• Title/Summary/Keyword: ON-OFF Control System

Search Result 1,188, Processing Time 0.029 seconds

A Study on Position Control of an Electro-Hydraulic Servo System Using High Speed On-Off Valves (고속전자밸브를 사용한 전기유압서보시스템의 위치제어에 관한 연구)

  • 허준영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.369-378
    • /
    • 1999
  • This paper presents position control of an electro-hydraulic servo system whoch is operated by four 2-2way high speed on-off valves with either PWM PID control method or sliding mode control method, The advantages of using high speed on-off valves instead of electo-hydraulic servo valves or electro-hydraulic proportional valves are low price robustness for oil contamination and direct control without a D/A converter. The system consists of load cylinder inertia car potentiometer and external load cylinder. The experiments were carried out under several conditions and the results were compared. As a result the sliding mode method has shown good control performance and the robust and stable positioning of the elector-hydraulic servo system can be achieved accurately.

  • PDF

Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve (고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF

Design of Remote Dimming Control System using Power Line Communication (전력선 통신을 이용한 원격 디밍 제어 시스템 설계)

  • Lee, Seung-Dae
    • Journal of the Korea Computer Industry Society
    • /
    • v.10 no.3
    • /
    • pp.99-104
    • /
    • 2009
  • In this paper, fluorescent lamp on/off control and luminous intensity used an power line communication and remotely will be able to control system design. Embodied the respectively illumination equipment and tools by the network using PLC. In order to remote control and on/off of illumination equipment, luminous intensity composed a server. Will convert a previous analog system with digital system and the possibility witch will reduce an error ratio was. Consequently will be able to simplify a circuit.

  • PDF

An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer (컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구)

  • Cho, Jin Ho;Lee, Dae Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

Electronic-Hydraulic Hitch Control System for Agricultural Tractor -Position Control- (트랙터의 전자유압식(電子油壓式) 히치제어 시스템에 관한 연구(硏究)(I) -위치제어(位置制御)-)

  • Yoo, S.N.;Ryu, K.H.;Park, J.G.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.3
    • /
    • pp.168-180
    • /
    • 1989
  • This study was attempted to develop the electronic-hydraulic hitch control system for position control of tractor plow and investigate the control performance of the system through experiments. Experiments were carried out to investigate the responses of the system to the step and sinusoidal inputs in position control. The effects of control mode, hydraulic flow rate, reference deadband, and proportional constant on control performance of the system were investigated. The following conclusions were derived from the study; 1. For the position control system operated on on-off control mode, positions of implement were controlled within ${\pm}0.73^{\circ}{\sim}{\pm}1.46^{\circ}$ in rockshaft angle to the reference position when the hydraulic flow rates were 5~15 l/min. For the position control system operated on PWM control mode, positions of implement were controlled within ${\pm}0.73^{\circ}$ to the reference position regardless of hydraulic flow rates. It means that the implement could be positioned more accurately to the reference position on PWM control mode than on on-off control mode. 2. As results of the frequency responses of the position control systems, no clear difference in control performance between on-off control and PWM control modes was found. As the hydraulic flow rates increased, the corner frequencies of amplitude attenuation and phase-angle change increased. It means that the control performance of the system could be improved as the hydraulic flow rate increases.

  • PDF

Servo Motor Control by On-Off Controller with Hysterisis (히스테리시스를 갖는 온-오프 제어기에 의한 서보모터의 제어)

  • 김영복;김성환;양주호;정병건
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.85-95
    • /
    • 1991
  • All physical systems are nonlinear to some degree. The examples are relay, backlash, deadzone, saturation element and so on. In the linear control system design, it is useful method to restrict the nonlinearity to the linearity of system over the operation range. It is worth noting that nonlinearities may be intentionally introduced in to a system. A simple of an intentional non-linearity is the Bang-Bang controller which uses the On-Off relay. In this paper, an angular position servosystem made of a DC servomotor controlled by a microcomputer is discribed. Authors use two methods in the design of controller. The one is linear controller designed by the optimal feedback control theory only and the other is nonlinear controller designed by On-Off relay with optimal feedback control theory. To do the real time control, the controller is designed by using 16bit personal computer and A/D.D/A converter(12bit) is used in order to convert the signal. According to this way, the results from real time control are as follows. 2) Under the On-Off controller with hysterisis the influence of disturbance is considerably smaller than the linerar controller. 3) An increase in the sampling period has a destabilizing effect. 4)In the controller performance, the response time of the On-Off controller is longer than that of the linear controller. To close, we note that the On-Off controller with hysterisis is more attractive than the linear controller in the presence of the input limit.

  • PDF

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

A Study Stability Analysis of a PWM Controlled Hydraulic Equipment (PWM 제어되는 유압장치의 안정성 해석)

  • ;Wennmacher, G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1469-1478
    • /
    • 1995
  • PWM control is a kind of nonlinear control. The merits of PWM control of hydraulic equipment are the robustness of the high speed on-off valve and its low price. And it is easily implemented to hydraulic equipments with microcomputer. The high speed on-off valve is directly digitally controlled without any D/A converter. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using high speed on-off valve, and to give a criterion for the stability of this system. To do this, the nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are examined theoretically and experimentally. Consequently, the availability of the proposed method is confirmed well.

Constant Speed Control of Shaft Generating System Driven by Hydrostatic Transmission Using a PWM Controlled High Speed on/off Valve for Ship Use (고속 전자밸브 PWM제어에 의한 유압구동식 선박용 축발전장치의 정속제어)

  • 정용길;신민수;이일영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.6
    • /
    • pp.1374-1381
    • /
    • 1994
  • This study suggests a new type shaft generating system driven by hydrostatic transmission suitable for small size vessels. In this system, the hydraulic motor speed is controlled by displacement adjustment using a 3-way high speed on/off valve. The 3-way high speed valve is operated by PWM control signal. In this study, a digital robust servo control algorithm is applied to the controller design of the system. By experiments and numerical computations, the frequency variation characteristics of the generating system under various disturbances are investigated. Conclusively, it is said that the shaft generating system proposed in this study shows excellent control performances.