• Title/Summary/Keyword: OAR

Search Result 119, Processing Time 0.022 seconds

Comparison of Dose Distribution between the Techniques of Non-small Cell Lung Cancer (비소세포폐암의 방사선 치료기법간의 선량분포의 비교)

  • Lee, Seung-chul;Kim, Young-jae;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.233-239
    • /
    • 2016
  • Comparison of the dose aspect that radiation therapy treatments using IMRT, tomotherapy, mArc (modulated arc therapy). The experimental subject is non-small cell lung cancer patient. The prescription dose is 58.0 Gy to the volume of PTV(planning target volume). and spinal cord, esophagus, and liver organ is the normal organ(OAR, organ at risk). Average PTV value is 57.60 Gy in mArc and 61.04 Gy in tomotherapy and 58.95 Gy in IMRT. The average dose of the Esophagus is 2.84 Gy in m-Arc, 5.14 Gy in tomotherapy, 1.84 Gy in IMRT. The average dose of the Liver is 19.44 Gy in m-Arc, 12.22 Gy in tomotherapy, 21.97 Gy in IMRT. The average dose of the Spinal cord is 5.72 Gy in m-Arc, 7.08 Gy in tomotherapy, 6.15 Gy in IMRT. Results of this study is no significant difference between mArc and tomotherapy and Linac based IMRT in dose study and also, mArc's dose coverage and dose volume histogram is better than IMRT and tomotherapy. but, This study is limited to a disease of cancer. in addition, fewer number of groups. The wide range the more research can be developed patient-specific treatment techniques and be applied to the patients

Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT (비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Shim, Jae-Goo;Park, So-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

Assessment of Dose Distributions According to Low Magnetic Field Effect for Prostate SABR

  • Son, Jaeman;An, Hyun Joon;Choi, Chang Heon;Chie, Eui Kyu;Kim, Jin Ho;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.26-31
    • /
    • 2019
  • Background: Stereotactic ablative radiotherapy (SABR) plans in prostate cancer are compared and analyzed to investigate the low magnetic effect (0.35 T) on the dose distribution, with various dosimetric parameters according to low magnetic field. Materials and Methods: Twenty patients who received a 36.25 Gy in five fractions using the MR-IGRT system (ViewRay) were studied. For planning target volume (PTV), the point mean dose ($D_{mean}$), maximum dose ($D_{max}$), minimum dose ($D_{min}$) and volumes receiving 100% ($V_{100%}$), 95% ($V_{95%}$), and 90% ($V_{90%}$) of the total dose. For organs-at-risk (OARs), the differences compared using $D_{max}$, $V_{50%}$, $V_{80%}$, $V_{90%}$, and $V_{100%}$ of the rectum; $D_{max}$, $V_{50%}$, $V_{30Gy}$, $V_{100%}$ of the bladder; and $V_{30Gy}$ of both left and right femoral heads. For both the outer and inner shells near the skin, $D_{mean}$, $D_{min}$, and $D_{max}$ were compared. Results and Discussion: In PTV analysis, the maximum difference in volumes ($V_{100%}$, $V_{95%}$, and $V_{90%}$) according to low magnetic field was $0.54{\pm}0.63%$ in $V_{100%}$. For OAR, there was no significant difference of dose distribution on account of the low magnetic field. In results of the shells, although there were no noticeable differences in dose distribution, the average difference of dose distribution for the outer shell was $1.28{\pm}1.08Gy$ for $D_{max}$. Conclusion: In the PTV and OARs for prostate cancer, there are no statistically-significant differences between the plan calculated with and without a magnetic field. However, we confirm that the dose distribution significantly increases near the body shell when a magnetic field is applied.

Position of Hungarian Merino among other Merinos, within-breed genetic similarity network and markers associated with daily weight gain

  • Attila, Zsolnai;Istvan, Egerszegi;Laszlo, Rozsa;David, Mezoszentgyorgyi;Istvan, Anton
    • Animal Bioscience
    • /
    • v.36 no.1
    • /
    • pp.10-18
    • /
    • 2023
  • Objective: In this study, we aimed to position the Hungarian Merino among other Merinoderived sheep breeds, explore the characteristics of our sampled animals' genetic similarity network within the breed, and highlight single nucleotide polymorphisms (SNPs) associated with daily weight-gain. Methods: Hungarian Merino (n = 138) was genotyped on Ovine SNP50 Bead Chip (Illumina, San Diego, CA, USA) and positioned among 30 Merino and Merino-derived breeds (n = 555). Population characteristics were obtained via PLINK, SVS, Admixture, and Treemix software, within-breed network was analysed with python networkx 2.3 library. Daily weight gain of Hungarian Merino was standardised to 60 days and was collected from the database of the Association of Hungarian Sheep and Goat Breeders. For the identification of loci associated with daily weight gain, a multi-locus mixed-model was used. Results: Supporting the breed's written history, the closest breeds to Hungarian Merino were Estremadura and Rambouillet (pairwise FST values are 0.035 and 0.036, respectively). Among Hungarian Merino, a highly centralised connectedness has been revealed by network analysis of pairwise values of identity-by-state, where the animal in the central node had a betweenness centrality value equal to 0.936. Probing of daily weight gain against the SNP data of Hungarian Merinos revealed five associated loci. Two of them, OAR8_17854216.1 and s42441.1 on chromosome 8 and 9 (-log10P>22, false discovery rate<5.5e-20) and one locus on chromosome 20, s28948.1 (-log10P = 13.46, false discovery rate = 4.1e-11), were close to the markers reported in other breeds concerning daily weight gain, six-month weight, and post-weaning gain. Conclusion: The position of Hungarian Merino among other Merino breeds has been determined. We have described the similarity network of the individuals to be applied in breeding practices and highlighted several markers useful for elevating the daily weight gain of Hungarian Merino.

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF

An Empirical Study on the Changes in Tax Payments under Consolidated Tax Return (연결납세와 개별납세간의 법인세부담액 차이에 대한 실증연구)

  • Jeong, Jae-Yeon;Shin, Hyun-Geol
    • 한국산학경영학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.101-123
    • /
    • 2004
  • This study examines empirically the significant changes in tax payments when the consolidated tax return is introduced in the future. We estimate the consolidated tax payments under the eight cases which are classified as such : whether only 100% ownership subsidiaries should be included or 80% and over, whether all subsidiaries should be included or only subsidiaries with loss, and whether unrealized profits from intercompany transactions should be excluded or not. After estimating the consolidated tax payments, we test the difference between the consolidated tax payments and the sum of the individual tax payments of the subsidiaries. The results of the test show that the consolidated tax payments are significantly less than the sum of the individual tax payments of the subsidiaries. We interpret that the inclusion of the losses of the subsidiaries in the consolidated tax base makes the tax payment decrease. Based on our analysis about 3.8 billion Won per each parent company would decrease due to the introduction of the consolidated tax return. And we find that under the mandatory consolidated tax return system the significant difference between the consolidated and individual tax payment exists except that the only 100% ownership subsidiaries are included and unrealized profits from intercompany transactions are not excluded. However, when the parent companies have the discretion to select the consolidated subsidiaries, the consolidated tax payments are significantly less than the sum of the individual tax payments of the subsidiaries regardless of the ownership percentage, inclusion of the loss of the subsidiaries and exclusion of the unrealized profits.

  • PDF

Nd, Sr and Noble Gas Isotopic Compositions of Alkali Basaltic Rocks and Mantle Xenoliths in the Baegryongdo (백령도에 분포하는 알칼리 현무암과 맨틀 포획암의 Nd-Sr과 영족기체 동위원소 조성)

  • ;Nagao Keisuke;;Sumino Hirochika
    • Economic and Environmental Geology
    • /
    • v.35 no.6
    • /
    • pp.523-532
    • /
    • 2002
  • The rare earth elements (REE) and Nd, Sr and noble gas isotopic compositions eHer'He, 4$^{\circ}$Arp6Ar) for the Quaternary alkali basaltic rocks and mantle xenoliths in the basaltic rocks from the Baegryongdo were investigated to decipher the origin of alkali basaltic magma and xenolith beneath the Sino-Korean craton. Analytical results are summarized as follows; (1) The alkali volcanic rocks with voluminous xenoliths which are represented by the Mg-olivine and clinopyroxene dominant spinel-lherzolite in the Baegryongdo consist mainly of the basalt-mugearite and basaltic andesite. (2) The REE pattern of alkali basaltic rocks characterized by high HREE is similar to that of oceanic island basalt (OlB). Relatively concordant REE patterns of the basaltic rocks suggest that the alkali basaltic magma be formed by the identical source materials. (3) The Nd-Sr isotopic data of the alkali basaltic rocks suggest that the alkali basaltic magma be originated from the depleted mantle source with a little contamination of the continental crustal materials. (4) The $^3$He/ $^4$He ratios in olivines of xenoliths ranging from 5.0${\pm}$1.lRa to 6.7${\pm}$1.3Ra are lower than that of MORB (ca. 8.0Ra). It suggest that the xenolith be derived from the subcontinental lithospheric mantle. However, the high $^3$Her'He value of 16.8${\pm}$3.IRa at 1800$^{\circ}$C fraction (sample no OL-7) might be resulted from the post-eruptive cosmogenic $^3$He. The 4OAr/ 36 Ar ratios in olivines of mantle xenoliths are comparable to that of atmospheric argon, and are much lower than that of the MORB type mantle. These facts can lead to conclusion that the olivine of the xenolith in the Baegryongdo is affected by the post-eruptive atmospheric contamination during the slow degassing process.

Analysis on the Decrease of Planning Target Volume in the Case of Lung Radiation Surgery with the Application of Respiratory Gated Radiotherpy Method (폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.263-268
    • /
    • 2008
  • The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were $16.88{\pm}9.97%$ in the bronchus, $34.13{\pm}19.15%$ in the spinal cord, $28.42{\pm}18.49%$ in the chest wall and $32.48{\pm}16.66%$ in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.

  • PDF

Robust Planning of Intensity-modulated Proton Therapy for Prostate Cancer (전립선암 치료를 위한 세기조절 양성자 로버스트 치료계획)

  • Park, Su Yeon;Kim, Jong Sik;Park, Ju Young;Park, Won;Ju, Sang Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.25-31
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the dosimetric properties of robust planning strategy for plain intensity-modulated proton therapy (IMPT) taking into account of the uncertainties of effective proton range and set up error as compared to photon intensity-modulated radiation therapy (photon-IMRT) in prostate cancer treatment. Materials and Methods: The photon-IMRT (7 beams, step & shoot), plain-IMPT (2, 4, and 7 portals), and robust- IMPT plans, which was recalculated the plain-IMPT based on the uncertainties of range error (${\pm}5%$) and set up error (0.5 cm), were evaluated for five prostate cancer patients prescribed by 70 Gy/35 fractions. To quantitatively evaluate the dose distributions, several parameters such as maximum dose, minimum dose, mean dose, conformity index (CI), and homogeneity index (HI) for PTV as well as dose-volume index of VxGy for OARs were calculated from dose-volume histograms. Results: Robust-IMPT showed superior dose distributios in the PTV and OARs as compared to plain-IMPT and photon-IMRT. Like plain-IMPT, robust-IMPT were resulted in dose fluctuation around OARs, while better homogeneity and conformity in PTVs and lower mean dose in OARs as compared to photon-IMRT. Conclusion: In consideration with the effective range correction and set up movement using robustness in IMPT plan, the dosimetric uncertainties from plain-IMPT could substantially reduce and suggest more effective solutions than photon-IMRT in prostate cancer treatment.

  • PDF

A Study on the Sailing Speed of Ancient Ships - especially on the average speed and the effect of the wind, the tide, and the man-power at the oar - (고대 선박의 항해속도 연구 - $\ll$고려도경$\gg$을 중심으로-)

  • Yoon, Il-Young
    • Journal of National Security and Military Science
    • /
    • s.7
    • /
    • pp.155-231
    • /
    • 2009
  • Xu-Jing(徐競) an official of the Song(宋), a medieval Kingdom of China, wrote a book titled $\ll$Koryo Tu Jing(高麗圖經)$\gg$ which explains his travel to the Koryo as a member of diplomatic mission in 1123. $\ll$Koryo Tu Jing$\gg$ is the record of his personal experience in Koryo with many explanatory illustrations and especially contains 5 months' voyage record of his diplomatic fleet. His fleet set sail at a port located in the Ding Hai Xian(定海縣), Ming Zhou(明州) via a few islands of Koryo [Hyup Kye San(俠界山) , the Kun San Do(群山島) , the Ja Yon Do(紫燕島) , the Keup Su Mun(急水門) in Kang Hwa Gun(江華郡) and the Hap Gul(蛤窟) ] and finally arrived the Port Ye Song Hang(禮成港) . According to the Xu-Jing's record his fleet sailed the sea with the help of the favorable seaward winds and tides as the usual way of ancient sailing. The Xu- Jing's Fleet sailed the sea between the Mei Cen(梅岑), Ming Zhou(明州) of China and the Hyup Kye San(俠界山) of Koryo from about 5:00 a.m., May 24th(of the lunar calendar) to about 5:00 p.m., June 2nd. At this section, the average speed of the seaward winds was 19.45km/h and the average speed of the fleet which sailed only by the power of the winds was 6.29km/h. This means that 32.3% of the favorable seaward winds' speed was equal to the speed of the ancient fleet which sailed only by the power of the favorable seaward winds. The fleet sailed the sea between the Ja Yon Do(紫燕島) and the Keup Su Mun(急水門) from about 9:00 a.m., June 10th to about 1:00 p.m., the same day. At this section the fleet sailed by the power of tides in addition to the favorable seaward winds without oaring. The average speed of the winds was not different from that of former section and the average speed of the tides was 1.937km/h. And at this section the average speed of the fleet increased by 0.41km/h than that of the former section. This means that 21.1% of the speed of the tides was equal to the increased speed of the ancient fleet by virtue of the tides. The fleet sailed the sea between Keup Su Mun(急水門) and the Hap Gul(蛤窟) from about 1:00 p.m., June 10th to about 3:00 p.m., the same day. At this section, there were no seaward winds and the fleet sailed only by the powers of tides and oaring. And at this section, the tide increased the average speed of the fleet by 0.3114km/h and the fleet could sail at the speed of 4.3km/h. So we can conclude that the average speed of ancient fleet without any influences of the seaward winds and tides was 3.98 km/h. We can make use of the various sailing speeds of ancient fleets when judging their maritime activities. If we make use of the various sailing speeds of the ancient fleets as calculated in this article, we will be able to get various important informations about the certain ancient fleet's maritime maneuver. For example, we can infer the sailing routs of a certain fleet and the time when the fleet passed a certain spot by making use of the various sailing speeds of the ancient fleet. In this article I did not take account of the shapes of ships that consist of the ancient fleets and the sizes of the various ships and fleets. It was because that such factors would not change the foresaid conclusions seriously.

  • PDF