• Title/Summary/Keyword: OHU

Search Result 16, Processing Time 0.02 seconds

Effects of Intramuscular Fat on the Sensory Characteristics of M. longissimus dorsi in Japanese Black Steers as Judged by a Trained Analytical Panel

  • Okumura, Toshiaki;Saito, Kaoru;Nade, Toshihiro;Misumi, Satsuki;Masuda, Yasuhisa;Sakuma, Hironori;Nakayama, Sachio;Fujita, Kazuhisa;Kawamura, Tadashi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.4
    • /
    • pp.577-581
    • /
    • 2007
  • The effects of intramuscular fat on the sensory characteristics of M. longissimus dorsi in Japanese Black steers were investigated by a trained analytical panel (average 13.4 panelists). Five sets (10 head) of artificial identical twins were divided into 2 groups, high level of intramuscular fat group (HG) which utilized the fattening method of increasing intramuscular fat and low level of intramuscular fat group (LG) which did not use the above method. Regarding M. longissmus dorsi which was produced for use in the sensory evaluation, crude fat contents of HG and LG was 25.8% and 23.2% respectively (p<0.05). Warner-Bratzler shear force, water holding capacity, cooking loss and fatty acid composition of HG and LG were similar between the two groups. M. Longissimus dorsi taken from HG and LG were tested for their sensory characteristics by a trained panel. HG was given higher points for juiciness than LG (p<0.05). There were no significant differences for tenderness and flavor between the two groups. Overall acceptability which synthesized each of the sensory characteristics of HG and LG were 5.04 and 4.69 points respectively (p = 0.05). These results suggested that juiciness increased with the increase of intramuscular fat, and this raised the overall acceptability of M. longissimus dorsi.

The Development of Rotoless Electronic Circulating Pump System with Internal Three Way Valve for Boiler - Objective for the 1st Year : Development of New Housing with Internal Three Way Valve - (보일러용 3way valve내장형 rotoless 전자식순환펌프 시스템의 개발 - 1차년도 목표 : 3way valve 내장형 하우징의 개발 -)

  • Han, J.W.;Kum, S.M.;Ryu, B.H.;Lee, C.E.;Ohu, S.C.;Yim, J.S.
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.97-112
    • /
    • 1996
  • The purpose of research is to complement the circulating pump of gas boiler for the domestic and to develop a pump housing with internal three way valve: Housing and three way valve have been apart in the existing pump system. Based on the experimental result on can-typed circulating pump with existing housing, a new housing with internal three way valve was designed and manufactured. The performance of can-typed circulating pump with the new housing, and the performance of circulating pump of boiler system were tested. As a result ot the test, the new housing with internal three way valve has been excellent in respect of pump performance, weight and manufacturing cost. So It is expected to have an effect of import substitution.

  • PDF

A Study on Pressure Drop Through The Porous Metal (소결금속층(燒結金屬層)에서의 압력강화(壓力降下)에 관한 연구(硏究))

  • Ohu, Su-Cheol
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.43-50
    • /
    • 1992
  • This study has been conducted to provide fundamental knowledge of the characteristics of pressure drop through porous metal by experimental investigation. Pressure drop of air passing through porous metal was measured. The influences of porosity and flow velocity on pressure drop were investigated and in view of friction factor, the experimental data was compared with theorical equation as known to Ergun's equation concerning unconsolid packed bed. The result of this study are as follows. The pressure drop was increased with increasing the flow velocity and at the same flow velocity with decreasing the porosity(decreasing the particle diameter), In Particular, the experimental equation for the pressure drop was derived using the particle diameter, matrix diameter and matrix thickness. The experimental data were correlated well(mean deviation ${\pm}15%$ )with the present empirical dimensionless equation.

  • PDF

Design of Living Lab with BEMS via EnergyPlus for Scheduling HVAC System Considering Occupancy Schedule (리빙랩(Living-lab) 설계를 위한 BEMS 및 EnergyPlus 기반 재실 여부 고려 공조계획 도출)

  • Lee, Jae-Ho;Kim, Sung-Joong;Yoon, Yong-Tae;Kim, Kyoung-Hoon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_3
    • /
    • pp.1135-1145
    • /
    • 2022
  • Due to increase in concerns related to the climate change, state-wide promotion of the carbon neutrality has been in progress thus far. Smart City could be one of the measures as the initiative to mitigate the missions process. The primary purpose of Smart City can be summarized to be maximization of the social net-beneift to be returned for the local citizens and derivation of the optimal pattern of the energy consumption could belong to one of the elements included in the net-benefit. Currently, the energy consumption by the buildings has been determined to be responsible for the greatest consumption among the sectors considered to be energy-intensive. Moreover, considering the fact that the consumption by operations of HVAC is responsible for nearly 40% in the commercial buildings, it is virtually not possible to optimize schedules for the energy consumption with considerable deliverables from the perspective of the urban planners. Thus, the methods to implement the optimal schedules for the HVAC commissioned with the OHUs were concluded to be the suitable candidate resources for the simulation by EnergyPlus capable of monitoring the thermal changes in each subject space in the present research.

An Experimental Study on the Augmentation of Heat Transfer by Impinging Air Jets with Swirl (충돌선회분류(衝突旋回噴流) 열전달증진(熱傳達增進)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Ohu, Su-Cheol;Park, Sung-Soo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 1993
  • This Paper deals with the experimental study of the axisymmetric air jet impinging vertically on the flat heating surface with and without swirl. The purpose of this study is to investigate the characteristics of flow, augmentation of heat transfer rate, turbulent intensity, and the comparison of heat transfer rate, the optimal swirling condition about the swirl and nonswirl axisymmetric air jet. In order to augment the heat transfer on the flat heating surface without introducing any additional power, the technique used in the present work was placement of twisted tape inserted pipe in front of the nozzle exit in order to make a swirl. The effect of swirl degree is investigated in case of S=0., 0.056, 0.111, 0.222 and the velocity of the jet was 14, 20, 26, 32, 38, 44m/s. The distance between the nozle exit and the stagnation point on the impinging plate was the H/D=$1{\sim}14$. In order to analyze of the flow structure which increase heat transfer, the velocity and the turbulent intensity of the axisymmetric jet was measured by a hot wire anemometer according to the swirl number and H/D.

  • PDF

Changes in Chemical Components of Stagnant Water by Tillage Method and Amount of Nitrogen Application in Wet Seeded Rice after Barley Straw Mulching (논에 보리짚 시용시 경운방법 및 질소시비량에 따른 논물의 화학성분 변화)

  • Cheong, Jin-Il;Choi, Min-Gyu;Noh, Tae-Hwan;Lee, Jung-Ho;Kwon, Tae-Ohu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.4
    • /
    • pp.411-419
    • /
    • 1996
  • The experiment was aimed to determine a change of chemical component in irrigatted water based on different tillage methods and nitrogen rates under mulching of barley straw in direct seeded rice. There was no difference in water pH of no-tillaged plot but high in tillaged plot until 10 days after treatment. The electric conductivity(EC) of the water was higher in no-tillaged plot than in tillaged plot. However, the dissolved oxygen content was vice versa. The content of NH$_4$-N was high in higher application rate of N fertilizer without the tillage. Mean while, NO$_3$-N content was highly affected by no-till aged plot particularly in between application time and fertilizer rate but not in tillaged plot. There was higher in P043- content with the no-tillaged plot compared to the tillaged plot. It was big difference with higher application rate of the fertilizer. Soil cations were high in much application of fertilizer without the tillage.

  • PDF