• Title/Summary/Keyword: Numerical Loss

Search Result 1,444, Processing Time 0.041 seconds

Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System (유리커튼월 수막시스템 분무헤드의 화재 실험 연구)

  • Kim, Sung-Won;Nam, Jiwoo;Cho, Seongwook;Ryou, Hong-Sun;Nam, Jun-Seok;Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, a curtain wall system was applied to skyscrapers to prevent fire spreading along the vertical direction due to stack effect and outside air flow when a fire breaks out in skyscraper. Conventional sprinklers cannot prevent the spread of fire to the upstairs areas, which increases the loss of life and property. In this study, a water curtain nozzle that creates wider water coverage on the surface of glass and can prevent the spread of fire to the upstairs areas was developed. The spray pattern of the water curtain nozzle was compared with that of a sprinkler to determine performance of the water curtain nozzle. A fire experiment was constructed on the second floor to verify performance of the water curtain nozzle in preventing the spread of fire to the upstairs areas. The fire and watering experiment proved that the water curtain nozzle prevented more effectively the spread of fire than the conventional sprinkler. The position of first crack and critical temperature of fracture were also analyzed using numerical analysis.

Potential Welfare Loss from Using Imperfect Environmental Taxes (불완전한 환경세 사용에 따른 잠재적 후생 손실)

  • Hong, Inkee
    • Environmental and Resource Economics Review
    • /
    • v.24 no.1
    • /
    • pp.1-53
    • /
    • 2015
  • In environmental policy areas, a greater use of economic instruments (EIs) has recently been observed in many countries. However, EIs are heterogeneous policy tools. The textbook case of a Pigouvian tax is far from widely used, mainly due to the information requirements and other structural and institutional constraints. The successful implementation of EIs might heavily depend on pre-existing structural and institutional conditions. Moreover, these institutional conditions are particularly unfavorable in developing countries. Using a simple analytical general equilibrium model, this paper examines how these constraints affect the welfare gain from the introduction of environmental taxes in developing countries. First, this paper solves for the second-best optimal Pigouvian tax and output tax in the presence of a distortionary tax on market use of labor. The result confirms that an environmental output tax achieves a socially-efficient level of emissions in the least-cost manner only if the nature of the linkage between the tax base and the environmental damage is fixed. Second, incorporating structural and institutional constraints into the model through a set of parameter values from China and the US, this paper calculates the net welfare effects of either using the ideal Pigouvian tax or instead using an output tax. The numerical simulation results show that the net welfare gain from the use of an ideal Pigouvian tax could be more than six times larger than that of an output tax in developing countries. On the other hand, the welfare gain is only 50 percent in developed countries. This means that the potential welfare disadvantage from using output taxes instead emissions tax for environmental purposes could be much greater in the case of developing countries.

Tunneling-induced Building Damage Risk Assessment System (터널굴착에 따른 인접건물 손상위험도 평가시스템)

  • Park, Yong-Won;Yoon, Hyo-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2002
  • This paper deals with development of a damage risk assessment system for adjacent buildings to under-passing tunnel face considering 3D-ground movement. The system consists of building and ground information module, monitoring data module, settlement evaluation module, and building damage risk assessment module. The major modules, settlement evaluation module and building damage assessment module, are based on settlement estimation model suggested by Attewell et al (1982) and the building damage assessment method by Mair et al. (1996). After estimating 3D-ground movements due to tunneling with settlement evaluation module, damage assessment far buildings is performed using building damage risk assessment module. The developed system has two major functions; 1) calculation of 3D-settlement with ground loss ($V_{s}$)or maximum settlement ($w_{max}$) and inflection point (i) using various empirical formulae, monitoring data, numerical results, and so on; 2) assessment of damage risk for adjacent buildings of arbitrary section with position change of tunnel face. The field data given by Boscadin and Cording (1989) leer the case of two-storied masonry building near the Metro tunnel in Washington D.C. was simulated to verify the applicability of the developed system.

Optimal design of impeller in fan motor unit of cordless vacuum cleaner for improving flow performance and reducing aerodynamic noise (무선진공청소기 팬 모터 단품의 유량성능 향상과 공력소음 저감을 위한 임펠라 최적설계)

  • Kim, KunWoo;Ryu, Seo-Yoon;Cheong, Cheolung;Seo, Seongjin;Jang, Cheolmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.379-389
    • /
    • 2020
  • In this study, the flow and noise performances of high-speed fan motor unit for cordless vacuum cleaner is improved by optimizing the impeller which drives the suction air through flow passage of the cordless vacuum cleaner. Firstly, the unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equations are solved to investigate the flow through the fan motor unit using the computational fluid dynamics techniques. Based on flow field results, the Ffowcs-Williams and Hawkings (FW-H) integral equation is used to predict flow noise radiated from the impeller. Predicted results are compared to the measured ones, which confirms the validity of the numerical method used. It is found that the strong vortex is formed around the mid-chord region of the main blades where the blade curvature change rapidly. Given that vortex acts as a loss for flow and a noise source for noise, impeller blade is redesigned to suppress the identified vortex. The response surface method using two factors is employed to determine the optimum inlet and outlet sweep angles for maximum flow rate and minimum noise. Further analysis of finally selected design confirms the improved flow and noise performance.

A Developmont of Numerical Mo del on the Estimation of the Log-term Run-off for the Design of Riverheads Works -With Special Reference to Small and Medium Sijed Catchment Areas- (제수원공 설계를 위한 장기간 연속수수량 추정모형의 개발 - 중심유역을 중심으로)

  • 엄병현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.4
    • /
    • pp.59-72
    • /
    • 1987
  • Although long-term runoff analysis is important as much as flood analysis in the design of water works, the technological level of the former is relatively lower than that of the latter. In this respect, the precise estimation model for the volume of successive runoff should he developed as soon as possible. Up to now, in Korea, Gajiyama's formula has been widely used in long-term runoff analysis, which has many problems in applying in real situation. On the other hand, in flood analysis, unit hydrograph method has been exclusively used. Therefore, this study aims at trying to apply unit hydrograph method in long-term runoff analysis for the betterment of its estimation. Four test catchment areas were selected ; Maesan area in Namlum river as a representative area of Han river system, Cheongju area in Musim river as one of Geum river system, Hwasun area in Hwasun river as one of Yongsan river system, and Supyung area in Geum river as one of Nakdong river system. In the analysis of unit hydrograph, seperation of effective rainfall was carried out firstly. Considering that effective rainfall and moisture condition of catchrnent area are inside and outside of a phenomenon respectively and the latter is not considered in the analysis, Initial base flow(qb)was selected as an index of moisture condition. At the same time, basic equation(Eq.7) was established, in which qb can take a role as a parameter in relating between cumulative rainfall(P) and cumulative loss of rainfall(Ld). Based on the above equation, computer program for estimation model of qbwas seperately developed according to the range of qb, Developed model was applied to measured hydrographs and hyetographs for total 10 years in 4 test areas and effective rainfall was estimated. Estimation precision of model was checked as shown in Tab- 6 and Fig.8. In the next stage, based on the estimated effective rainfall(R) and runoff(Qd), a runoff distribution ratio was calculated for each teat area using by computerised least square method and used in making unit hydrographs in each test area. Significance of induced hydrographs was tested by checking the relative errors between estimated and measured runoff volume(Tab-9, 10). According to the results, runoff estimation error by unit hydrograph itself was merely 2 or 3 %, but other 2 or 3 % of error proved to be transferred error in the seperation of effective rainfall. In this study, special attentioning point is that, in spite of different river systems and forest conditions of test areas, standardized unit hydrographs for them have very similar curve shape, which can be explained by having similar catchinent characteristics such as stream length, catchinent area, slope, and vegetation intensity. That fact should be treated as important factor ingeneralization of unit hydrograph method.

  • PDF

Abnormal Response Analysis of a Cable-Stayed Bridge using Gradual Bilinear Method (Gradual Bilinear Method를 이용한 사장교의 케이블 손상응답 해석)

  • Kim, Byeong-Cheol;Park, Ki-Tae;Kim, Tae-Heon;Hwang, Ji-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.60-71
    • /
    • 2014
  • Cable-stayed bridge, which is one of the representative long-spanned bridge, needs prompt maintenances when a stay cable is damaged because it may cause structural failure of the entire bridge. Many researches are being conducted to develop abnormal behavior detection algorithms for the purpose of shortening the reaction time after the occurrence of structural damage. To improve the accuracy of the damage detection algorithm, ample observation data from various kinds of damage responses is needed. However, it is difficult to measure an abnormal response by damaging an existing bridge, numerical simulation can be an effective alternative. In most previous studies, which simulate the damage responses of a cable-stayed bridge, the damages has been considered as a load variation without regard to its stiffness variation. The analyses of using these simplification could not calculate exact responses of damaged structure, though it may reserve a sufficient accuracy for the purpose of bridge design. This study suggests Gradual Bilinear Method (GBM) which simulate the damage responses of cable-stayed bridge considering the stiffness and mass variation, and develops an analysis program. The developed program is verified from the responses of a simple model. The responses of a existing cable-stayed bridge model are analyzed with respect to the fracture delay time and damage ratio. The results of this study can be used to develop and verify the highly accurate abnormal behavior detection algorithm for safety management of architecture/large structures.

A Study on the SAR Measurement System Validation at 150 MHz Band (150 MHz 대역에서의 SAR 측정시스템의 유효성 연구)

  • Choi, Donggeun;Kim, Kihwea;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.10
    • /
    • pp.1008-1016
    • /
    • 2013
  • SAR measurement which was applied only to the mobile phone has been expanded in the Korean radio regulation law to the portable wireless communication equipments within 20 cm from the human body since Jan. 2012. The two-way radio operating at 150 MHz frequency band was newly included following the revised radio regulation in the target equipment of measurement. SAR measurement system at 150 MHz satisfying this regulation is necessary accordingly for SAR conformity assessment. The international SAR measurement standard(IEC 62209-2) includes the evaluation method on frequencies above 300 MHz, and the commercial SAR measurement system can measure SAR above 300 MHz only. The size of the reference dipole antenna(760 mm, return loss: -27.57 dB) and flat phantom ($1,300 mm(L){\times}900 mm(W){\times}200 mm(H)$), targeted SAR values for numerical analysis(1 g: 1.08 W/kg, 10 g: 0.77 W/kg) for SAR validation evaluation at 150 MHz frequency are proposed in this paper. The suggested dipole antenna and flat phantom are assembled and used to verify the conformity assessment of commercial SAR measurement system. The measured SAR values of 1 g and 10 g were obtained respectively to be 1.13 W/kg, 0.81 W/kg, and they satisfied the effective range(within ${\pm}10$ %) of IEC international standard. The standards based on this study are expected to be used for the domestic SAR measurement standard and IEC(International Electrotechnical Commission) international standard.

Single Path Phase-only Security System using Phase-encoded XOR Operations in Fourier Plane (푸리에 영역에서의 위상 변조 Exclusive-OR 연산을 이용한 단일 경로 위상 암호화 시스템)

  • Shin, Chang-Mok;Cho, Kyu-Bo;Kim, Soo-Joong;Noh, Duck-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.326-333
    • /
    • 2005
  • Phase-only encryption scheme using exclusive-OR rules in Fourier plane and a single path decryption system are presented. A zero-padded original image, multiplied by a random phase image, is Fourier transformed and its real-valued data is encrypted with key data by using XOR rules. A decryption is simply performed based on 2-1 setup with spatial filter by Fourier transform for multiplying phase-only encrypted data by phase-only key data, which are obtained by phase-encoding process, and spatial filtering for zero-order elimination in inverse-Fourier plane. Since the encryption process is peformed in Fourier plane, proposed encryption scheme is more tolerant to loss of key information by scratching or cutting than previous XOR encryption method in space domain. Compare with previous phase-visualization systems, due to the simple architecture without a reference wave, our system is basically robust to mechanical vibrations and fluctuations. Numerical simulations have confirmed the proposed technique as high-level encryption and simple decryption architecture.

A dual-frequency and dual-polarization antenna with enhanced isolation between two ports using mushroom-like EBGs (버섯모양 EBG를 이용하여 두 포트 사이의 고립도를 향상시킨 이중대역 이중편파 안테나)

  • Lee, Dong-Hyun;Kim, Jae-Hee;Jang, Jong-Hoon;Park, Wee-Sang
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.5
    • /
    • pp.70-75
    • /
    • 2007
  • A dual-frequency dual-polarization (DFDP) antenna with high isolation between two ports by embedding $2{\times}1$ mushroom-like electromagnetic bandgap (EBG) cells is proposed. The equivalent circuit of a suspended microstrip line over $2{\times}1$ EBG cells is introduced. The numerical analysis from the equivalent circuit and measured results show that the microstrip line with embedded EBG cells has a distinctive and sharp rejection band and provides near 0 dB insertion loss outside the rejection band. By embedding the EBG cells under feedlines of a conventional DFDP antenna, the isolation between two ports of the antenna is enhanced more than 20 dB, as compared to that of a conventional DFDP antenna. The proposed DFDP antenna is fabricated and measured. The simulated and measured results show a good agreement. The measured polarization purity and gain of the antenna are 25 dB and 5.77 dBi at lower band, and 35 dB and 7.13 dBi at higher band, respectively.

A Study on the Characteristics of Underwater Sound Transmission by Short-term Variation of Sound Speed Profiles in Shallow-Water Channel with Thermocline (수온약층이 존재하는 천해역에서 단기간 음속구조 변화에 따른 음향 신호 전달 변동에 관한 연구)

  • Jeong, Dong-Yeong;Kim, Sea-Moon;Byun, Sung-Hoon;Lim, Yong-Kon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.20-35
    • /
    • 2015
  • Underwater acoustic channel impulse responses (CIR) are influenced by sound speed profile (SSP), and the variation of CIR has significant effects on the performance of underwater acoustic communication systems. A significant change of SSP can occur within a short period, which must be considered during the design of underwater acoustic modems. This paper statistically analyzes the effect of the variation of SSP on the long-range acoustic signal propagation in shallow-water with thermocline using numerical modeling based on the data acquired from JACE13 experiment near Jeju island. The analysis result shows that CIR changes variously according to the SSP and the depth of the transmitter and receiver. We also found that when the transmitter and receiver are deeper, the variation of sound wave propagation pattern is smaller and signal level becomes higher. All CIR obtained in this study show that a series of bottom reflections due to downward refraction and small bottom loss in the shallow water with thermocline can be very important factor for long-range signal transmission and the performance of underwater acoustic communication system in time varying ocean environment can be very sensitive to the variation of SSP even for a short period of time.