• Title/Summary/Keyword: Numerical measurements

Search Result 1,095, Processing Time 0.025 seconds

Evaluation of Internal Settlement of Rockfill Dam under Construction (석괴댐의 축조 중 내부 침하 거동 평가)

  • Seo, Min-Woo;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.4
    • /
    • pp.45-52
    • /
    • 2010
  • The purposes of this research are to analyze the internal settlement behavior of Concrete Faced Rockfill Dam (CFRD) typed 'D dam' and to evaluate the stability of the 'D dam' during dam construction using internal settlement measurements and results of numerical analysis. The field measurements were obtained during dam construction period. The numerical analysis was also carried out for the same construction period. The numerical analysis focused mainly on prediction of stress and displacement behavior of 'D dam' during dam construction stage using input parameters obtained from laboratory tests, i.e. large triaxial tests. The behavior of 'D dam' was evaluated to be stable from comparing the results of field measurements and numerical analysis. A simple empirical equation is also presented to predict final settlement at the completion of dam construction, using settlement measurement monitored during dam embankment.

A Study on Lateral Deformation of Braced Cuts by Field Measurements and Numerical Analyses (현장계측과 수치해석을 이용한 흙막이벽체 수평변위 연구)

  • Kim, Dong-Gun;Bae, Kyu-An;Jun, Sang-Hyun;Yoo, Nam-Jae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.171-180
    • /
    • 2010
  • In this study, applicability of software used to analyze the lateral deformations and its shape of braced cuts, executed to excavate the ground for constructing the underground structures, was assessed by performing field measurements and numerical analyses and their behaviors were also compared with results of previous studies. Three typical sections, located at the construction site where the subway was on the process of construction at Suwon city in Gyeonggido, were chosen and the data of field measurement at those sections were collected. Numerical analyses with FEM technique of using the software PLAXIS and elasto-plastic approach of using the software MIDAS were performed. In general, the deformed shapes of braced cut, obtained from numerical approaches, were in relatively good agreements with results from field measurements. For sections of A-A and B-B, measured values were greater than analyzed ones whereas they were in relatively good agreements in the section C-C. As results of comparing the values from the measurements and the estimations, they were found to be close to each other so that numerical approaches were assessed to be appropriate to estimate the lateral deformation. The numerical technique with FEM was preferred to use because it estimated closer to the measurements than the elasto-plastic approach.

  • PDF

A Semi-empirical Model for Microwave Polarimetric Radar Backscattering from Bare Soil Surfaces

  • Oh, Yi-Sok
    • Korean Journal of Remote Sensing
    • /
    • v.10 no.2
    • /
    • pp.17-35
    • /
    • 1994
  • A semi-empirical model for microwave polarimetric radar backscattering from bare soil surfaces was developed using polarmetric radar measurements and the knowledge based on the theoretical and numerical solutions. The microwave polarimetric backscatter measurements were conducted for bare soil surfaces under a variety of roughness and moisture conditions at L-, C-, and X-band frequencies at incidence angles ranging from 10` to 70`. Since the accrate target parameters as well as the radar parameters are necessary for radar scattering modeling, a complete and accurate set of ground truth data were also collected using a laser profile meter and dielectric probes for each surface condition, from which accurate measurements were made of the rms height, correlation length, and dielectric constant. At first, the angular and spectral dependencies of the measured radar backscatter for a wide range of roughnesses and moisture conditions are examined. Then, the measured scattering behavior was tested using theoretical and numerical solutions. Based on the experimental observations and the theoretical and numerical solutions, a semi-empirical model was developed for backscattering coeffients in terms of the surface roughness parameters and the relative dielectric constant of the soil surface. The model was found to yield very good agreement with the backscattering measurements of this study as well as with independent measurements.

A study on the cracking of tunnel lining by measurement and numerical analysis (계측 및 수치해석을 통한 터널 라이닝의 균열 원인 연구)

  • Hwang, Hak;Jung, Hun-Chul;Kim, Yu-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.33-40
    • /
    • 2001
  • In this research, the cracking of tunnel concrete lining was investigated and analyzed through long-term measurement and nonlinear numerical analysis. For one year after the casting of lining, the stresses and strains were measured by the sensors installed in hard rock tunnel lining. The measurements showed that only small stresses which were less than cracking stress occurred in every survey sections regardless of sensor directions. It could be induced that the external load applied to the lining was small or ignorable. Also, it was carried out short-term numerical analysis based on such site condition as ambient temperature, the- degree of overbreak and mold staying period. Long-term numerical analysis based on creep & shrinkage and nonlinear cracking was carried out. The output showed that construction condition and ambient environments could make the lining concrete crack without external loads. The cracks formed in this process does not indicate the structural instability of the tunnel.

  • PDF

Empirical numerical model of tornadic flow fields and load effects

  • Kim, Yong Chul;Tamura, Yukio
    • Wind and Structures
    • /
    • v.32 no.4
    • /
    • pp.371-391
    • /
    • 2021
  • Tornadoes are the most devastating meteorological natural hazards. Many empirical and theoretical numerical models of tornado vortex have been proposed, because it is difficult to carry out direct measurements of tornado velocity components. However, most of existing numerical models fail to explain the physical structure of tornado vortices. The present paper proposes a new empirical numerical model for a tornado vortex, and its load effects on a low-rise and a tall building are calculated and compared with those for existing numerical models. The velocity components of the proposed model show clear variations with radius and height, showing good agreement with the results of field measurements, wind tunnel experiments and computational fluid dynamics. Normal stresses in the columns of a low-rise building obtained from the proposed model show intermediate values when compared with those obtained from existing numerical models. Local forces on a tall building show clear variation with height and the largest local forces show similar values to most existing numerical models. Local forces increase with increasing turbulence intensity and are found to depend mainly on reference velocity Uref and moving velocity Umov. However, they collapse to one curve for the same normalized velocity Uref / Umov. The effects of reference radius and reference height are found to be small. Resultant fluctuating force of generalized forces obtained from the modified Rankine model is considered to be larger than those obtained from the proposed model. Fluctuating force increases as the integral length scale increases for the modified Rankine model, while they remain almost constant regardless of the integral length scale for the proposed model.

Investigation of Near.Transducer Errors in Acoustic Doppler Current Profiler Measurements Using Experimental and Numerical Method (ADCP 계기 부근에서 발생하는 관측 오차의 실험 및 수치모의에 의한 고찰)

  • Kim, Dong-Su;Kang, Boo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.944-951
    • /
    • 2011
  • This paper reports results of a joint experimental and numerical investigation of the causes of near-transducer errors due to the combined effect of acoustic and ADCP-induced flow disturbance near the ADCP transducer. The laboratory study focused on an isolated ADCP (deployment without boat). Measurements of the flow disturbance produced by the ADCP in vertical and horizontal planes were obtained acquiring measurements with an Acoustic Doppler Velocimeter (ADV). Concurrent measurements with ADCP and ADV were made to infer additional near-transducer effects in the ADCP measurements. The numerical investigation was designed to extend the inquiry on the near-transducer potential errors when the ADCP is deployed from a boat. Large Eddy Simulation (LES) was conducted to obtain the extent and magnitude of the disturbances induced by the drag acting on a boat-mounted ADCP and by the blockage effect of the instrument and boat. It is found the velocities measured by the ADCP are biased low and differ substantially from the undisturbed channel flow solution within a limited layer beneath the instrument.

An Analysis of Sound Pressure Distribution in a Reverberation Room and Comparisons with Measurements (잔향실의 음압분포해석 및 계측치와의 비교)

  • 김현실;김재승;강현주;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.669-674
    • /
    • 1997
  • A sound field in a reverberation room is analyzed by using numerical methods and the SPL distributions are compared to the measurements. In numerical predictions, the BEM is employed in the low frequency range, while sound ray tracing method is used for the high frequency range. In the BEM analysis, the surfaces of the empty reverberation room are assumed as rigid boundaries and the damping coefficients are estimated from the measured absorption coefficient. The comparisons with measurements for 100Hz shows good agreement. In the sound ray tracing analysis, the predicted energy decay are in excellent agreements with theoretical results. It is shown that the energy absorption by air damping plays an important role as frequency becomes higher.

  • PDF

A comparison of numerical simulations and full-scale measurements of snowdrifts around buildings

  • Thiis, Thomas K.
    • Wind and Structures
    • /
    • v.3 no.2
    • /
    • pp.73-81
    • /
    • 2000
  • Snowdrifts around buildings can cause serious problems when formed on undesirable places. The formation of snowdrifts is highly connected to the wind pattern around the building, and the wind pattern is again dependent on the building design. The shear stress on the surface and snowdrifting around different buildings are investigated through CFD analysis and compared to measurements. The computations of shear stress shows local minima in the same areas as snowdrifts are formed. The snowdrifting computations utilises a drift-flux model where a fluid with snow properties is allowed to drift through a fluid with air properties. An apparent dynamic viscosity of the snow/air mixture is defined and used as a threshold criterion for snowdrifting. The results from the snowdrifting computations show increased snow density where snowdrifts are expected, and are in agreement with previous large-scale snowdrift measurements. The results show that computational fluid dynamics can be a tool for planning building design in snowdrifting areas.

Frequency variation in construction stages and model validation for steel buildings

  • Aras, Fuat
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.647-662
    • /
    • 2016
  • This study aims to monitor the variation of modal frequencies of steel buildings during their construction sequence. In this respect, construction of a steel building is followed by vibration based measurements. The monitored building is a three-story educational building within a building group whose structural system consists of steel moment resisting steel frames and eccentric braces. Five different acceleration measurements in two perpendicular directions are taken on five different construction stages, starting from the erection of the columns and beams ending with the completion of the construction. The recorded measurements are transferred into frequency domain and the dominant frequencies for each case have been determined. The change in the dominant frequencies is evaluated with the existing construction stages and performed constructional works between the stages. The last measurement, performed on the building in service, revealed the first two dominant frequencies as mutual in X and Y direction, showing that these dynamic modes are torsional modes. This result is investigated by numerical analysis performed with finite element model of the building constructed for design purpose. Lower frequencies and different mode shapes are determined from numerical analysis. The reason of lower frequencies is discussed and the vibration survey is extended to determine the effects of an adjacent building. The results showed that the building is in strong relation with an adjoining building in spite of a designed construction joint.