• Title/Summary/Keyword: Nursing error

Search Result 154, Processing Time 0.028 seconds

Accuracy Evaluation of the Alternative Site Blood Glucose Test Using Error Grid (에러그리드를 사용한 대체부위 혈당검사의 유용성 검증)

  • Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • Blood glucose information is important for self regulation in daily life, but the frequency of self test remains to be only 17%(9 tests/month) in Korea, mainly due to pain during blood sampling. The present study tried to validate the clinical efficacy of the forearm as an alternative sampling site with minimized pain. Capillary blood was sampled both on the index finger($G_F$) and the forearm($G_A$), immediately followed by glucose measurements in 531 subjects, 25 who visited the Health Enhancement Center of C University Hospital, then venous blood($G_V$) was sampled for glucose test. The blood glucose concentration measured on the forearm was closer to the venous glucose than on the finger. The mean difference between $G_V$and $G_F$ was only 10 mg/dL well within the internationally accepted error limit. Error grid analyses of $G_F-G_V$, $G_A-G_V$ and $G_A-G_F$ revealed that the number of data points in regions A and B took 100%, 99.8%, and 97.9%, respectively. These results demonstrate the forearm blood glucose test is not only accurate but also clinically valid. Therefore, the forearm blood glucose test can be a useful way of self managing the chronic diabetes with minimized sampling pain.

Development of Measuring Tool for Health Promotion Behavior of Nurses (간호사의 건강증진행위 측정도구 개발)

  • Kim, Min-young;Choi, Soon-Ok;Kim, Eun-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.138-147
    • /
    • 2021
  • The purpose of this study was to develop a measuring tool for the health promotion behavior of Korean nurses. This would address the lack of a proven tool that reflects the nature of the nurses' nursing environment. This study was conducted on 530 nurses from January to December 2019. A literature review and focus group interview were conducted, data analysis was carried out to measure validity and reliability, and the conceptual framework was constructed by applying the IMB model. Five factors namely self-concept (2 questions), hospital life management (4 questions), knowledge and information regarding health (5 questions), physical and mental stress management (3 questions), and work adaptation (2 questions) were framed into 16 questions. The model fit was 346.23 (��<.001), Parsimonious Normed Fit Index (PNFI) was 0.60, and Parsimonious Comparative Fit Index (PCFI) was 0.63, which met the acceptance criteria, and the Root Mean Square Error of Approximation (RMSEA) was 0.10. Goodness of Fit Index (GFI) was 0.88, Comparative Fit Index (CFI) was 0.85, and Incremental Fit Index (IFI) was 0.85 which were found to be acceptable as per the applicable standards. All items had a Cronbach's �� score of .85, which ensured stable reliability. The nurse's health promotion behavior measurement tool developed in this study will be used to measure the nurse's health promotion behavior in terms of nursing practice which will help in understanding the broad contours of this behavior.

Performance Appraisal and Job Rotation of the Nurse In a General Hospital (간호사 인사관리 제도에 관한 연구)

  • Kwon, Young-Hee;Lee, Myung-Ha
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.3
    • /
    • pp.425-444
    • /
    • 1999
  • The purpose of this study is to survey evaluation of the nurse on the current Performance Appraisal System. the need for future performance of the nurse and the opinions about the job rotation, and suggest the direction of improvement by obtaining basic data to improve personnel management of the nurse in a hosipial, the subject of the investigation. The study was conducted self-reporting questionniare survey of 330 nurses working at C hospital located in Chonbuk Province and the data was collected from May 4. 1999 through May 14. The research used measuring instrument developed by researcher for evalution about the present performance appraisal. the need for the future performanc appraisal system and the opinion of job rotaion. The analysis of the collected data was computerized using SPSS/PC+ program, calculated frequency, percentage, the mean and standard deviation and used Pearson, s Correlation Coefficients, t-test, chi- square test. Major findings are as follows. 1) As for the purpose of the current performanc appraisal, the appraiser recognized it as a security of promotion standard, while the employee saw it as a means for control as guidance and supervison of work. 2) With regard to use the result of the present performance appraisal, appraiser picked ambiguous appraisal standard, employees recognized unilateral evaluation of superior eliminated the participation of them as the highest priority. 3) In relation to the current criteria for promotion of the nurse, both appraisers and employees placed more weight on the length of clinical than performance appraisal score. 4) There is much possibility of the appraiser making an error to evaluate considering the length of performance appraisal. 5) Both appraisers and employees indicated that prospective result of performance appraisal should be used for the ability development & motivation of the individual. 6) Concerning employee's participation for performance appraisal both sides wanted by far more participation. 7) Regarding the most ideal appraisal method, both parties favored most the way added up the evaluation of the head nurse and peer review and followed by the manner the revaluation of the head nurse by considering self-evaluation. 8) As to the individual interview after the appraisal, more than 60% of appraisers responded it's not necessary, while above 88.5% of employees answered it is essential so that it is showed significantly difference between the appraisers and the employees. 9) As far as open of the evaluation result is concerned. 75% of the appraiser were against it but 80% of the employee were for it so that it showed significantly between them. The most principal reason that the employee want is that it motivates the individual's ability development and the fairness of the appraisal increases. 10) Whether the periodical rotation is necessary or not, 80% of appraisers and employees answered it's necessary, however, over 70% of them did not want the rotation. 11) Work-group Cohesiveness level within the nursing unit was attentive different from desire of the rotation, that is, the work group cohesiveness level of nurses wanting rotation was significantly lower than that of the group not desiring it.

  • PDF

A Study on the Analysis of Performance Appraisal Tools for Nurses (간호사의 근무평정도구 분석에 관한 연구)

  • Park, Hee-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.10 no.1
    • /
    • pp.25-36
    • /
    • 2004
  • Purpose: Nursing puts much weight en the organization of hospital. Therefore it is necessity to improve nursing care. One of the most important things is to secure confident nurses and to develop nurse' potentiality. It directs nurse evaluation system. The concept of "performance appraisal tools" is extremely important in evaluation system. Therefore, the purpose of this study aims to define performance appraisal process. Method: In order to do this, two main study has been observed interviewing appraisers and employees in-depth and analyzing performance appraisal tools of seven hospitals and analysed validity, reliability, acceptability and practicability. Result: The result of this study can be summarized as follows; Firstly, the result of analysis of performance appraisal tools. Regard to validity, Hospitals had a typical goal, but had not put to practice use. Regard to reliability, 1) Appraisal rule had been focused on appraiser's error, how to avoid. 2) 5 hospitals accessed nurses with relative rating and 2 hospitals with absolute rating both in practice. 3) 3 hospitals informed nurses the result of performance appraisal but 4 hospitals did not. 4) All hospitals in this study had conducted superiors rating. Regard to acceptability, 1)Rating scale method had been implemented by 6 hospitals and among those conducted beth ranking method and descriptive method. 2) Most hospitals had focused on personal traits in performance appraisal factors. Regard to practicality, The term of appraisal took $10{\sim}14$ days; performance appraisal happened 1 or 2 times per year; appraisal factors were based on 10 different items. Secondly, the result of in-depth interview with head nurses and staff nurses Regard to validity, head nurses and nurses wared that the goal of performance appraisal is to develop nurse's ability. Regard to reliability, head nurses pointed out that they were doubt of the justice of performance appraisal and they should have got training. Nurses insisted that raters should have been trained due to lack of qualification of appraiser; Head nurses and nurse proposed to convert form relative rating to absolute rating; to inform the result of appraisal; to implement peers rating. Regard to acceptability, One of the critical problems of performance appraisal tools was abstract of appraisal factors ; Lack of job analysis. Regard to practicality, Head nurses used to take overtime for appraisal. There was only a little respond despite of their efforts. Nurses questioned that appraisal tools exist for only appraisal; there was less cost-effectiveness. Conclusion: Based en these findings, it could be suggested to improve the performance appraisal tools for nurses evaluation. Firstly, it is necessary to describe goal of performance appraisal clearly set up, so that nurses could improve their positive word performance and develop their potentiality. Secondly, it is necessary to obtain various training on raters, implement absolute rating and inform the result of appraisal to nurses and use peers rating. Thirdly, it is necessary to convert from rating scale method to management by objectives or behaviorally anchored rating scale and take measurable appraisal factors based en job analysis. Finally, it is necessary to reduce the appraisal cost but increase effectiveness of performance appraisal.

  • PDF

Triage Accuracy of Pediatric Patients using the Korean Triage and Acuity Scale in Emergency Departments (한국형응급환자분류도구를 적용한 응급실에서 소아 환자의 중증도 분류 정확성)

  • Moon, Sun-Hee;Shim, Jae Lan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.626-634
    • /
    • 2018
  • This retrospective study investigates the accuracy of triage procedures for pediatric patients in emergency departments (EDs) using the Korean Triage and Acuity Scale (KTAS). The study includes 250 randomly selected initial nursing records and clinical outcomes of pediatric patients who visited one regional ED or a local ED from October 2016 to September 2017. The collected data were analyzed by a qualified expert to determine the true triage score. The accuracy of triage was defined as the agreement between the triage score of the emergency nurses (ENs) and the true triage score as determined by the expert. Based on expert comments, the cause of the triage error was analyzed and the KTAS score was compared with the discharge, length of stay (LOS), and medical cost. The results showed that the degree of agreement in the triage score between the experts and the ENs was excellent (weighted kappa=0.77). Among the causes of triage discordance, the most frequent was the incorrect application of vital signs to the KTAS algorithm criteria (n=13). Patients with high severity KTAS levels 1 and 2 were discharged less often (${\chi}=43.25$, p<0.001). There were significant differences in the length of stay (F=12.39, p<0.001) and cost (F=11.78, p<0.001) between KTAS scores when adjusting for age. The results of this study indicate that KTAS is highly accurate in EDs. Hence, the newly developed triage tool is becoming well established in Korea.

Medication Errors in Chemotherapy Preparation and Administration: a Survey Conducted among Oncology Nurses in Turkey

  • Ulas, Arife;Silay, Kamile;Akinci, Sema;Dede, Didem Sener;Akinci, Muhammed Bulent;Sendur, Mehmet Ali Nahit;Cubukcu, Erdem;Coskun, Hasan Senol;Degirmenci, Mustafa;Utkan, Gungor;Ozdemir, Nuriye;Isikdogan, Abdurrahman;Buyukcelik, Abdullah;Inanc, Mevlude;Bilici, Ahmet;Odabasi, Hatice;Cihan, Sener;Avci, Nilufer;Yalcin, Bulent
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1699-1705
    • /
    • 2015
  • Background: Medication errors in oncology may cause severe clinical problems due to low therapeutic indices and high toxicity of chemotherapeutic agents. We aimed to investigate unintentional medication errors and underlying factors during chemotherapy preparation and administration based on a systematic survey conducted to reflect oncology nurses experience. Materials and Methods: This study was conducted in 18 adult chemotherapy units with volunteer participation of 206 nurses. A survey developed by primary investigators and medication errors (MAEs) defined preventable errors during prescription of medication, ordering, preparation or administration. The survey consisted of 4 parts: demographic features of nurses; workload of chemotherapy units; errors and their estimated monthly number during chemotherapy preparation and administration; and evaluation of the possible factors responsible from ME. The survey was conducted by face to face interview and data analyses were performed with descriptive statistics. Chi-square or Fisher exact tests were used for a comparative analysis of categorical data. Results: Some 83.4% of the 210 nurses reported one or more than one error during chemotherapy preparation and administration. Prescribing or ordering wrong doses by physicians (65.7%) and noncompliance with administration sequences during chemotherapy administration (50.5%) were the most common errors. The most common estimated average monthly error was not following the administration sequence of the chemotherapeutic agents (4.1 times/month, range 1-20). The most important underlying reasons for medication errors were heavy workload (49.7%) and insufficient number of staff (36.5%). Conclusions: Our findings suggest that the probability of medication error is very high during chemotherapy preparation and administration, the most common involving prescribing and ordering errors. Further studies must address the strategies to minimize medication error in chemotherapy receiving patients, determine sufficient protective measures and establishing multistep control mechanisms.

Evaluation of Visual-Motor Integration in Elderly Patient with Diabetes Mellitus (노인 당뇨환자의 시각-운동 통합능력 평가)

  • Yun, Hyo Soon;Kim, Mi Ae;Kim, Mi Han;Suh, Soon-Rim;Kim, Hong
    • 한국노년학
    • /
    • v.31 no.3
    • /
    • pp.641-652
    • /
    • 2011
  • The purpose of this study was to investigate the ability of visual-motor integration (VMI) in elderly patient with diabetes mellitus(DM). Male elderly (from 65 to 70 years old) with DM and non-DM disease were participated in this study. Participants were divided into three group (n=30 in each group): the control group, non-DM group, and DM group. Data were collected through VMI-3R questionnaires and interviews. Statistical differences among groups were determined by one-way ANOVA followed by Duncan Post-hoc test and results were expressed the mean ± S.D. or percentage (%). The present results showed that the score of both VMI 24 and VMI 50 in DM group were statistically lower than both the control and Non-DM groups. Also, the lower rate of correct and higher rate of error in VMI-3R was observed in DM group compared to both the control and Non-DM groups. The item analysis of VMI-3R revealed that the most higher rate of error was observed in item 24 in all groups. Based on these results, this study suggests that DM might aggravate the function of visual-motor integration in male elderly.

Acceptance Measure of Quality Improvement Information System among Long-term Care Workers: A Psychometric Assessment (장기요양인력의 질 향상 정보시스템 수용 측정도구: 신뢰타당도 평가)

  • Lee, Taehoon;Jung, Young-il;Kim, Hongsoo
    • Research in Community and Public Health Nursing
    • /
    • v.28 no.4
    • /
    • pp.513-523
    • /
    • 2017
  • Purpose: We evaluated the psychometric properties of a questionnaire on the acceptance of the quality improvement information system (QIIS) among long-term care workers (mostly nurses). Methods: The questionnaire composes of 21 preliminary questions with 5 domains based on the Technology Acceptance Model and related literature reviews. We developed a prototype web-based comprehensive resident assessment system, and collected data from 126 subjects at 75 long-term care facilities and hospitals, who used the system and responded to the questionnaire. A priori factor structure was developed using an exploratory factor analysis and validated by a confirmatory factor analysis; its reliability was also evaluated. Results: A total of 16 items were yielded, and 5 factors were extracted from the explanatory factor analysis: Usage Intention, Perceived Usefulness, Perceived Ease of Use, Social Influence, and Innovative Characteristics. The five-factor structure model had a good fit (Tucker-Lewis index [TLI]=.976; comparative fit index [CFI]=.969; standardized root mean squared residual [SRMR]=.052; root mean square error of approximation [RMSEA]=.048), and the items were internally consistent(Cronbach's ${\alpha}=.91$). Conclusion: The questionnaire was valid and reliable to measure the technology acceptance of QIIS among long-term care workers, using the prototype.

Nurse and Patient's Experiences Regarding the Use of Electronic Informed Consent in Hospital: A Qualitative Study (의료기관에서 간호사와 환자의 전자동의서 사용 경험: 질적 연구)

  • Kim, Sun Hee;Kang, Hee Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.619-628
    • /
    • 2020
  • This study examined the experiences of users regarding their use of electronic informed consent in hospital. A qualitative descriptive study was conducted using focus groups and in-depth interviews with 30 Korean nurses and 27 patients. Data were collected from one university hospital. The responses were analyzed by qualitative content analysis. Most participants perceived the use of electronic informed consent as convenient and straightforward, as well as saving space and money. On the other hand, the participants stated that the system was unsatisfactory in part because of the occasional unexpected machinery error or malfunction. Some patients wished for function improvements related to the e-signature, making it more comparable to a handwritten signature, and the adjustability of the font size. The nurses wanted a wider implementation of electronic informed consent because it was not being used for all informed consent cases, resulting in confusion and an additional workload. For the use of an electronic informed consent system, it is important to minimize the inconvenience and to maximize the satisfaction of the users, including nurses and patients.

Development of usability evaluation index of convergence technology remote fluid monitoring device for non-face-to-face patient nursing system application and analysis of results (비대면 환자 간호시스템 적용을 위한 융합기술의 원격 수액모니터링 장치 사용성평가 지표 개발 및 결과 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.137-145
    • /
    • 2022
  • The usability evaluation of the remote fluid monitoring device, which was introduced to reduce the work of nurses and increase the efficiency, was performed due to the expansion of the non-face-to-face medical system. Remote fluid monitoring is a fusion of various technologies such as fluid measurement and analysis, error correction technology, and transmission technology. The range of use by users, the information they want to obtain, and the control device, etc. are wide, and the factors that evaluate the product are also diverse. Therefore, it is difficult to improve the product through evaluation. In this study, a quantitative index was developed to help improve the product for commercialization by conducting 20 usability evaluations in three areas of product stability, operability, and satisfaction with the remote sap monitoring system device. It was performed through infrared and load cell-type sap monitoring devices. In terms of stability, there was a difference in installation work such as fixing the pole of the device, and high satisfaction was shown for operability and accuracy. In terms of product satisfaction, the satisfaction of load cell devices was generally high.