• 제목/요약/키워드: Number of radiographs

검색결과 122건 처리시간 0.027초

X-ray 영상에서 SegNet을 이용한 폐결핵 자동검출 시스템의 유용성 평가 (Evaluation on the Usefulness of X-ray Computer-Aided Detection (CAD) System for Pulmonary Tuberculosis (PTB) using SegNet)

  • 이주희;안현수;최동혁;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권1호
    • /
    • pp.25-31
    • /
    • 2017
  • Testing TB in chest X-ray images is a typical method to diagnose presence and magnitude of PTB lesion. However, the method has limitation due to inter-reader variability. Therefore, it is essential to overcome this drawback with automatic interpretation. In this study, we propose a novel method for detection of PTB using SegNet, which is a deep learning architecture for semantic pixel wise image labelling. SegNet is composed of a stack of encoders followed by a corresponding decoder stack which feeds into a soft-max classification layer. We modified parameters of SegNet to change the number of classes from 12 to 2 (TB or none-TB) and applied the architecture to automatically interpret chest radiographs. 552 chest X-ray images, provided by The Korean Institute of Tuberculosis, used for training and test and we constructed a receiver operating characteristic (ROC) curve. As a consequence, the area under the curve (AUC) was 90.4% (95% CI:[85.1, 95.7]) with a classification accuracy of 84.3%. A sensitivity was 85.7% and specificity was 82.8% on 431 training images (TB 172, none-TB 259) and 121 test images (TB 63, none-TB 58). This results show that detecting PTB using SegNet is comparable to other PTB detection methods.

개의 비강샘암종 증례 (Nasal adenocarcinoma in a dog)

  • 윤정식;정지열;조숙희;김재훈;우계형;전재남;김재훈
    • 대한수의학회지
    • /
    • 제49권1호
    • /
    • pp.67-71
    • /
    • 2009
  • A 10-year old female Yorkshire terrier with nasal discharge and swelling was referred to the local animal hospital. Abnormal mass of right nasal cavity was detected in physical examination and radiography. According to the radiographs of the head, there was an evidence of bony destruction in right nose. Oronasal fistula was detected in right maxillary canine teeth. After surgical excision, the sample of nasal mass was refereed to Pathology Department of Veterinary Medicine in Jeju National University. Grossly, the enlarged mass was soft and 3 ${\times}$ 3 cm in size. Histopathologically, the neoplastic mass was composed of tubular to tubulopapillary structures which were lined by single to 6~7 layers of cuboidal to ciliated columnar cells. These neoplastic cells showed invasive tendency to adjacent normal parenchyma. They had uniform, round to oval nuclei, cytoplasm with small vacuoles and indistinct cellular margin. The number of mitotic figures was varied in different areas, ranged from 0 to 4 per high power field. Necrotic foci and infiltration of inflammatory cells including neutrophils, lymphocytes, and plasma cells also presented in the mass. Immunohistochemically, the neoplastic cells demonstrated strong positive reaction for cytokeratin (CK) 18 but were negative for CK 7 and 8. Based on the gross, histopathology and immunohistochemistry, this mass was diagnosed as nasal adenocarcinoma originated from respiratory epithelium.

Postoperative Flat Back : Contribution of Posterior Accessed Lumbar Interbody Fusion and Spinopelvic Parameters

  • Kim, Jin Kwon;Moon, Byung Gwan;Kim, Deok Ryeng;Kim, Joo Seung
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권4호
    • /
    • pp.315-322
    • /
    • 2014
  • Objective : Posterior accessed lumbar interbody fusion (PALIF) has a clear objective to restore disc height and spinal alignment but surgeons may occasionally face the converse situation and lose lumbar lordosis. We analyzed retrospective data for factors contributing to a postoperative flat back. Methods : A total of 105 patients who underwent PALIF for spondylolisthesis and stenosis were enrolled. The patients were divided according to surgical type [posterior lumbar inter body fusion (PLIF) vs. unilateral transforaminal lumbar interbody fusion (TLIF)], number of levels (single vs. multiple), and diagnosis (spondylolisthesis vs. stenosis). We measured perioperative index level lordosis, lumbar lordosis, pelvic tilt, sacral slope, pelvic incidence, and disc height in standing lateral radiographs. The change and variance in each parameter and comparative group were analyzed with the paired and Student t-test (p<0.05), correlation coefficient, and regression analysis. Results : A significant perioperative reduction was observed in index-level lordosis following TLIF at the single level and in patients with spondylolisthesis (p=0.002, p=0.005). Pelvic tilt and sacral slope were significantly restored following PLIF multilevel surgery (p=0.009, p=0.003). Sacral slope variance was highly sensitive to perioperative variance of index level lordosis in high sacral sloped pelvis. Perioperative variance of index level lordosis was positively correlated with disc height variance ($R^2=0.286$, p=0.0005). Conclusion : Unilateral TLIF has the potential to cause postoperative flat back. PLIF is more reliable than unilateral TLIF to restore spinopelvic parameters following multilevel surgery and spondylolisthesis. A high sacral sloped pelvis is more vulnerable to PALIF in terms of a postoperative flat back.

Peri-implant bone length changes and survival rates of implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height

  • Kim, Hae-Young;Yang, Jin-Yong;Chung, Bo-Yoon;Kim, Jeong Chan;Yeo, In-Sung
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.58-63
    • /
    • 2013
  • Purpose: The aim of this study was to measure the peri-implant bone length surrounding implants that penetrate the sinus membrane at the posterior maxilla and to evaluate the survival rate of these implants. Methods: Treatment records and orthopantomographs of 39 patients were reviewed and analyzed. The patients had partial edentulism at the posterior maxilla and limited vertical bone height below the maxillary sinus. Implants were inserted into the posterior maxilla, penetrating the sinus membrane. Four months after implant insertion, provisional resin restorations were temporarily cemented to the abutments and used for one month. Then, a final impression was taken at the abutment level, and final cement-retained restorations were delivered with mutually protected occlusion. The complications from the implant surgery were examined, the number of failed implants was counted, and the survival rate was calculated. The periimplant bone lengths were measured using radiographs. The changes in initial and final peri-implant bone lengths were statistically analyzed. Results: Nasal bleeding occurred after implant surgery in three patients. No other complications were found. There were no failures of the investigated implants, resulting in a survival rate of 100%. Significantly more bone gain around the implants (estimated difference=-0.6 mm, P=0.025) occurred when the initial residual bone height was less than 5 mm compared to the >5 mm groups. No significant change in peri-implant bone length was detected when the initial residual bone height was 5 mm or larger. Conclusions: This study suggests that implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height may be safe and functional.

근위 갈매기 절골술 시행 전과 후의 원위 중족골 관절면각의 측정에 대한 신뢰성의 변화 (Change of Reliability for Distal Metatarsal Articular Angle Measurement before and after Proximal Chevron Osteotomy)

  • 박철현;이동열
    • 대한족부족관절학회지
    • /
    • 제20권4호
    • /
    • pp.145-151
    • /
    • 2016
  • Purpose: To evaluate the reliability of preoperative and postoperative distal metatarsal articular angle (DMAA) measurements and to determine whether such reliability is different in accordance with the foot and ankle fellowship and the number of years in practice. Materials and Methods: Between July 2012 and June 2014, a total of 20 patients (24 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic hallux valgus deformity. DMAA were measured twice with an interval of two weeks between the preoperative and postoperative dorsoplantar radiographs by four observers; two of whom were foot and ankle surgeons (A and B), one knee surgeon, and one senior resident. The intraobserver reproducibility and interobserver reliability were assessed by intraclass correlation coefficients. Moreover, the limit of agreement between the preoperative and postoperative DMAA measurements were assessed using a Bland-Altman plot. Results: The intraobserver reproducibility of the foot and ankle surgeon A, knee surgeon, and senior resident improved from 0.796, 0.575, and 0.586 preoperatively to 0.968, 0.864, and 0.864 postoperatively, respectively. The interobserver reliability of foot and ankle surgeon A-B, foot and ankle surgeon A-knee surgeon, and foot and ankle surgeon A-senior resident improved from 0.874, 0.688, and 0.677 preoperatively to 0.971, 0.917, and 0.838 postoperatively, respectively. Conclusion: The intra- and interobserver reliabilities for DMAA measurement improved after proximal chevron osteotomy. Therefore, the necessity of additional procedures to correct the increased DMAA should be reevaluated after proximal chevron osteotomy in the hallux valgus with an increased DMAA.

A Comparative Study of Nursing Home-Acquired Pneumonia with Community-Acquired Pneumonia

  • Cho, Young-Jae;Jung, Bong-Ki;Ahn, Joon-Seok
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권3호
    • /
    • pp.224-234
    • /
    • 2011
  • Background: Little data is available regarding hospitalized patients with nursing home-acquired pneumonia (NHAP). This is unfortunate because there is an increasing number of elderly persons who are living in nursing homes in Korea. The aim of this study was to compare clinical characteristics and treatment responses of NHAP with community-acquired pneumonia (CAP). Methods: Patients with pneumonia who were admitted from eight nursing homes or from their own homes were enrolled between May 2007 and April 2009. Their clinical characteristics and treatment responses were reviewed retrospectively, and differences between the two groups were analyzed. Results: Of 110 Patients with pneumonia, 66 (60%) were from nursing homes and their median age was 84. In the NHAP group, functional performance status was significantly poorer, classical symptoms of pneumonia were less severe, and multi-lobe involvement (on chest radiographs) was more frequent than in the CAP group. Patients with NHAP more frequently showed lymphocytopenia, anemia, hypoalbuminemia, hypoxemia, and elevated blood urea nitrogen on admission. The mean CURB-65 score was 2.2 in the NHAP group, higher than 1.7 in the CAP group (p=0.004), and multi-drug resistant pathogens were also highly identified in NHAP group (39% vs. 10%, p=0.036). The mean duration of antibiotic therapy was greater for the NHAP (12.6 days) than for the CAP group (6.6 days) (p<0.001). The mortality rate was 23% in NHAP group, which was significantly higher than 5% in the CAP group (p=0.014). Conclusion: NHAP should be more intensively investigated because of the higher frequency of multi-drug resistant pathogens and mortality than the CAP.

Verification of Microstructure Qualities of ACR-Approved Mammography Phantoms by Refraction-Enhanced Synchrotron Radiation Imaging

  • Imamura, Keiko;Ehara, Norishige;Inada, Yoichi;Miyamoto, Keiko;Kanemaki, Yoshihide;Umetani, Keiji;Uesugi, Kentaro;Ochiai, Yoshinori;Fukuda, Mamoru;Nakajima, Yasuo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.415-417
    • /
    • 2002
  • Images of microcalcification specks showed large variation in conventional radiographs of phantoms which are approved for mammography image quality standard by the American College of Radiology (ACR). This kind of variation is not appropriate for image quality standards because the number of specks are visually counted in images and that number is important in image quality evaluation. Our study using synchrotron radiation (SR) imaging revealed the overlapping of micro-sized air bubble(s) to some specks, and also the structural deformation or crackings. Eight phantoms approved by ACR from two different makers and an air-bubble phantom were examined. SR imaging was performed at a synchrotron radiation facility, SPring-8, in Japan. The image-detector was a fluorescent-screen optical-lens coupling system using a CCD camera with a spatial resolution of 6 $\square$m. Objects when imaged with longer sample-to-detector distance show edge enhancement due to a difference in refraction indices, that is refraction enhancement. Refraction-enhanced SR images revealed that some of specks carried foreign objects, which were proven to be air. In phantoms provided by one maker, attaching/overlapping airs were observed for 62 out of 150 specks (41%) , with a higher incidence for the smallest specks. A speck becomes hardly visible in a conventional radiograph when air(s) overlaps the majority part of a speck, though depending on the size of the air-inclusion and on its configuration. Those airs might have been adsorbed on a speck surface before being embedded and then introduced into the matrix together with specks. Our study using SR imaging has clearly shown the nature of defects in some mammography phantoms which seriously degrade the quality as an image standard.

  • PDF

Contrast reference values in panoramic radiographic images using an arch-form phantom stand

  • Shin, Jae-Myung;Lee, Chena;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제46권3호
    • /
    • pp.203-210
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. Materials and Methods: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. Results: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. Conclusion: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images.

대구치에서 회전식 NiTi file의 수명과 파절양상 (LIFETIME AND FRACTURE PATTERNS OF NITI ROTARY FILES IN MOLARS)

  • 김진우;안병두;박세희;신혜진;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제30권3호
    • /
    • pp.184-192
    • /
    • 2005
  • 회전식 NiTi file은쉽게 파절되는 단점이 있으나 이에 대한 연구는 아직 부족하다. 본 연구에서는 회전식 NiTi file을 이용해 실제 치아에서 근관을 형성하고, 이 때 발생하는 파절 및 변형을 연구, 분석하였다. 상악 대구치의 근심협측 치근 (n = 150)과 하악 대구치의 근심치근 (n = 150)을 실험대상으로 하여 Profile, ProTaper 및 K3로 각각 근관형성 하였다. 각 file은 파절되거나 변형이 생길 때까지 계속하여 사용한 다음 그 사용횟수를 기록하였다. 파절의 양상을 관찰하기 위해 방사선 및 주사현미경 사진을 촬영하였다. 1 세 군간의 유의할만한 사용횟수의 차이는 없었다. 2. Flaring file 간의 비교에서는 K3의 사용횟수가 통계적으로 유의성 있게 적었으며 (p < 0.05), shaping file 간에는 유의할만한 차이가 없었다. 3, 회전식 NiTi file의 파절은 근관의 최대 만곡부에서 발생하였다. 4. 주사전자현미경으로 파절면을 관찰한 결과 연성파괴의 전형적인 양상인 얕은 딤플이 관찰되었다. 일반적으로 회전식 NiTi file의 평균 사용횟수는 제조회사의 사용지침보다는 길었으며, NiTi file의 수명에 대한 새로운 사용지침을 만들기 위한 부가적인 연구가 있어야 되리라 사료된다.

골다공증과 악골의 골밀도 및 치주 질환과의 상관 관계 (Relationships between osteoporosis, alveolar bone density and periodontal disease in postmenopausal women)

  • 한은영;류인철;이용무;구영;한수부;최상묵;신지연;양승민;정종평
    • Journal of Periodontal and Implant Science
    • /
    • 제31권3호
    • /
    • pp.565-571
    • /
    • 2001
  • The purpose of this study is to determine if a relationship exists among osteoporosis, alveolar bone density and periodontal disease in postmenopausal osteoporotic women and postmenopausal healthy women. Twenty-two women were evaluated for this study. They were attending the postmenopausal clinic, Seoul National University Hospital and generally healthy except osteoporosis. They had experienced menopause not less than one year when we began to examine them. Bone densities of lumbar area(L2-L4) was determined by DEXA(LUNAR-expert Co,. U.S.A). We diagnosed osteoporosis when T-score was below -2.5 and healthy state when T-score was over -1. Osteoporotic(10 female), not hormone-treated group and healthy control group(12 female) were asked for their age, menopausal age, menopausal period and the number of remaining teeth and examined clinically for plaque index(PI), gingival index(GI), clinical attachment loss(CAL) on their 6 Ramfjord index teeth. Intraoral radiographs were taken in maxillary anterior zone. All films were equally exposed and developed. Each films was digitized and analysed using image processing software, Scion image. Alveolar bone regions of interest were selected and Intensity of each pixel was quantized in the array ranging from 0(white) to 255(black). The two groups were comparable with respect age, menopausal age, menopausal period and number of remaining teeth. The osteoporotic women had significantly lower alveolar bone density than controls in maxilla. But no significant difference was found with respect clinical attachment loss, plaque index and gingival index. Supported by the Ministry of Public Health and Welfare, Korea (HMP-00-CH-10-0009).

  • PDF