play an imponant role on the anxiolytic effects in the plus-maze model.