• Title/Summary/Keyword: Number concentration

Search Result 4,028, Processing Time 0.026 seconds

Understanding on Regional Characteristics of Particular Matter in Seoul - Distribution of Concentration in Borough Spatial Area and Relation with the Number of Registered Vehicles - (서울시 미세먼지 농도의 지역적 특성파악을 위한 연구 - 구별 분포 특성 및 차량등록대수와의 관계 -)

  • Park, Jong-Kil;Choi, Yun-Jeong;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.26 no.1
    • /
    • pp.55-65
    • /
    • 2017
  • Average concentration of PM in Seoul metropolitan area satisfied the Korean air quality standard in 2010. Furthermore, concentration of PM in all boroughs across Seoul met the air environment standard in 2012. $PM_{10}$ concentration was relatively higher in center of Seoul in comparison to the rest, while $PM_{2.5}$ concentration showed exactly the contrary result. We analyzed the effect that PM emissions from vehicles would have on PM concentrations across Seoul. The results showed that average annual PM concentration recently decreased in Seoul although the number of vehicles registered annually continued its upward trend. By contrast, average fine dust concentrations in Seoul showed a decline which suggested that correlation between annual average PM concentrations and number of registered vehicles remained low. However, year-on-year vehicle registration rate recently showed a declining tendency in the same way as the trend of changes in average PM concentrations. Particularly, the upward trend in annual average PM concentrations in 2002 and 2007 was consistent with the increase in vehicle registration rate, suggesting that vehicle registration rate was closely associated with changes in PM concentrations.

REYNOLDS NUMBER EFFECTS ON MASS TRANSFER IN TURBULENT PIPE FLOW: PART I. MEAN CONCENTRATION FIELD AND LOW-ORDER STATISTICS (난류 파이프 유동 내 물질전달에 대한 레이놀즈 수 영향: Part I. 평균 농도장 및 저차 난류통계치)

  • Kang, Chang-Woo;Yang, Kyung-Soo
    • Journal of computational fluids engineering
    • /
    • v.17 no.3
    • /
    • pp.1-10
    • /
    • 2012
  • Large Eddy Simulation(LES) of turbulent mass transfer in fully developed turbulent pipe flow has been performed to study the effect of Reynolds number on the concentration fields at $Re_{\tau}=180$, 395, 590 based on friction velocity and pipe radius. Dynamic subgrid-scale models for the turbulent subgrid-scale stresses and mass fluxes were employed to close the governing equations. Fully developed turbulent pipe flows with constant mass flux imposed at the wall are studied for Sc=0.71. The mean concentration profiles and turbulent intensities obtained from the present LES are in good agreement with the previous numerical and experimental results currently available. To show the effects of Reynolds number on the turbulent mass transfer, the mean concentration profile, root-mean-square of concentration fluctuations, turbulent mass fluxes, cross-correlation coefficient, turbulent diffusivity and turbulent Schmidt number are presented.

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • 최우석;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

Trends and Factors of Ozone Concentration Variations in Korea (우리나라의 오존도 변화 추이와 주요 인자)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.607-623
    • /
    • 2000
  • Major trends of ozone concentration variations in Korea were investigated by using observation data from around 100 stations for the period of 1991∼1997. In addition, important regulating those variations were inferred. Three measures such as the number of days exceeding 80ppb, the 95th percentile of daily maxima, and the annual average concentration were used for the analysis of multi-scale ozone concentration variations. Three areas in the southwest (Sosan, Mokpo, and Cheju) of which monitoring has been operated since 1995 showed the highest annual average concentrations over; this was noted because of the high annual average in the Yosu area in the early 1990s. Large increases in annual average concentrations were observed along the relatively cleaner areas connecting Kangnung and Kwangju(northeast to southwest), in contrast to polluted areas connecting Seoul and Pusan(northeast to southeast). Both the number of exceedance days and the daily maximum concentration were nearly constant in the Greater Seoul Area in spite of interannual flucturations associated with year-to-year changes in air temperature. Within the Greater Seoul Area, all three measures usually showed the same trend; they decreased in the middle and west and increased in the east and northeast. All three measures including the number of exceedance days increased largely at Sillim where the average concentration was high but no exceedance days were recorded in the early 1999s, Nationwide ozone concentration variations appear to be determined by the competitive influence of long-range transport and local urban emissions, Within the city including the Greater Seoul Area, changes in emission which accompany changes in population and in the number if vehicles ( in the process of urban development) were found to be important components of ozone concentration variations.

  • PDF

Improvement and Observation of Condensation Particle Counter in Atmospheric Research Aircraft NARA for Condensation Particle Research in Korea (한반도 상공의 응결핵 연구를 위한 기상항공기 나라호의 응결핵입자계수기 개선 및 관측)

  • Jung, Woonseon;Ku, Jung Mo;Kim, Min-Seong;Shin, Hye-min;Ko, A-Reum;Chang, Ki-Ho;Cha, Joo Wan;Lee, Yong Hee
    • Journal of Environmental Science International
    • /
    • v.31 no.9
    • /
    • pp.803-813
    • /
    • 2022
  • In this study, we improved the water-based condensation particle counter in Atmospheric Research Aircraft NARA and investigated the condensation particle number concentration over the Korean peninsula. Pump and set point information were changed to improve the instrument used by aircraft for observation. Ground-based observational result showed that the error between two instruments, which are water-based condensation particle counter and butanol-based condensation particle counter, was 4.7%. Aerial observational result revealed that the number concentration before improvement indicate large variation with unstable condition, whereas the number concentration after improvement indicate a reasonable variation. After improvement, the number concentration was 706±499 particle/cm3 in the West Sea and 257±80 particle/cm3 in Gangwon-do, and these are similar to the concentration range reported in previous studies. Notably, this is the first attempt to use aerial observation with water-based condensation particle counter to investigate condensation particle number concentration.

Studies on the Tin Content for Fruit Tinplated Can (과실 통조림의 주석 함량에 관한 연구)

  • 허윤행;김옥경;김정헌
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.149-154
    • /
    • 1993
  • Authors investigated on the content of tin metals in 108 samples of tinplated canned fruit commercial. 1. The highest concentration of tin in 11 kinds of samples of canned fruit that is, apricot nectar was 114ppm and lowest of that 2.5∼3ppm. 2. There was 48.6ppm of tin content in orange nectar A that of pineapple nectar 56.6ppm in higher remarkably and that of the other samples was no appearance difference. 3. There was 114ppm(number 10), 5.3∼56.6ppm(number 8) and 8.7∼48.6ppm(number 3) of tin content in minimum between maximum concentration for difference remarkably and that of others there was no difference considerably, The highest concentration in detection frequency of content range was 8∼ 14ppm in 41. 7% and 2.5"6.6ppm in 36.1% and that of concentration was lower for comparison the others. 5. There was lower contration of tin in all samples for law of food hygiene in limitation 150ppm.

  • PDF

Effect of Oxygen Enriched Air on the Combustion of a Turbulent Diffusion Flat Flame (산소부화공기가 난류 확산 평면화염의 연소에 미치는 영향)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • Combustion using oxygen enriched air is an energy saving technology that can increase thermal efficiency by the improvement of burning rate and by the high temperature flame. Flame figures, OH radical intensities, temperature distributions and emission concentrations were measured according to oxygen enriched concentration and swirl number in a turbulent diffusion flat flame. It appeared that flame figure became flat and NO concentration decreased with increase of swirl number, and that the flame temperature increased high with increase of oxygen enriched concentration. In particular, it was most significant between oxygen concentration $40{\sim}60%$.

  • PDF

A Study of the Characteristics of Flow and the Distribution of $CO_2$ Agent Concentration According to the Number of $CO_2$ Agent Nozzle ($CO_2$소화제 노즐수에 따른 유동특성 및 소화제농도분포에 대한 연구)

  • Park Chan-Su
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.37-44
    • /
    • 2005
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the characteristics of flow and the distribution of $CO_2$ agent concentration according to the number of $CO_2$ agent nozzle. The engine room of a ship was selected as a protection space, and flow fields and $CO_2$ concentration fields were measured. In case of increasing the number of $CO_2$ nozzle from 2 nozzles to 4 nozzles, the distribution of CO2 concentration showed low, and in case of increasing the number of $CO_2$ nozzle to above 6 nozzles, the recirculating flow affected to all region was generated. In case of increasing the number of $CO_2$ agent nozzle to above 4 nozzles, the iso-concentration line below 0.36 expanded or contracted slightly. Therefor, the proper number and the arrangement of $CO_2$ agent nozzle are considered when $CO_2$ fire fighting system is designed.

Double-Diffusive Convection in a Salt-Stratified Fluid Heated From Below (농도 성층화된 유체의 아랫면 가열에 의한 이중확산대류에 관한 연구)

  • 강신형;김무현;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3297-3304
    • /
    • 1994
  • Experimental investigation have been made to study the double-diffusive nature of convection of an initially stratified salt-water solution heated from below in a cylindrical cavity. The objective is to examine the process of mixed-layer formation, the flow phenomena, the heat transfer characteristics, and temperature and concentration distribution according to the changes in the effective Rayleigh number based on the reference height which represents the relation of temperature and concentration gradient. The types of initially formed flow pattern are categorized in three regimes depending on the effective Rayleigh number ; stagnant flow regime, single mixed-layer flow regime and successively formed multiple mixed-layer flow regime. The temperature and concentration profiles are both uniform in each layer due to convective mixing in the layered flow regime, but both linear in stagnant flow regime and single mixed-layer flow regime. At the interface between adjacent layers, the temperature changes smoothly but the concentration changes rapidly. The layers expand by diffusion of concentration through the interface along with its random fluctuation.

Culture Condition of Entomopathogenic Nematodes Using Galleria mellonella Larva (Galleria mellonella 유충을 이용한 곤충병원성 선충의 배양 조건)

  • 김도완;박선호
    • KSBB Journal
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 1998
  • A simple method for the in vivo production of third-stage infective juveniles(IJs) of Steinernema glaseri was developed. Using Galleria mellonella larvae, only IJs can be rapidly generated inadequate quantities for field application. The nematode inoculation concentration and incubation temperature were critically important. The most effective temperature for infectivity of Steinernema glaseri IJs to Galleria mellonella larvae was 33$^\circ C$. However, the total number of menatodes harvested at 25$^\circ C$ about 66,000 IJs per larva was significantly greater than those at other temperatures. The optimal inoculation number of nematodes was 60 to 80 nematodes per host larva. The higher nematode inoculation concentration of 100 IJs per larva caused a rapid decrease in the total number of IJs harvested. As the inoculation medium pH increased, the number of IJs harvested increased and reached about 110,000 IJs per larva at pH 9.0. The pathogenicity of IJs decreased y increasing the salt concentration in the medium.

  • PDF