유출지하수 열원 지열히트펌프시스템의 냉방성능 (Cooling Performance of Ground source Heat Pump using Effluent Ground Water)

  • 박근우;남현규;강병찬
    • 신재생에너지
    • /
    • 제3권4호
    • /
    • pp.47-53
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effluent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000ton/day$. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

유출지하수 열원 지열히트펌프시스템의 냉방성능 (Cooling Performance of Ground source Heat Pump using Effluent Ground Water)

  • 박근우;남현규;강병찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.471-476
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and c lose type heat pump system using effluent ground water was installed and tested for it church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000$ ton/day. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

유출지하수 열원 지열히트펌프시스템의 난방성능 (Heating Performance of Ground source Heat Pump using Effluent Ground Water)

  • 박근우;이응열
    • 신재생에너지
    • /
    • 제3권2호
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

물관리자동화시스템의 발전방향 (A New Directionin the Advance of TM/TC System)

  • 고광돈;여운식
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.99-104
    • /
    • 1999
  • In 2000 FFIA , FIA, RDC are united into new corporation. This corporation will manage rural water with TM/TC(Tele-Monitoring/Tele-Control) system. Most systems which were adopted in TM/TC system were Closed Control System which use exclusive network and protocol . Closed Control System can not support new corporation's requirement in water management system. Therefore, new corporation should adopt Open Control System as standard rural water management system. Open Control System support Fieldbus technology, TCP/IP various protocols, programming model, OPC which is essential to the water management program, and so on.

  • PDF

一定幅 急傾斜 開水路上을 流動하는 물의 깊이 變化에 관한 實驗的 硏究 (An Experimental Study on the Depth Variation of Water Flow on Steep Open Channel with Constant Width)

  • 박이동
    • 대한기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.86-95
    • /
    • 1986
  • 본 연구에서는 폭이 일정한 급경사 개수노상(0.15mW*1.6mL)을 상온의 물이 유동할 때 유동율과 수로 급경사에 따른 명입치에서의 유동깊이 변화를 실측을 통하여 밝히고 이념치와 비교하였다.

하천수를 정화하는 갈대습지의 개수부에 의한 질소제거 비교 (Comparison of Nitrogen Removal in Reed Wetlands with and Without Open Water Purifying Effluent from a Treatment Pond)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제8권1호
    • /
    • pp.37-44
    • /
    • 2005
  • Nitrate($NO_3-N$) and total nitrogen(TN) removal by a reed wetland with open water(Wetland 1) was compared with that of a reed wetland without open water(Wetland 2) from March to October 2002. The two wetlands were 25mL by 6mW. An open water area, 3mL by 6mW was designed at the middle of Wetland 1. Reeds(Phragmites australis) were transplanted into the wetlands in June 2000. Water of Sinyang Stream flowing into the Kohung Estuarine Lake located in the southern part of Korea was pumped into a primary treatment pond, whose effluent was discharged into the secondary pond. Effluent from the secondary pond was funneled into the wetlands. Inflow into the wetlands averaged about 20.0$m^3$/day and their hydraulic retention time was approximately 1.5 days. Average $NO_3-N$ removal by Wetland 1 was 117.61mg/$m^2{\cdot}day$ and that by Wetland 2 was 106.39mg/$m^2{\cdot}day$. $NO_3-N$ removal efficiency of Wetland 1 and 2 was 37% and 34%, respectively. TN removal by Wetlands 1 and 2 averaged 226.80 and 214.54mg/$m^2{\cdot}day$, respectively. TN abatement efficiency of Wetland 1 was 43% and that of Wetland 2 was 40%. $NO_3-N$ removal efficiency of Wetland 1 was significantly higher(p=0.038) than Wetland 2. TN removal efficiency of Wetland 1 was also significantly higher(p=0.044) than Wetland 2. The wetland with open water was more efficient for removal of $NO_3-N$ and TN than one without.

CFD MODELING VEGETATED CHANNEL FLOWS: A STATE-OF-THE-ART REVIEW

  • Choi Sung-Uk;Yang Won-Jun
    • Water Engineering Research
    • /
    • 제6권3호
    • /
    • pp.101-112
    • /
    • 2005
  • This paper presents the state of the art of the CFD applications to vegetated open-channel flows. First, important aspects of the physics of vegetated flows found through the laboratory experiments are briefly reviewed. Then, previous CFD applications to one-dimensional vertical structure, partly-vegetated flows, compound open-channel flows with floodplain vegetation, and fully three-dimensional numerical simulations are reviewed. Finally, topics for further researches such as relationship between the resistance and flexural rigidity, additional drag due to foliages, and melting the experience of CFD with the depth-averaged modeling, are suggested.

  • PDF

MAU프로펠러 단독특성의 수식표현 (Polynomial Representation for MAU-Propeller Open Water Characteristics)

  • 서정천;이창섭
    • 한국기계연구소 소보
    • /
    • 통권11호
    • /
    • pp.95-101
    • /
    • 1984
  • The MAU-series propellers were designed and tested in japan. This report presents the polynomial coefficients of open water Characteristics for each standard MAU-series propellers, obtained by multiple polynomial regression analysis in terms of pitch-diameter ratio and advance coefficient. The limitation of applicability and the accuracy of the regression polynomial are also discussed.

  • PDF

기액 이상류시의 원심펌프특성에 관한 실험적 연구 (An Experimental Study on the Centrifugal Pump Characteristics in Air-Water Two-Phase Flow)

  • 김성윤;이상일;김유택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.685-692
    • /
    • 2006
  • In a general centrifugal pump, if it is operated in a two-phase flow the activity of the impeller usually degrades and occasionally losses its function. However, the effect of break down of centrifugal pump due to entrained air has not been clarified yet. This paper shows the air-water two-phase flow characteristics of closed type and semi-open type impellers. In a sing1e-phase flow, closed-type impeller has higher efficiency and head. But in air-water two-phase flow semi-open type impeller's rates of decreases of efficiency and head are decreased.

만에 적용되는 천수방정식의 개방경계조건

  • 윤태훈;서승원
    • 물과 미래
    • /
    • 제20권3호
    • /
    • pp.219-228
    • /
    • 1987
  • 만내 및 입구부에 대한 흐름해석으로 천수방정식이 이용되었으며, 개방경계의 위치를 변화시키며 해석하였다. 만입구로부터의 거리를 변화시키며 설정된 반도형태의 개방경계에 대한 수치해석결과 적절한 개방경계의 위치는 만입구의 폭을 2B라 했을 때 이에 대한 관계로 표현할 수 있고 3B 이상인 경우에서 해는 안정한 상태로 되어 최적의 개방경계위치는 3B가 적절할 것으로 판단되었다. 천수방정식에 대한 수치기법으로는 전형적인 Galerkin 방법에 의한 유한요소법이 적용되었다.

  • PDF