• Title/Summary/Keyword: Numbers of Needling

Search Result 4, Processing Time 0.02 seconds

A Study on the Hemisphere-Type Compression Molding for Continous Fiber-Reinforced Polymeric Composites (연속섬유강화 플라스틱 복합재료의 반구형 압축성형성에 관한 연구)

  • 임용진;오영준;김이곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.149-153
    • /
    • 1999
  • During a hemisphere-type compression molding, the wrinkles are caused by complex stress condition. It is very important to clarify the degree of wrinkles in order to have good products. In this paper, the effects of numbers of needling and initial area on the degree of wrinkles are studied. the degree of wrinkle is expressed as nonhomogeneity.

  • PDF

The Preliminarily Result of Radiologic Disappearance of the Calcific Material on One Time Ultrasonographic Assisted Needling (견관절의 석회화 건염에서 초음파 유도하 1회 주사요법에 의한 방사선학적 조기 소멸 정도에 대한 예비보고)

  • Yoo, Jae-Chul;Shon, Min-Soo;Koh, Kyoung-Hwan;Lim, Tae-Kang;Lee, Yeong-Seok
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose: The purpose of this study is to report the preliminarily result of the radiologic disappearance of the calcific material, regardless of the size, type or location, on one-time ultrasonographic (US) assisted needling for calcific tendinitis of the shoulder. Materials and Methods: From March to August 2011, 46 patients (47 shoulders) with symptomatic calcific tendinitis were treated by one-time US assisted needling. Initially, a diagnostic US was performed with patient to determine the locations, numbers and sizes of calcific deposits. After 1% lidocaine local anesthesia, the calcific material was punctured with an 18-gauge needle under US monitoring. If no calcific material was aspirated after 2 or 3 additional attempts, the deposits was performed multiple puncture to achieve decompression. And then all patients were performed subacromial corticosteroid injection. All patients were followed up 4 weeks after procedure. To assess the radiologic disappearance after one-time US assisted needling, simple radiographs of the treated shoulder were performed and size, dense, and morphology of the calcific deposits were compared with those in baseline radiographs. For clinical evaluations, visual analogue scale for pain and function (PVAS and FVAS), and American Shoulder and Elbow Surgeons (ASES) score were assessed. Results: There were 11 male and 35 female patients with the mean age of 53.8 years (28-71). The morphology of the calcific deposits were 31 type A and 16 type B by French Arthroscopic Society classification and mean size was $2.9{\pm}6.7$ mm before the procedure. At 4 weeks after the index procedure, the radiographic unchanged group was included in 10 cases and changed group was 37 cases. No intergroup difference for the clinical results after the procedure was evident, but group FAS classification before the procedure was significantly different (p=0.011). Conclusion: At 4 weeks after one-time US assisted needling for calcific tendinitis of the shoulder, the radiographic size- or dense-changed cases were showed in 79%, regardless of the size, type or location of the calcific material. But the radiographic nearly or complete disappearance were showed in only 21%.

  • PDF

A Study on the Meaning of Theory that Acupuncture has no Reinforcement -Focusing on the method of reinforcement and reduction in Huangdineijing- (침무보법(鍼無補法)의 의미에 대한 고찰(考察) -『황제내경(黃帝內經)』의 보사법(補瀉法)을 중심으로-)

  • Yun, Ki-ryoung;Baik, Yousang;Jang, Woo-chang;Jeong, Chang-hyun
    • Journal of Korean Medical classics
    • /
    • v.31 no.2
    • /
    • pp.141-153
    • /
    • 2018
  • Objectives : Acupuncture therapy's reinforcement and reduction method is now widely used in the clinical practices. Meanwhile, there has been a voice of concern since the past that acupuncture has no reinforcement. This thought has not been given enough discussion, and the paper attempts to remedy this absence and verify the validity of the concern. Methods : The acupunctural reinforcement and reduction method found in the Huangdineijing is reviewed, and a number of medical books that discuss the idea of lack of reinforcement in acupuncture are studied. Results : Huangdineijing describes the acupunctural unique feature of reduction. The text explains that acupuncture work in a way that is different that medicine, and thus cannot be used for a disease based on deficiency. In addition, it warned the loss of the primordial qi when needling oneself. Reinforcement in the reinforcement and reduction technique as described in Huangdineijing mainly revolves around preventing the loss of the primordial qi. Conclusions : The purpose of the acupunctural reinforcement and reduction is to control the body's disproportional qi deficiency and excess, where some parts of the body has more qi than others. The reinforcement in "acupunctural reinforcement and reduction method" and the reinforcement in "acupuncture only has reduction and no reinforcement" within the thought of "acupuncture has no reinforcement" are different in that one deals with controlling the imbalance of qi in body, and the other deals with dispelling the deficiency by flowing the qi in the viewpoint of entering and out. This calls for a need to establish the proper acupunctural points, numbers, and times for each disease based on the theory of "acupuncture has no reinforcemen."

A Study on the Compression Moldablity for Continuous Fiber-Reinforced Polymeric Composites ―Part 1 : The Mechanical Propertis and the Cup-type Compression Moldability for Numbers of Needling― (연속섬유강화 플라스틱 복합재료의 압축성형에 관한 연구 -제I보 : 니들펀칭횟수에 따른 물성치 및 컵형 압축성형성-)

  • 오영준;김형철;김이곤
    • Composites Research
    • /
    • v.12 no.5
    • /
    • pp.31-39
    • /
    • 1999
  • Glass-fiber reinforced polymeric composites provide the desitable properties of high stiffness and strength as well as specific weight. Hence, they have become some of the most important materials in several industries. These composites can be grouped into thermoplastic and thermoset composites, with thermoplastic composites having several advantages over thermoset composites in mechanical properties and processing. As a result, the study of the material behavior and forming techniques of such composites has attracted considerable attention in recent years. When the continuous fiber-reinforced polymeric composites are molded by flow molding, the molded parts leads to be nonhomogeneity and anisotropic because of the separation and orientation of fibers. As the characteristics of the products are greatly dependent on the separation, it is very important to clarify the separation in relarion to molding conditions, fiber mat structures and mold geometry. In this study, the effects of the mold geometry and the fiber mat structure on the compression moldability are studied using the cup-type molding.

  • PDF